Page 127

SECTION G

SOFTWARE HANDSHAKING

Enable XON/XOFF Handshaking

³

1

1

5

9

* Disable XON/XOFF Handshaking

1

4

³

1

1

5

9

0

4

The scanner will stop transmission whenever an XOFF (ASCII 13H) is received. Transmission will resume after an XON (ASCII 11H) is received.

The scanner will not test for XON/XOFF.

Enable ACK/NAK

* Disable ACK/NAK

³

1

1

5

9

1

3

³

After transmitting data, wait for an ACK (06H) or a NAK (15H) response from the host.

1

1

5

9

0

3

Do not support ACK/NAK handshaking.

If ACK is received, complete the communications cycle and look for more bar codes. If NAK is received, retransmit the last set of bar code data and wait for ACK/NAK again.

RS-232

G

9

Page 128

RS-232

G

10

SECTION G

SOFTWARE HANDSHAKING

Support BEL/CAN in ACK/NAK

* Ignore BEL/CAN in ACK/NAK

³

1

1

5

9

1

1

³

1

1

5

9

0

1

When BEL (07H) is received, the scanner beeps 3 times and exits the communications loop. If a CAN (18H) is received, then the scanner will exit the communications loop, silently.

Ignore BEL/CAN characters in communication loop.

Enable Razz Command

Disable Razz Command

³

³

1

1

8

4

1

5

When a z is received, the scanner will RAZZ once. Multiple razzes can be sounded if the character before the z is a number and is sent within 1 second of the z. The normal BEL commands must be activated for feature.

1

1

8

4

0

Ignore z characters in communication loop.

5

Page 129

SECTION G

SOFTWARE HANDSHAKING

Enable 5 Retries on ACK/NAK Time Out

³

1

1

8

0

1

* Disable 5 Retries on ACK/NAK Time Out

3

³

Allow up to 5 NAK retransmissions of the data before dropping out of the communications loop.

1

1

8

0

0

3

Do not limit retransmission to 5 NAK cycles.

RS-232

G

11

Page 130

RS-232

G

12

SECTION G

MISCELLANEOUS

Enable French PC Term

* Disable French PC Term

³

³

1

1

6

1

1

0

1

1

6

1

0

0

The scanner transmits PC type make/break scan codes instead of ASCII data characters. The scan codes match a WYSE French PC Terminal Emulation.

Do not transmit in French PC Term Mode.

Enable USA Wyse PC

Disable USA Wyse PC

³

1

1

6

1

1

7

Enables USA Wyse PC style keyboard PCTERM mode.

³

1

1

6

1

0

7

Disables USA Wyse PC style keyboard PCTERM mode.

Page 131

SECTION H

ENABLE KEYBOARD EMULATION

Load Keyboard Wedge Defaults

³

9

9

9

9

9

4

Loads default settings for keyboard wedge mode.

Enable Stand-Alone Keyboard Emulation

* Enable Keyboard Wedge Emulation

³

³

5

1

5

5

1

5

3

Use this with special standalone models that are not cabled for an external keyboard. When the StandAlone Mode is enabled, the scanner will send keyboard “power on” information and configure hardware to simulate a constant keyboard connection.

5

1

5

5

1

4

3

Use this with an external keyboard. Transmit in wedge mode to allow standard PC keyboards to communicate when no bar code data is available.

Keyboard

H

1

Page 132

Keyboard

SECTION H

4

1

6

2

2

COUNTRY/SCAN CODE TABLE SELECTS

* USA Keyboard

³

H

Switzerland Keyboard

6

0

³

4

1

6

2

8

0

Enable USA Keyboard.

Enable Swiss Keyboard

Spain Keyboard

Italy Keyboard

³

4

1

6

2

5

0

³

4

1

6

2

4

0

Enable Spanish Keyboard

Enable Italian Keyboard

Germany Keyboard

France Keyboard

³

4

1

6

2

3

0

Enable German Keyboard

³

4

1

6

2

2

0

Enable French Keyboard

Page 133

SECTION H

COUNTRY/SCAN CODE TABLE SELECTS

UK Keyboard

³

4

1

6

Belgium Keyboard

2

1

0

³

4

1

6

2

0

0

Enable UK Keyboard.

Enable Belgium Keyboard

Japanese Keyboard

IBM 4700 Financial Keyboard

³

4

1

6

2

1

0

0

³

Enable Japanese Keyboard

4

1

6

2

9

1

6

2

7

0

Enable IBM 4700 Financial Keyboard

Sweden/Finland Keyboard

³

4

0

Enable Sweden/Finland Keyboard

Keyboard

H

3

Page 134

Keyboard

SECTION H

2

1

6

4

KEYBOARD/SYSTEM TYPE

* AT Keyboard

³

H

XT Keyboard

2

1

5

³

2

1

6

2

0

5

If using an AT computer, scan the above bar code. (Includes IBM PS/2 and compatible models 50, 55, 60, 80)

If using an XT computer, scan the above bar code.

PS/2 Keyboard

Terminal KB Emulation

³

2

1

6

2

2

5

Scan the above code for PS/2 computer. (Includes IBM PC and compatible models 30, 70 and 8556)

³

2

1

6

2

3

5

Scan the above code to enable terminal keyboard emulation mode.

Page 135

SECTION H

SPECIAL KEYBOARD FEATURES

Transmit Make Code Only

³

1

1

6

3

* Transmit Make/Break Code

1

1

³

Do not scan unless instructed by a Metrologic representative.

1

1

6

3

1

6

3

0

1

Do not scan unless instructed by a Metrologic representative.

Do Not Transmit F0H Break Code

³

1

* Transmit F0H Break Code

0

0

³

1

1

6

3

1

0

The scanner will not transmit the F0H in the break-code sequence.

The scanner will transmit the F0H in the break-code sequence.

Transmit Cleanup Bit

* Do Not Transmit Cleanup Bit

³

1

1

6

3

1

5

³

Use for certain NEC computers.

Keyboard

H

5

1

1

6

3

0

5

Page 136

Keyboard

SECTION H

1

1

6

2

6

SPECIAL KEYBOARD FEATURES

Enable Alt Mode

³

H

* Disable Alt Mode

1

7

³

The scanner will duplicate the following keyboard sequence: Hold down ALT key and Type decimal number that corresponds to the appropriate character.

1

1

6

2

0

Caution: If the host software application uses the right ALT key as a “Hot” key, ALT mode must be disabled.

Enable Auto Detect Mode (AT/PS2)

* Disable Auto Detect Mode (AT/PS2)

³

³

1

1

6

2

1

4

Automatically detects caps lock status.

7

1

1

6

2

0

4

The Auto Detect Caps Lock feature is not supported.