Page 131

SECTION G

HARDWARE HANDSHAKING

Invert CTS Polarity (RSV2)

* Standard CTS Polarity

³

³

1

2

4

5

1

1

+12V = Inactive, do not send

1

2

4

5

0

1

-12V = Inactive, do not send +12V = Active, OK to send

-12V = Active, OK to send

Activate RTS, Do Not wait for CTS (RSV3)

* Activate RTS, Wait for CTS

³

³

1

2

4

5

1

2

1

2

4

5

0

2

Activate RTS for transmission but do not wait for CTS to send.

Wait for CTS after activating RTS.

Test CTS Not Present Before RTS (RSV4)

* Do Not Test for CTS Present Before RTS

³

1

2

4

5

1

3

³

Do not activate RTS if CTS is already present.

1

2

4

5

0

3

Activate RTS without testing if CTS is already active.

RS-232

G

7

Page 132

RS-232

SECTION G

HARDWARE HANDSHAKING

CTS Scan Transmit

³

1

2

0

4

8

G

1

* No CTS Scan Transmit

7

The CTS line is used to allow a decoded bar code to be transmitted. Use reserved code 4 to ensure 1 bar code per CTS. This will prevent the scanner from gathering data until the CTS signal has been retracted.

³

1

2

0

4

0

7

Do not support CTS scan transmit.

This feature is not available with all models. Enable DTR Support

³

1

1

5

8

1

* Disable DTR Support

7

³

1

1

5

8

0

7

The scanner will stop scanning when the Data Terminal Ready (DTR) signal goes inactive.

Enable RTS Counter Toggle

³

1

1

5

9

1

* Disable RTS Counter Toggle

5

The scanner will toggle the RTS line on a good decode.

³

1

1

5

9

0

5

Page 133

SECTION G

SOFTWARE HANDSHAKING

Enable XON/XOFF Handshaking

³

1

1

5

9

* Disable XON/XOFF Handshaking

1

4

³

1

1

5

9

0

4

The scanner will stop transmission whenever an XOFF (ASCII 13H) is received. Transmission will resume after an XON (ASCII 11H) is received.

The scanner will not test for XON/XOFF.

Enable ACK/NAK

* Disable ACK/NAK

³

1

1

5

9

1

3

³

After transmitting data, wait for an ACK (06H) or a NAK (15H) response from the host.

1

1

5

9

0

3

Do not support ACK/NAK handshaking.

If ACK is received, complete the communications cycle and look for more bar codes. If NAK is received, retransmit the last set of bar code data and wait for ACK/NAK again.

RS-232

G

9

Page 134

RS-232

SECTION G

10

G

SOFTWARE HANDSHAKING

Enable O/N Handshaking

Disable O/N Handshaking

³

³

1

1

5

9

1

2

1

1

5

9

0

2

ACK/NAK handshaking (page G 9) must be enabled for this feature to work. Support BEL/CAN in ACK/NAK

³

1

1

5

9

1

* Ignore BEL/CAN in ACK/NAK

1

³

1

1

5

9

0

1

When BEL (07H) is received, the scanner beeps 3 times and exits the communications loop. If a CAN (18H) is received, then the scanner will exit the communications loop, silently.

Ignore BEL/CAN characters in communication loop.

Enable Razz Command

Disable Razz Command

³

³

1

1

8

4

1

5

When a z is received, the scanner will RAZZ once. Multiple razzes can be sounded if the character before the z is a number and is sent within 1 second of the z. The normal BEL commands must be activated for feature.

1

1

8

4

0

Ignore z characters in communication loop.

5

Page 135

SECTION G

SOFTWARE HANDSHAKING * Disable XON/XOFF Scan Inhibit Off

Enable XON/XOFF Scan Inhibit On

³

1

1

6

0

1

1

³

1

This feature is not available with all models.

1

1

8

0

1

6

0

0

1

This feature is not available with all models.

Enable 5 Retries on ACK/NAK Time Out

³

1

* Disable 5 Retries on ACK/NAK Time Out

3

³

1

1

8

0

0

3

Allow up to 5 NAK retransmissions of the data before dropping out of the communications loop.

Do not limit retransmission to 5 NAK cycles.

Enable 5 NAK Retries

Disable 5 NAK Retries

³

1

1

5

8

1

4

³

RS-232

1

1

5

8

G

0

4

11

Page 136

RS-232

12

G

SECTION G

MISCELLANEOUS

Enable French PC Term

* Disable French PC Term

³

³

1

1

6

1

1

0

1

1

6

1

0

0

The scanner transmits PC type make/break scan codes instead of ASCII data characters. The scan codes match a WYSE French PC Terminal Emulation.

Do not transmit in French PC Term Mode.

Enable USA Wyse PC

Disable USA Wyse PC

³

1

1

6

1

1

7

³

1

1

6

1

0

7

Enables USA Wyse PC style keyboard PCTERM mode.

Disables USA Wyse PC style keyboard PCTERM mode.

* Enable Receive Data

Disable Receive Data

³

³

1

2

5

0

0

6

1

2

5

0

1

6

Disable receive port after 5 seconds.

Page 137

SECTION H

ENABLE KEYBOARD EMULATION

Load Keyboard Wedge Defaults

³

9

9

9

9

9

4

Loads default settings for keyboard wedge mode.

Enable Stand-Alone Keyboard Emulation

* Enable Keyboard Wedge Emulation

³

³

5

1

5

5

1

5

3

Use this with special standalone models that are not cabled for an external keyboard. When the StandAlone Mode is enabled, the scanner will send keyboard “power on” information and configure hardware to simulate a constant keyboard connection.

Keyboard

5

1

5

5

1

4

3

Use this with an external keyboard. Transmit in wedge mode to allow standard PC keyboards to communicate when no bar code data is available.

H

1

Page 138

Keyboard

SECTION H

4

1

6

2

2

COUNTRY/SCAN CODE TABLE SELECTS

* USA Keyboard

³

H

Switzerland Keyboard

6

0

³

4

1

6

2

8

0

Enable USA Keyboard.

Enable Swiss Keyboard

Spain Keyboard

Italy Keyboard

³

4

1

6

2

5

0

³

4

1

6

2

4

0

Enable Spanish Keyboard

Enable Italian Keyboard

Germany Keyboard

France Keyboard

³

4

1

6

2

3

0

Enable German Keyboard

³

4

1

6

2

2

0

Enable French Keyboard

Page 139

SECTION H

COUNTRY/SCAN CODE TABLE SELECTS

UK Keyboard

³

4

1

6

Belgium Keyboard

2

1

0

³

4

1

6

2

0

0

Enable UK Keyboard.

Enable Belgium Keyboard

Japanese Keyboard

IBM 4700 Financial Keyboard

³

4

1

6

2

1

0

0

³

Enable Japanese Keyboard

4

1

6

2

9

0

Enable Sweden/Finland Keyboard

Keyboard

1

6

2

7

0

Enable IBM 4700 Financial Keyboard

Sweden/Finland Keyboard

³

4

H

3

Page 140

Keyboard

SECTION H

2

1

6

4

KEYBOARD/SYSTEM TYPE

* AT Keyboard

³

H

XT Keyboard

2

1

5

³

2

1

6

2

0

5

If using an AT computer, scan the above bar code. (Includes IBM PS/2 and compatible models 50, 55, 60, 80)

If using an XT computer, scan the above bar code.

PS/2 Keyboard

Terminal KB Emulation

³

2

1

6

2

2

5

Scan the above code for PS/2 computer. (Includes IBM PC and compatible models 30, 70 and 8556)

³

2

1

6

2

3

5

Scan the above code to enable terminal keyboard emulation mode.