The text of a manual · part 4 of 5
MS9535 VoyagerBT Wireless Hand-Held Laser Scanner Installation and User's Guide, pages 31 to 40
Pages 31 to 40 of 49
The original document is the PDF (879 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic MI9535 and Metrologic MS9535
Page 31
TROUBLESHOOTING GUIDE (CONTINUED) Symptoms
Possible Causes
Solution
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The aspect ratio of the bar code is out of tolerance
Check print mode. The type of printer could be the problem. Change print settings. i.e. change to econo mode or high speed.
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The bar code may have been printed incorrectly
Check if it is a check digit/character/or border problem.
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The scanner is not configured correctly for this type of bar code
Check if check digits are set properly.
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The minimum symbol length setting does not work with the bar code
Check if the correct minimum symbol length is set.
The unit scans the bar code but there is no data
Configuration is not correct
Make sure the scanner is configured for the appropriate mode.
The unit scans but the data is not correct
Configuration is correct
Make sure that the proper PC type AT, PS2 or XT is selected. Verify correct country code and data formatting are selected. Adjust inter-character delay symptom.
Alpha characters show as lower case
Computer is in Caps Lock mode
Enable Caps Lock detect setting of the scanner to detect whether the PC is operating in Caps Lock.
27
Page 32
TROUBLESHOOTING GUIDE (CONTINUED) Symptoms
Possible Causes
Solution
The unit is transmitting each character twice
Configuration is not correct
Increase interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings.
Everything works except for a couple of characters
These characters may not be supported by that country’s key look up table
Try operating the scanner in Alt mode.
Power-up OK and scans OK but does not communicate properly to the host
Com port at the host is not working or configured properly
Check to make sure that the baud rate and parity of the scanner and the communication port match and the program is looking for “RS-232” data.
Power-up OK and scans OK but does not communicate properly to the host
Cable not connected to the proper com port
Check to make sure that the baud rate and parity of the scanner and the communication port match and the program is looking for “RS-232” data.
Power-up OK and scans OK but does not communicate properly to the host
Cable not connected to the proper com port
Check to make sure that the baud rate and parity of the scanner and the communication port match and the program is looking for “RS-232” data.
The host is receiving data but the data does not look correct
The cradle and host may not be configured for the same interface parameters
Check that the cradle and the host are configured for the same interface parameters
Characters are being dropped
Inter-character delay needs to be added to the transmitted output
Add some inter-character delay to the transmitted output
28
Page 33
DESIGN SPECIFICATIONS OPERATIONAL Light Source:
Visible Laser Diode 650 nm ± 10 nm
Laser Power:
0.96 mW (peak)
Depth of Scan Field:
0 mm – 203 mm (0” – 8”) for 0.330 mm (13 mil) bar code at default setting
Scan Speed:
72 ± 2 scan lines per second
Scan Pattern:
Single scan line
Minimum Bar Width:
0.127 mm (5.0 mil)
Decode Capability:
Autodiscriminates all standard bar codes (For others call a Metrologic service representative)
System Interfaces:
RS232/Light Pen, PC Keyboard Wedge, Stand-Alone Keyboard, USB (low speed and full speed), IBM
Print Contrast: Number of Characters Read: Roll, Pitch, Yaw: Beeper Operation: Indicators (LED) Default Settings:
35% minimum reflectance difference Up to 80 data characters (Maximum number will vary based on symbology & density) 42°, 68°, 52° 7 tones or no beep Blue = laser on, ready to scan; White = good read; Amber = battery full
MECHANICAL Length:
198 mm (7.8”)
Width:
Handle - 45 mm (1.8”), Head - 78 mm (3.1”)
Depth:
40 mm (1.6”)
Weight:
Scanner: 199 g (7.02 oz)
Cradle: 225g (7.94 oz)
ELECTRICAL Input Voltage: Power: Current: DC Transformers: Laser Class 1: EMC: Battery Capacity /Recharge Time: Radio Range:
Scanner: 5.2VDC ± 0.25V Cradle: 5.2VDC ± 0.25V Scanner: Operating = 1.15 W, Sleep = 150 mW Cradle: 0.6 W Scanner:Operating=230 mA@5VDC, Sleep=30mA@ 5VDC Cradle: 120 mA @ 5VDC Class II; 5.2V @ 2A IEC 60825-1:1993+A1:1997+A2:2001 EN 60825-1:1994+A11:1996+A2:2001 FCC, ICES-003 & EN55022 Class B 12000 scans per charge / recharge time = 2.5 hours 10 m (33 ft)
ENVIRONMENTAL Temperature: Humidity: Light Levels: Shock: Contaminants: Ventilation:
Operating = 0°C to 40° (32° to 104°F) Storage = -20°C to 50°C (-4°F to 122°F) 5% to 95% relative humidity, non-condensing Up to 4842 Lux (450 footcandles) Designed to withstand 1.5 m (5’) drops Sealed to resist airborne particulate contaminants None required
29
Page 34
DEFAULT SETTINGS Many functions of the scanner and cradle can be “programmed” – that is, enabled or disabled. The scanner and cradle are shipped from the factory programmed to a set of default conditions. The default parameter has an asterisk (*) in the charts on the following pages. If an asterisk is not in the default column then the default setting is OFF or DISABLED. Every communication does not support every parameter. If the communication supports a parameter listed in the charts on the following pages, a check mark will appear. LIGHT PEN
IBM 46XX
KBW
USB
9
9
9
9
9
Continuous Scan Mode
9
9
9
9
9
Blinky Scan
9
9
9
9
9
Continuous Blinky Scan
9
9
9
9
9
Custom (one shot) Scan
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
Short-Range Out-of-Stand
9
9
9
9
9
CodeGate Active In-Stand
9
9
9
9
9
PARAMETER Normal Scan Mode
Long-Range In-Stand
DEFAULT RS-232 *
*
Short-Range In-Stand Long-Range Out-of-Stand
*
CodeGate Inactive In-Stand
*
9
9
9
9
9
CodeGate Active Out-of Stand
*
9
9
9
9
9
9
9
9
9
9
CodeGate Inactive Out-of Stand UPC/EAN
*
9
9
9
9
9
Code 128
*
9
9
9
9
9
Code 93
*
9
9
9
9
9
Codabar
*
9
9
9
9
9
Interleaved 2 of 5 (ITF)
*
9
9
9
9
9
MOD 10 check on ITF
9
9
9
9
9
Code 11
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
Code 39 Full ASCII Code 39
30
*
Page 35
DEFAULT SETTINGS (CONTINUED) RS-232
LIGHT PEN
IBM 46XX
KBW
USB
Mod 43 Check on Code 39
9
9
9
9
9
MSI-Plessy 10/10 Check Digit
9
9
9
9
9
9
9
9
9
9
9
9
9
9
9
Variable
9
9
9
9
9
3
9
9
9
9
9
Symbol Length Lock
None
9
9
9
9
9
Bars High as Code 39
*
PARAMETER
MSI-Plessy Mod 10 Check Digit
DEFAULT
*
Paraf Support ITF ITF Symbol Lengths Minimum Symbol Length
9
9
Spaces High as Code 39
9
9
Bars High as Scanned
9
9
Spaces High as Scanned
9
9
DTS/SIEMENS DTS/NIXDORF
*
NCR F NCR S Poll light pen source
9
Beeper tone
Normal
9
9
9
9
9
Beep/transmit sequence
Before transmit
9
9
9
9
9
Communication timeout
None
9
9
9
9
9
Razzberry tone on timeout
9
9
9
9
9
Three beeps on timeout
9
9
9
9
9
Same symbol rescan timeout 250 msecs
9
9
9
9
9
Same symbol rescan timeout 375 msecs
9
9
9
9
9
Same symbol rescan timeout: 500 msecs)
9
9
9
9
9
Same symbol rescan timeout 625 msecs
9
9
9
9
9
31
Page 36
DEFAULT SETTINGS (CONTINUED) RS-232
LIGHT PEN
IBM 46XX
KBW
USB
9
9
9
9
9
9
9
9
9
9
Same symbol rescan timeout: 1000 msecs
9
9
9
9
9
No Same symbol timeout
9
9
9
9
9
Infinite Same symbol timeout
9
9
9
9
9
9
9
9
9
9
PARAMETER
DEFAULT
Same symbol rescan timeout 750 msecs Same symbol rescan timeout 875 msecs
Inter-character delay Program able in 1 msec steps (max 255 msecs)
*
1 msecs 10 msecs in KBW
Number of scan buffers (maximum)
4
9
9
9
9
9
Transmit UPC-A check digit
*
9
9
9
9
9
Transmit UPC-E check digit
9
9
9
9
9
Expand UPC-E
9
9
9
9
9
Convert UPC-A to EAN-13
9
9
9
9
9
9
9
9
9
9
Transmit lead zero on UPC-E Transmit UPC-A number system Transmit UPC-A Manufacturer ID#
*
9
9
9
9
9
*
9
9
9
9
9
Transmit UPC –A Item ID#
*
9
9
9
9
9
Transmit Codabar Start/Stop Characters
9
9
9
9
CLSI Editing (Enable)
9
9
9
9
Transmit Mod 43 Check digit on Code 39
9
9
9
9
Transit Mod 10/ITF
9
9
9
9
9
9
9
9
Scanner: Space Cradle: None
9
9
Baud Rate
9600
9
8 Data Bits
Scanner: *
9
7 Data Bits
Cradle: *
9
Stop Bits
2
9
Transmit MSI-Plessy Parity
32
Page 37
DEFAULT SETTINGS (CONTINUED) PARAMETER
DEFAULT
RS-232
LIGHT PEN
IBM 46XX
KBW
USB
Transmit Sanyo ID Characters
9
9
9
Nixdorf ID
9
9
9
LRC Enabled
9
9
9
UPC Prefix
9
9
9
UPC Suffix
9
9
9
Carriage Return
*
9
9
9
Line Feed-Disabled by default in KBW
*
9
9
9
Tab Prefix
9
9
9
Tab Suffix
9
9
9
“DE” Disable Command
9
“FL” Laser
9
Enable Command
9
DTR Handshaking support
9
RTS/CTS Handshaking
9
Character
*
9
Message RTS/CTS
9
XON/XOFF Handshaking
9
ACK/NAK
9
Two Digit Supplements
9
Five Digit Supplements
9
Bookland
9
977 (2 digit) Supplemental Requirement
9 as code 39 as code 39 as code 39 as code 39 as code 39 as code 39
9
9
9
9
9
9
9
9
9
9
Supplements are not Required
*
9
9
9
9
9
Two Digit Redundancy
*
9
9
9
9
9
9
9
9
9
9
Five digit Redundancy
33
Page 38
DEFAULT SETTINGS (CONTINUED) PARAMETER
DEFAULT
RS-232
LIGHT PEN
IBM 46XX
KBW
USB
100 msec to Find Supplement Programmable in 100 msec steps (max 800 msec)
*
9
9
9
9
9
9 as code 39
9
9 as code 39
Coupon Code 128 † Programmable Code Lengths
7 avail
9
9
9
9
9
† Code Selects with programmable Code Length Locks
3 avail
9
9
9
9
9
Programmable Prefix characters
10 avail
9
9
9
Suffix characters
10 avail
9
9
9
Prefixes for Individual Code types
9
9
9
Editing
9
9
9
Inter Scan-Code delay programmable (100 µsec steps)
9
9
800 µsec
9
Function/control Key Support Minimum Element width Programmable in 5.6 µsec steps
1 msec
9
9
RangeGate Enabled
9
9
9
9
9
Authentification
9
9
9
9
9
MTLG Challenge
9
9
9
9
9
9
9
9
9
9
Charging enabled
*
† These options are mutually exclusive. One can not be used in conjunction with the other.
34
Page 39
CRADLE AND CABLE TERMINATIONS Cradle Pinout Connections The MS9535 cradle has 3 ports on the bottom. One is for power, and the other two are for interfaces connection.The 10-pin RJ45 modular jack has diffent configurations for different interfaces. MI9535-541 RS232 / Light Pen Emulation 1
10
10-Pin RJ45
Pin 1 2 3 4 5 6 7 8 9 10
Pin 1 2 3 4 5 6 7 8 9 10
Function Ground RS-232 Transmit Output RS-232 Receive Input RTS Output CTS Input DTR Input/LTPN Source Reserved LTPN Data Reserved Shield Ground
MI9535-547 Keyboard Wedge Function Ground RS-232 Transmit Output RS-232 Receive Input PC Data PC Clock KB Clock PC +5V KB Data +5VDC Shield Ground MI9535-537 USB Pin 1 2 3 4 5 6 7 8 9 10
Function Ground RS-232 Transmit Output RS-232 Receive Input RTS Output CTS Input Reserved Reserved Reserved Reserved Shield Ground 35
Page 40
CRADLE AND CABLE TERMINATIONS (CONTINUED) USB Port Pin 1 2 3 4
Function VCC DD+ Ground
USB B Type Port
Cable Connector Configurations (Host End) RS232/Light Pen Cable [MLPN 54-54000B-N] 9
5
6
1
9-pin D-type female connector to the PC
Pin 1
Function Shield Ground
2
RS-232 Transmit Output
3
RS-232 Receive Input
4
DTR Input/Light Pen Source
5
Power/Signal Ground
6
Light Pen Data
7
CTS Input
8
RTS Output
9
+5VDC
9-Pin D-Type Connector
USB Cable [MLPN 52-52828A] Pin 1
VCC
2 3
DD+
4
Ground
36
Function USB A Type Connector