Page 51

SECTION C

COMMUNICATIONS

* Enable RS-232

Load Keyboard Wedge Defaults

³

4

1

5

5

5

4

³

9

9

9

9

9

4

The scanner will work with RS-232 ±12V serial output.

Scan this before selecting Normal or Stand Alone Mode.

Enable Light Pen/Wand Communication

Enable Keyboard Wedge Emulation

³

³

4

1

5

5

2

4

Enable Stand-Alone Keyboard Scanner

5

1

5

5

1

5

1

5

5

1

4

3

Select if the scanner provides keyboard emulation by converting the scanned bar code data to the PC keyboard scan code equivalent.

Use this option if a scanner is used in place of a light pen.

³

5

3

Allows the scanner to be used without an external keyboard. Communications

C

1

Page 52

Communications

C

2

SECTION C

COMMUNICATIONS

Load OCIA Defaults

Enable OCIA Output

³

9

9

9

9

9

3

³

4

1

5

5

4

4

Scan this before selecting Enable OCIA output.

Select this option if the communications requirement is an Optically Coupled Interface Adapter (OCIA). This is a docked (by the host) serial interface.

Load IBM 46xx Defaults

Enable IBM 46xx Communication

³

9

9

9

9

9

5

Scan this before selecting Enable IBM 46xx Communication

³

4

1

5

5

0

4

Select this option for IBM 46xx SIOC/RS485 communications. Not all scanners support this interface. The correct interface board is required.

Page 53

SECTION C

COMMUNICATIONS

Load Low Speed External USB Defaults †

Enable Low Speed USB † † Refer to Section P for full speed USB options.

³

9

9

9

9

7

³

8

4

1

5

5

1

1

Load Low Speed Internal USB Defaults †

Enable No Communication Mode

³

³

9

9

9

9

4

1

4

1

5

5

3

4

4

Select this option if the scanner does not interface with the host device.

Reserved

³

4

1

Reserved

5

5

6

4

³

Communications

C

3

9

1

7

5

0

0

Page 54

This page is a scan with no text; see it in the PDF.

Page 55

SECTION D

CONFIGURATION MODE OPTIONS

Allow Configuration Mode on Power-Up

* Allow Configuration Mode Anytime

³

³

1

1

8

1

1

7

1

1

8

1

0

7

The scanner can only enter MetroSet® mode before any bar codes are scanned.

Allow MetroSet® configuration at any time.

Allow Configuration Codes on Power Up

* Allow Configuration Codes Anytime

³

³

1

1

8

1

1

6

1

1

8

1

0

6

Once a product bar code is scanned after power-up, the scanner will not accept configuration bar codes.

Allows scanning of configuration bar codes any time.

Enable Single Code Configuration

Disable Single Code Configuration

³

³

1

1

8

2

1

2

Scanner Operation

D

1

1

1

8

2

0

2

Page 56

Scanner Operation

D

2

SECTION D

SCAN BUFFERS

* 1 Scan Buffer

³

3

1

8

0

2 Scan Buffers

0

0

³

3

1

8

0

1

0

The scanner will scan one bar code in the scan field and not scan again until the bar code is removed from the scan field for the duration of the same symbol time out.

The scanner will scan 2 bar codes in the scan field one time each. These 2 bar codes will not be scanned again until they are removed from the scan field for the duration of the same symbol time out.

3 Scan Buffers

4 Scan Buffers

³

3

1

8

0

2

0

Same function as 2 Scan Buffers, but 3 bar codes are in the scan field.

³

3

1

8

0

3

0

Same function as 2 Scan Buffers, but 4 bar codes are in the scan field.

Page 57

SECTION D

SCAN BUFFERS

5 Scan Buffers

³

3

1

8

6 Scan Buffers

0

4

0

³

3

1

8

0

5

0

Same function as 2 Scan Buffers, but 5 bar codes are in the scan field.

Same function as 2 Scan Buffers, but 6 bar codes are in the scan field.

7 Scan Buffers

8 Scan Buffers

³

3

1

8

0

6

0

³

Same function as 2 Scan Buffers, but 7 bar codes are in the scan field.

3

1

8

0

7

0

Same function as 2 Scan Buffers, but 8 bar codes are in the scan field.

Scanner Operation

D

3

Page 58

Scanner Operation

D

4

SECTION D

REDUNDANT SCANS

* 0 Redundant Scans

1 Redundant Scans

³

3

0

1

1

0

0

³

3

0

1

1

1

0

Requires 1 good decode for a “good scan”.

Requires 2 consecutive decodes of the same bar code data for a “good scan”.

2 Redundant Scans

3 Redundant Scans

³

3

0

1

1

2

0

Requires 3 consecutive decodes of the same bar code data for a “good scan”.

³

3

0

1

1

3

0

Requires 4 consecutive decodes of the same bar code data for a “good scan”.

Page 59

SECTION D

REDUNDANT SCANS

4 Redundant Scans

5 Redundant Scans

³

3

0

1

1

4

0

³

3

0

1

1

5

0

Requires 5 consecutive decodes of the same bar code data for a “good scan”.

Requires 6 consecutive decodes of the same bar code data for a “good scan”.

6 Redundant Scans

7 Redundant Scans

³

3

0

1

1

6

0

³

Requires 7 consecutive decodes of the same bar code data for a “good scan”.

3

0

1

1

7

0

Requires 8 consecutive decodes of the same bar code data for a “good scan”.

Scanner Operation

D

5

Page 60

Scanner Operation

SECTION D

1

0

1

1

6

MISCELLANEOUS DECODE FEATURES

* Enable Segmented UPC Decoding

³

D

1

Disable Segmented UPC Decoding

3

³

1

0

1

1

0

3

Enabling segmented UPC decoding aids in deciphering damaged or incomplete bar codes.

Disable this feature when bar codes are in good reading condition. This will speed up decoding and improve over all accuracy.

Optional Same Symbol Check

* Normal Same Symbol Check

³

1

1

8

1

1

3

Requires 1 different character between successive bar codes to consider the bar code “new”.

³

1

1

8

1

0

3

Requires 3 different characters between successive bar codes to consider the bar code “new”.