The text of a manual · part 18 of 20
MetroSelect Configuration Guide, pages 171 to 180
Pages 171 to 180 of 200
The original document is the PDF (1.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic QuantumE IS3480
Page 171
SECTION N
CUSTOM DEFAULTS
German Post Defaults
³
8 4 6 6 0 0 9 0
Scan this code followed by the “Recall Defaults” code to enable and load German Post Defaults.
Custom Keyboard FR1
³
9
9
Custom Terminal FR1
³
9
9
7
0
0
1
Miscellaneous Features
N
3
7
0
0
0
Page 172
Miscellaneous Features
SECTION N
4
N
SERIAL PROGRAM MODE
For Serial Program Mode, all commands must be framed by an STX (02 Hex) and ETX (03 Hex). To recall defaults: 1.
Transmit <STX>999999<ETX> through the Serial Port. This will put the scanner in serial program mode. Scanning will be suspended and the scanner will respond with an ACK (06 Hex).
2.
Transmit <STX>999998<ETX> through the Serial Port. This is the Recall Default bar code in the MetroSelect guide. The scanner will respond with an ACK (06 Hex).
3.
Transmit <STX>999999<ETX> through the Serial Port. This will cause the scanner to exit program mode and save the new settings. The scanner will beep 3 times and send an ACK (06 Hex).
If at anytime, the scanner cannot recognize a command, it will respond with a NAK (15 Hex).
SOFTWARE/SERIAL NUMBER Software Number
³
9
9
9
9
Scanner Information
6
5
The scanner will transmit its software revision.
³
9
9
9
9
2
8
This barcode will transmit the “main” & “interface coprocessor” software numbers as well as the scanner’s serial number. The data is output as barcode (formatted) data (ie. 15xxx/15xxx/9876543210, where x represents any nonnumbered value).
Page 173
SECTION O
DISABLE AUXILIARY PORT * Disable AUX Port
³
4
3
7
3
0
0
AUX PORT AND SECONDARY DEVICE DATA FORMATS The following section includes features that are not available with all Metrologic scanner models. Please contact a customer service representative for additional information and technical assistance.
When using a Metrologic device as a secondary: Follow Step 1 to configure the auxiliary port to accept a Metrologic scanner as the secondary scanner. Then follow Step 2 to configure the secondary scanner to match the auxiliary port’s data format. If the secondary scanner is not a Metrologic scanner go to page 3 and follow the instructions under “When using a non-Metrologic RS-232 Device as a secondary”. The auxiliary input port’s data format must match the main output format of the secondary scanner. Step 1: Scan the following bar code to enable the auxiliary port on the primary scanner. AUX Port Data Format
³
4
3
7
3
3
0
Auxiliary Port Controls
O
1
Page 174
Auxiliary Port Controls
2
O
SECTION O AUX PORT AND SECONDARY DEVICE DATA FORMATS Step 2: Then scan the following bar codes, in order, to configure the secondary scanner. 2. Secondary Scanner Data Format
1. Enable AUX Output
³
1
2
4
8
1
7
3. Enable Comm Timeouts
³
1
1
8
4
1
2
³
4
3
7
5
3
0
0
5
4. Turn OFF Auxiliary Scanner’s Beeper (Optional)
³
3
1
8
5
Page 175
SECTION O AUX PORT AND SECONDARY DEVICE DATA FORMATS The following section includes features that are not available with all Metrologic scanner models. Please contact a customer service representative for additional information and technical assistance.
When using a non-Metrologic RS-232 device as a secondary: Scan the following bar code to enable the auxiliary port on the primary scanner. AUX Port General RS-232 Format
³
4
3
7
3
1
0
The auxiliary input port’s data format must match the main output format of the secondary device. The secondary device must be capable of RTS/CTS handshaking and have a carriage return (ASCII 0DH) terminator on the data.
The default settings for the AUX Port General RS-232 Format are: • 38400 baud • 7 data bits • 2 stop bits • Space parity
Auxiliary Port Controls
O
3
Page 176
Auxiliary Port Controls
SECTION O
O
4
ADDITIONAL AUXILIARY PORT DATA FORMATS
The auxiliary input port’s data format must match the main output format of the secondary device. Enable AUX Port with UPC Supplemental Data Format
Enable AUX Port with Code Select Data Format
³
³
4
3
7
3
4
0
4
3
7
3
5
0
Enable AUX Port with Tech 7, 8 Data Format
Enable AUX Port with Reserved 2 Data Format
³
³
4
3
7
3
6
0
4
3
7
3
8
0
Enable AUX Port with Reserved 3 Data Format
Enable AUX Port with Reserved 1 Data Format
³
³
4
3
7
3
7
0
4
3
7
3
9
0
Page 177
SECTION O
ADDITIONAL AUXILIARY PORT DATA FORMATS
Enable AUX Port with Stratos Decode Data Format
³
4
3
7
3
2
0
Auxiliary Port Controls
O
5
Page 178
Auxiliary Port Controls
SECTION O
AUXILIARY PORT BAUD RATES
AUX 115200 Baud Rate
³
4
3
7
0
1
0
AUX 38400 Baud Rate
³
4
3
7
0
8
4
3
7
0
6
AUX 57600 Baud Rate
0
³
4
3
7
0
9
0
AUX 19200 Baud Rate
0
AUX 14400 Baud Rate
³
6
O
³
4
3
7
0
7
0
AUX 9600 Baud Rate
0
³
4
3
7
0
5
0
Page 179
SECTION O
AUXILIARY PORT BAUD RATES
AUX 4800 Baud Rate
³
4
3
7
0
4
AUX 2400 Baud Rate
0
AUX 1200 Baud Rate
³
4
3
7
0
2
³
4
3
7
0
4
3
7
0
0
0
AUX 600 Baud Rate
0
³
4
3
7
0
AUX 300 Baud Rate
³
3
0
Auxiliary Port Controls
O
7
1
0
Page 180
Auxiliary Port Controls
SECTION O
8
O
AUXILIARY PORT PARITY
AUX No Parity
³
3
3
7
2
4
5
AUX Mark Parity
³
3
3
7
2
* AUX Space Parity
3
5
AUX Even Parity
³
3
3
7
2
³
3
3
7
2
1
5
2
0
5
AUX Odd Parity
2
5
³
3
3
7