Page 31

RS-232 Demonstration Program If an RS-232 scanner is not communicating with your IBM compatible PC, key in the following BASIC program to test that the communication port and scanner are working. This program is for demonstration purposes only. It is only intended to prove that cabling is correct, the com port is working, and the scanner is working. If the bar code data displays on the screen while using this program, it only demonstrates that the hardware interface and scanner are working. At this point, investigate whether the application software and the scanner configuration match. If the application does not support RS-232 scanners, a software wedge program that will take RS-232 data and place it into a keyboard buffer may be needed. This program tells the PC to ignore RTS-CTS, Data Set Ready (DSR) and Data Carrier Detect (DCD) signals. If the demonstration program works and yours still does not, jumper RTS to CTS and Data Terminal Reading (DTR) to DCD and DSR on the back of your PC. 10 20 30 35 40 50 60 70 100 110 32766 32767

CLS ON ERROR GOTO 100 OPEN “COM1:9600,S,7,1,CS0,DS0,CD0,LF” AS #1 PRINT “SCAN A FEW BAR CODES” LINE INPUT #1, BARCODE$ PRINT BARCODE$ K$ = INKEY$: IF K$ = CHR$(27) THEN GOTO 32766 GOTO 40 PRINT “ERROR NO.”; ERR; “ PRESS ANY KEY TO TERMINATE.” K$ = INKEY$: IF K$ = “” THEN GOTO 110 CLOSE: SYSTEM END

27

Page 32

Applications and Protocols The model number on each scanner includes the scanner number and communications protocol.

Scanner Version Identifier

Communication Protocol(s)

7120 7120

41 47

7120 7120 7120

9 11 67

Full RS-232C and Light Pen Emulation Keyboard Wedge, Stand-Alone Keyboard and RS-232 Transmit/Receive OCIA and RS-232 Transmit/Receive IBM 46XX and Full RS-232C Full RS-232C

The MS7120 Hand-Held Laser Scanner with Built-in PC Keyboard Wedge Interface is designed to be used for keyboard emulation only. However, many RS-232 programmable functions that are available in other Metrologic scanners are also available as keyboard wedge functions. The most important selectable options specific to the keyboard wedge are the following:

Keyboard Type ! ** AT (includes IBM® PS2 models 50, 55, 60, 80) ! XT ! IBM PS2 (includes models 30, 70, 8556)

Keyboard Country Type ! ! ! !

** USA French Italian Belgium

! United Kingdom ! German ! Spanish ! Swiss

**Default setting. Refer to Appendix B pages 31-35 for default settings. Refer to the MetroSelect Programming Guide (MLPN 2407) for information on how to change the default settings.

28

Page 33

Appendix A Design Specifications Operational Light Source: Depth of Field: (programmable) Scan Speed: Scan Pattern: Scan Lines: Min Bar Width: Decode Capability: System Interfaces: Print Contrast: No. Characters Read:

Roll, Pitch, Yaw: Beeper Operation: Indicators (LED):

VLD 675 ± 5nm, 0.681 milliwatts (PEAK) 0 mm to 215 mm (0" to 8.5") at default 1200 scans/second 5 fields of 4 parallel lines (omnidirectional) 20 0.13 mm (5.2 mil) Autodiscriminates all standard bar codes; for other symbologies call Metrologic PC Keyboard Wedge, RS-232, OCIA, Light Pen, IBM 46xx, Stand Alone PC Keyboard 35% minimum reflectance difference up to 80 data characters (Maximum number will vary based on symbology and density) 360E, 60E, 60E 7 tones or no beep green = laser on, ready to scan red = good read, decoding

Mechanical Height: Depth: Width-Orb: Width-Base: Weight: Termination: Cable: Tilt - Orb:

150 mm (5.9") 105 mm (4.1") 80 mm (3.1") 102 mm (4.0") 380 grams (13.4 oz.) 10-pin modular RJ45 Standard 2.1 m (7') straight; optional 2.7 m (9') coiled; for other cables call Metrologic 30N vertical

29

Page 34

Appendix A (continued) Electrical Input Voltage: Power : Operating Current : DC Transformers: Laser Class: EMC:

5.2VDC ± 0.25V 1.1 W 225 mA Class II; 5.2 V @650 mA CDRH: Class IIa; EN 60 825-1: 1994/A11:1996 Class 1 FCC Class A, CISPR Class A

Environmental Operating Temperature: Storage Temperature: Humidity: Light Levels: Shock: Contaminants: Ventilation:

0EC to 40EC (32EF to 104EF) -40EC to 60EC (-40EF to 140EF) 5% to 95% relative humidity, non-condensing 4840 LUX (450 foot candles) Designed to withstand 1 m (3.1') drops Sealed to resist airborne particulate contaminants None required

Specifications subject to change without notice. This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No. 5,081,342; 5,216,232; 5,340,971; 5,525,789; 5,557,093; 5,627,359; 5,637,852

30

Page 35

Appendix B Default Settings Many functions of the scanner can be "programmed" - that is, enabled or disabled. The scanner is shipped from the factory programmed to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages. If an asterisk is not in the default column then the default setting is Off or Disabled. Every communication does not support every parameter. If the communication supports a para-meter listed in the charts on the following pages, a check mark will appear.

Parameter

Default

OCIA

RS232*

Light Pen

IBM 46XX

KBW

UPC/EAN

*

T

T

T

T

T

Code 128

*

T

T

T

T

T

Code 93

*

T

T

T

T

T

T

T

T

T

T

*

T

T

T

T

T

MOD 10 Check on ITF

T

T

T

T

T

Code 11

T

T

T

T

T

T

T

T

T

T

Codabar Interleaved 2 of 5 (ITF)

Code 39

*

Full ASCII Code 39

T

T

T

T

T

MOD 43 Check on Code 39

T

T

T

T

T

MSI-Plessey

T

T

T

T

T

MSI-Plessey 10/10 Check Digit

T

T

T

T

T

*

T

T

T

T

T

T

T

T

T

T

Variable

T

T

T

T

T

4

T

T

T

T

T

Symbol Length Lock

None

T

T

T

T

T

Bars High as Code 39

*

MSI-Plessey MOD 10 Check Digit Paraf Support ITF Symbol Lengths Minimum Symbol Length

T

Spaces High as Code 39

T

Bars High as Scanned

T

Spaces High as Scanned

T

DTS/SIEMENS

T

31

Page 36

Appendix B (continued)

Parameter

DTS/NIXDORF

Default

OCIA

*

T

NCR F

T

NCR S

T

RS232*

IBM 46XX

KBW

T

Poll Light Pen Source Beeper Tone

Normal

T

T

T

T

T

Beep/Transmit Sequence

Before Transmit

T

T

T

T

T

Communication Timeout

None

T

T

T

T

T

Razzberry Tone on Timeout

T

T

T

T

T

Three Beeps on Timeout

T

T

T

T

T

No Beeps on Timeout

*

T

T

T

T

T

Enter Power Save Mode

10 mins.

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

Same Symbol Rescan Timeout: 1250 msecs

T

T

T

T

T

Same Symbol Rescan Timeout: 2000 msecs

T

T

T

T

T

1 msecs 10msecs in KBW

T

T

T

T

Number of Scan Buffers

1

T

T

T

T

T

Transmit UPC-A Check Digit

*

T

T

T

T

T

Transmit UPC-E Check Digit

T

T

T

T

T

Expand UPC-E

T

T

T

T

T

Convert UPC-A to EAN-13

T

T

T

T

Transmit Lead Zero on UPC-E

T

T

T

T

Convert EAN-8 to EAN-13

T

T

T

T

Same Symbol Rescan Timeout: 200 msecs Same Symbol Rescan Timeout: 500 msecsProgrammable in 50 msec steps(MAX 6.35 seconds)

Intercharacter Delay Programm able in 1 msec steps (MAX 255 msecs)

32

Light Pen

*

T

Transmit UPC-A Number System

*

T

T

T

T

T

Transmit UPC-A Manufacturer ID#

*

T

T

T

T

T

Page 37

Appendix B (continued)

Parameter

Default

OCIA

RS232*

Light Pen

IBM 46XX

KBW

*

T

T

T

T

T

Transmit Codabar Start/Stop Characters

T

T

T

T

CLSI Editing (Enable)

T

T

T

T

Transmit Mod 43 Check Digit on Code 39

T

T

T

T

Transmit Code 39 Stop/Start Characters

T

T

T

T

Transmit Mod 10/ITF

T

T

T

T

Transmit MSI-Plessey Check Characters

T

T

T

T

Transmit UPC-A Item ID#

Parity

Space

T

Baud Rate

9600

T T

8 Data Bits 7 Data Bits

*

T

Transmit Sanyo ID Characters

T

T

Nixdorf ID

T

T

LRC Enabled

T

T

UPC Prefix

T

T

UPC Suffix

T

T

Transmit AIM ID Characters

T

T

STX Prefix

T

T

ETX Suffix

T

T

Carriage Return

*

T

T

Line Feed - disabled by default in KBW

*

T

T

Tab Prefix

T

T

Tab Suffix

T

T

"DE" Disable Command

T

"FL" Laser Enable Command

T

DTR Handshaking Support

T

RTS/CTS Handshaking

T

33

Page 38

Appendix B (continued)

Parameter

Character RTS/CTS

Default

OCIA

RS232*

Light Pen

IBM 46XX

KBW

T

*

Message RTS/CTS

T

XON/XOFF Handshaking

T

ACK/NAK

T

Two Digit Supplements

T

T as code 39

T

T

Five Digit Supplements

T

T as code 39

T

T

Bookland

T

T as code 39

T

T

977 (2 digit) Supplemental Requirement

T

T

T

T

T

Supplements are not Required

*

T

T

T

T

T

Two Digit Redundancy

*

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T as code 39

T

T

T

T

T

T

T

T

T

T

Five Digit Redundancy 100 msec to Find Supplement Programmable in 100msec steps (MAX 800 msec)

*

Coupon Code 128

Programmable Code Lengths

7 aval.

Programmable Prefix Characters

10 avail.

T

T

Suffix Characters Prefixes for individual Code Types T

Editing Inter Scan-Code Delay Program mable (100 msec steps)

T

T

800 msec

Function/Control Key Support Minimum Element WidthProgrammable in 5.6 F sec steps

T

1 msec

Depth of Field Variable Depth of Field

34

*

T

T

T

T

T

Page 39

Appendix B (continued)

Parameter

Default

OCIA

RS232*

Light Pen

IBM 46XX

KBW

*

T

T

T

T

T

Extended Depth of Field

T

T

T

T

T

Long Depth of Field

T

T

T

T

T

Ultra Close Depth of Field

T

T

T

T

T

Normal Depth of Field

35

Page 40

Appendix C Pin Assignments Pin Assignments for the PowerLink Cable The MS7120 scanner interfaces terminate to a 10-pin modular jack. Connect the 10-pin modular plug of the PowerLink cable into the jack then connect the other end of the PowerLink cable to the host. (Refer to page 6 for details). Due to the variations in current supplied by the many available PC’s, Metrologic suggests the use of an external power supply. “9" OCIA

“11" IBM 46XX/RS-232*

PIN FUNCTION

PIN FUNCTION

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

Ground RS-232 Transmit Output RS-232 Receive Input RDATA RDATA Return Clock in Clock out Clock in Return/Clock out Rtrn +5VDC Shield Ground

Ground RS-232 Transmit Output RS-232 Receive Input RTS Output CTS Input DTR Input IBM 46XX Transmit IBM 46XX Receive +5VDC Shield Ground

“67" RS-232/LTPN*

“41" RS-232/LTPN

PIN FUNCTION

PIN FUNCTION

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

Ground RS-232 Transmit Output RS-232 Receive Input RTS Output CTS Input DTR Input/LTPN Source Reserved LTPN Data +5VDC Shield Ground

*Preliminary Options listed are program/cable selections

36

Ground RS-232 Transmit Output RS-232 Receive Input RTS Output CTS Input DTR Input/LTPN Source Reserved LTPN Data +5VDC Shield Ground