Page 21

FAILURE MODES Flashing Blue and one Razzberry Tone This indicates the scanner has experienced a laser subsystem failure. Return the unit for repair to an authorized service center.

Flashing Blue and White with Two Razzberry Tones This indicates the scanner has experienced a scanning mechanism failure. Return the unit for repair to an authorized service center.

Continuous Razzberry Tone with all LEDs off If upon power, the scanner emits a continuous razzberry tone, the scanner has experienced an electronic failure. Return the unit for repair to an authorized service center.

Three Beeps – on power up If the scanner beeps 3 times on power up then the nonvolatile memory (NovRAM) that holds the scanner configuration has failed. If the scanner does not respond after reprogramming, return the scanner for repair to an authorized service center.

Two Razzberry Tones with Steady White The scanner scans a bar code without establishing communication first. The scanner reads a bar code but the cradle fails to transmit the data.

17

Page 22

PROGRAMMING MODES The MS9535 VoyagerBT has 2 modes of programming.

¾ Bar Codes VoyagerBT can be configured by scanning the bar codes in the MetroSelect Single-Line Programming Guide (MLPN 00-02544B) and Bluetooth Programming Addendum (00-02024A). Please refer to these guides for instructions. The MetroSelect Single-Line Programming Guide can be downloaded for FREE from Metrologic’s website (www.metrologic.com).

¾ MetroSet2 This user-friendly Windows-based configuration program allows you to simply ‘point-and-click’ at the desired scanner options. This program can be downloaded for FREE from Metrologic’s website (www.metrologic.com), or set-up disks can be ordered by calling 1-800-ID-METRO.

18

Page 23

UPGRADING THE FLASH ROM FIRMWARE The Meteor program is a functional component of Metrologic’s new line of Flashbased scanners. This program allows the user of a Metrologic scanner to quickly upgrade to a new or custom version of software. It requires the use of a personal computer running under Windows 95 or greater and the use of a communication port. The user merely connects the scanner to a communications port of the PC, launches the Meteor program, and blasts off to new software upgrades. Each MS9535 and its cradle, regardless of the version number or communication protocol, can be upgraded. In other words, all RS232/Light Pen (-41), keyboard wedge (-47), USB (-07) and IBM 468X/469X (-11) units can be upgraded. To upgrade all units, an RS-232 cable (MLPN 54-54000B-N) is required. Before upgrading the flash ROM within the scanner, communication between the scanner and the cradle must be first established. The upgrades and custom software versions will be supplied by Metrologic in files called Motorola S-record files. These files contain all the information needed to upgrade the scanner. Simply add this file to the working directory or retrieve from its current location. The program guides the user with its simplistic one click approach. The user must first select the file. Once selected and verified, the file is ready to be used in the upgrade. Press the button to start the upgrading. (Contact Metrologic for additional details).

19

Page 24

LABELS Each scanner has a label on the back of the unit. This label has the model number, date of manufacture, serial number, CE and caution information. The following is an example of this label: EVITER TOUTE EXPOSITION-Lumiere laser emis par cette overture AVOID EXPOSURE –Laser light is emitted from this aperture

Patent Information-See Manual FCC and ICES-003 Information-See Manual Warranty VOID if case opened. Contains no user serviceable components. Complies with 21CFR 1040.10 & 1040.11 NACH EN60825-1:1994/A11:1996 5V

MAINTENANCE Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning. 1. 2.

20

Spray glass cleaner onto lint free, non-abrasive cleaning cloth. Gently wipe the scanner window.

Page 25

DEPTH OF FIELD

Minimum Bar Code Element Width A

B

C mm

.13

.15

- mils

5.2

5.7

-

D

E

F

G

H

J

K

-

.19

-

.25

.33

.53

-

-

7.5

-

10

13

21

-

21

Page 26 read from a scan by OCR; it may hold reading errors

IR ACTIVATION

2.5" [64 mm] Scan Width at Face

Short Range IR / / Leng Fi Range i IR f / / } /, ee

22

Distance From Face 0.0"

12.8" [320 mm]

Width of Scan Field

~ (0 mm]

40° 7.0" (102 mm 225.4 mm]

Lo 11.0" 22.0" [229 mm £51 mm}

Page 27

CONNECTING TO OTHER BLUETOOTH DEVICES Other than the cradle, the MS9535 VoyagerBT scanner can also link to other Bluetooth compatible devices, such as a computer, printer or laptop. A Bluetooth communication between the scanner and the other device must be established before the system works. ¾ When MS9535 acts as Client: The MS9535 is defaulted to act as client when connected to other Bluetooth devices. Communication is established by scanning the Bluetooth address code of the other device. a)

If the Bluetooth address is headed with FNC3 and consists of a 12-digit 3 hex value (e.g. 000CA7FFFF99), scan the address bar code to establish the communication.

³

0

0

0 C A 7

F F F F

9

9

Example Bluetooth Address With FNC3 b)

If the Bluetooth address is NOT headed with FNC3 but is just a common 12-digit hex value (e.g. 000CA7000118), scan the Get Bluetooth Address code first, and then scan the address bar code.

³

0

0

0 C A 7 F F F F F F Get Bluetooth Address

0 0 0 C A 7 0 0 0 1 1 8

Example Bluetooth Address Without FNC3

23

Page 28

CONNECTING WITH OTHER BLUETOOTH DEVICE (CONTINUED) ¾ When MS9535 acts as Server: To enable the MS9535 to act as a server and to be discovered by another Bluetooth device, scan the below Provide Service code. This will allow other Bluetooth devices to send inquiries to the scanner and attempt communication. Use this bar code to establish communication directly with a Bluetooth enabled device, bypassing the cradle.

³ 0 0 0 C A 7 0 0 0 0 0 0 Provide service to other Bluetooth devices

24

Page 29

TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Metro or 1-800-436-3876 to preserve the limited warranty terms.

Symptoms

Possible Causes

Solution

No LEDs, beep or laser -

No power is being supplied from cradle to scanner

Check transformer, outlet and power strip. Make sure the cable is plugged into the cradle properly.

Internal battery not supplying power to scanner

Place the scanner into cradle to recharge the battery.

Scanner’s white LED locks up after first scan, and razz twice

Communication is not established between scanner and cradle

Establish communication between scanner and cradle before scanning a normal bar code

Scanner scans, but white LED locks up at one scan and razz twice

The distance between scanner and cradle is beyond the 10-meter operation range

Bring the scanner back into the 10-meter communication range from the cradle.

2 Beeps with alternately flashing LEDs on Power up

Possible ROM failure

Flash ROM Upgrade Required

3 Beeps on power up

Non-volatile RAM failure

Contact a Metrologic Representative, if the unit will not hold the programmed configuration.

Continuous razz tone on power up

RAM or ROM failure

Contact a Metrologic Representative, if the unit will not function.

Razz tone and blue LED flash at power up

VLD failure

Contact a Metrologic Representative

Razz tone, blue and white LEDs flash at power up

Scanning mechanism failure

Contact a Metrologic Representative

Scanner in Cradle

No LEDs, beep, or laser Scanner out of Cradle

25

Page 30

TROUBLESHOOTING GUIDE (CONTINUED) Symptoms

Possible Causes

Solution

Unit scans, Communicates and beeps twice

Same symbol timeout set too short

Adjust same symbol timeout for a longer time.

The unit powers up, but does not scan/or beep

Beeper disabled. No tone selected

Enable beeper. Select tone.

The unit powers up, but does not scan and/or beep

Scanning a particular symbology that is not enabled

UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify that the type of bar code being read has been selected.

The unit powers up, but does not scan and/or beep

The scanner has been programmed for a character length lock, or a minimum length and bar code being scanned does not satisfy the programmed criteria

Verify that the bar code that is being scanned falls into the criteria (Typical of Non-UPC/EAN codes) The scanner defaults to a minimum of 3-character bar code.

The unit scans a bar code, but locks up after the first scan white LED stays on

The scanner is configured to support some form of host handshaking but is not receiving the signal

If the scanner is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly.

The unit scans, but the data transmitted to the host is incorrect

The scanner’s data format does not match the host system requirements

Verify that the scanner’s data format matches that required by the host. Most sure that the scanner is connected to the proper host port.

Scanner beeps at some bar codes and NOT for others of the same bar code symbology

The print quality of the bar code is suspect

Check print mode. The type of printer could be the problem. Change print settings. i.e. change to econo mode or high speed.

26