Page 21
Depth of Field by Minimum Bar Code Element Width (continued) Optimal High Density Depth of Field (default)
17
Page 22
Depth of Field by Minimum Bar Code Element Width (continued) Close Depth of Field
18
Page 23
Depth of Field by Minimum Bar Code Element Width (continued) Normal Depth of Field
19
Page 24
Depth of Field by Minimum Bar Code Element Width (continued) Far Depth of Field
20
Page 25
Maintenance Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning. 1. Spray glass cleaner onto lint free, non-abrasive cleaning cloth. 2. Gently wipe the scanner window.
21
Page 26
Troubleshooting Guide The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms on page 39. All Interfaces
MS7120 Series Troubleshooting Guide SYMPTOMS
POSSIBLE CAUSE(S)
SOLUTION
No LEDs, beep or motor spin
No power is being supplied to the scanner
Check transformer, outlet and power strip. Make sure the cable is plugged into the scanner
No LEDs, beep
No power is being supplied to the scanner from host
Some host system’s cannot supply enough current to power Orbit. Use the power supply included with the scanner.
3 beeps on power up
Non-volatile RAM failure
Contact a Metrologic Representative, if the unit will not hold the programmed configuration
Continuous razz tone on power up
RAM or ROM failure
Contact a Metrologic Representative, if the unit will not function
Razz tone and green LED flash at power up
VLD failure
Contact a Metrologic Representative
Razz tone and both LEDs flash at power up
Scanner motor failure
Contact a Metrologic Representative
Unit scans, Communicates and beeps twice
Same symbol timeout set too short
Adjust same symbol timeout for a longer time
22
Page 27
Troubleshooting Guide (continued) SYMPTOMS
POSSIBLE CAUSE(S)
SOLUTION
The unit powers up, but does not scan and/or beep
Beeper disabled. No tone selected
Enable beeper. Select tone
The unit powers up, but does not scan and/or beep
Scanning a particular symbology that is not enabled
UPC/EAN, Code 39, interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify that the type of bar code being read has been selected
The unit powers up, but does not scan and/or beep
The scanner has been programmed for a character length lock, or a minimum length and bar code being scanned does not satisfy the programmed criteria
Verify that the bar code that is being scanned falls into the criteria. (Typical of Non-UPC/EAN codes.) (The scanner defaults to a minimum of 4 character bar code)
The unit scans a bar code, but locks up after the first scan (red LED stays on)
The scanner is configured to support some form of host handshaking but is not receiving the signal
If the scanner is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly
The unit scans, but the data transmitted to the host is incorrect
The scanner’s data format does not match the host system requirements
Verify that the scanner’s data format matches that required by the host. Make sure that the scanner is connected to the proper host port
23
Page 28
Troubleshooting Guide (continued) SYMPTOMS
POSSIBLE CAUSE(S)
SOLUTION
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The print quality of the bar code is suspect
Check print mode. The type of printer could be the problem. Change print settings. For example change to econo mode or high speed
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The aspect ratio of the bar code is out of tolerance
Check print mode. The type of printer could be the problem. Change print settings. ie change to econo mode or high speed
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The bar code may have been printed incorrectly
Check if it is a check digit/character/or border problem
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The scanner is not configured correctly for this type of bar code
Check if check digits are set properly
Scanner beeps at some bar codes and NOT for others of the same bar code symbology
The minimum symbol length setting does not work with the bar code
Check if the correct minimum symbol length is set
24
Page 29
Troubleshooting Guide (continued) Keyboard Wedge Only SYMPTOMS
POSSIBLE CAUSE(S)
SOLUTION
The unit scans the bar code but there is no data
Configuration is not correct
Make sure the scanner is configured for the appropriate mode. Check internal jumper
The unit scans but the data is not correct
Configuration is not correct
Make sure that the proper PC type AT, PS2 or XT is selected. Verify correct country code and data formatting are selected. Adjust intercharacter delay SYMPTOM
The unit is transmitting each character
Configuration is not correct
Increase the interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings.
Alpha characters show as lower case
Computer is in Caps Lock mode
Enable Caps Lock detect setting of the scanner to detect whether the PC is operating in Caps Lock
Everything works except for a couple of characters
These characters may not be supported by that country’s key look up table
Try operating the scanner in Alt mode
25
Page 30
Troubleshooting Guide (continued) RS-232 only SYMPTOMS
POSSIBLE CAUSE(S)
SOLUTION
Power-up OK and scans OK but does not communicate properly to the host
Com port at the host is not working or configured properly
Check to make sure that the baud rate and parity of the scanner and the communication port match and the program is looking for “RS-232" data
Power-up OK and scans OK but does not communicate properly to the host
Cable not connected to the proper com port
Check to make sure that the baud rate and parity of the scanner and the communication port match and the program is looking for “RS-232" data
Power-up OK and scans OK but does not communicate properly to the host
Com port not operating properly
Check to make sure that the baud rate and parity of the scanner and the communication port match and the program is looking for “RS-232" data
The host is receiving data but the data does not look correct
The scanner and host may not be configured for the same interface font
Check that the scanner and the host are configured for the same interface font
Characters are being dropped
Intercharacter delay needs to be added to the transmitted output
Add some intercharacter delay to the transmitted output by using the MetroSelect Programming Guide MLPN 2407
26