Page 117

SECTION F

PLESSEY

* No MSI Plessey Check Digit

³

2

0

0

7

0

4

The scanner will not test MSI Plessey bar codes for a check digit.

Enable MSI Plessey MOD 10/10 Check Digit

* Enable MSI Plessey MOD 10 Check Digit

³

³

2

0

0

7

3

4

2

0

0

7

2

4

The scanner will test MSI Plessey bar codes for a double Modulo 10 check digit.

The scanner will test MSI Plessey bar codes for a single Modulo 10 check digit.

Transmit MSI Plessey Check Digit

* Do Not Transmit MSI Plessey Check Digit

³

³

1

0

7

7

1

1

This option works in conjunction with one or both of the Enabled MSI Plessey Mode options.

Code Formatting

1

0

7

7

0

1

The scanner will not transmit MSI Plessey’s check digit characters.

F

9

Page 118

Code Formatting

F

10

SECTION F

2 OF 5

Enable Mod 10 Check on ITF

³

1

0

0

* Disable MOD 10 Check on ITF

3

1

0

³

1

0

0

3

0

0

The scanner will only scan Interleaved 2 of 5 (ITF) bar codes that have a Modulo 10 check digit.

The scanner will not test Interleaved 2 of 5 (ITF) bar codes for a Modulo 10 check digit.

Transmit Mod 10 Check Digit on ITF

* Do Not Transmit Mod 10 Check Digit on ITF

³

1

0

7

7

1

4

³

1

0

7

7

0

4

The scanner transmits Interleaved 2 of 5 (ITF) Mod 10 check character.

The scanner will not transmit Interleaved 2 of 5 (ITF) Mod 10 check digit character. This feature works in conjunction with Mod 10 check on ITF. Both must be enabled for this feature to work.

Transmit Matrix 2 of 5 Check Digit

* Do Not Transmit Matrix 2 of 5 Check Digit.

³

1

0

7

8

1

2

³

1

0

7

8

0

2

Page 119

SECTION G

ENABLE RS-232 MODE

* Enable RS-232 Mode

³

4

1

5

5

5

4

When enabled the scanner will work with RS-232 ±12V serial output.

RS-232

G

1

Page 120

RS-232

G

SECTION G

2

PARITY FEATURES

A parity bit is an extra data bit used to help catch data transmission errors. The scanner’s parity must match the host’s parity.

No Parity

³

Odd Parity

³

3

1

3

1

6

0

4

5

0

1

5

* Space Parity

6

0

0

5

³

3

1

6

Select Odd Parity to set the parity bit to either 1 or 0 to ensure an odd number of bits are 1’s.

Select to set the parity bit always 0.

Even Parity

Mark Parity

³

3

1

6

0

2

5

Select to set the parity bit to either 1 or 0 to ensure an even number of bits are 1’s.

³

3

1

6

0

3

5

Select to set the parity bit always 1.

Page 121

SECTION G

BAUD RATES

A “Baud” or “Baud Rate” is the speed at which data is transmitted. Select a Baud for the scanner that matches the host device.

115200 BAUD Rate

³

57600 BAUD Rate

³

4

1

5

8

4

1

5

8

1

5

8

1

0

8

0

6

0

38400 BAUD Rate

9

0

³

19200 BAUD Rate

³

4

4

1

5

8

14400 BAUD Rate

7

0

³

RS-232

G

3

4

1

5

8

0

Page 122

RS-232

G

4

SECTION G

BAUD RATES

* 9600 BAUD Rate

³

4

1

5

8

5

4800 BAUD Rate

0

2400 BAUD Rate

³

4

1

5

8

4

1

5

8

4

1

5

8

4

0

2

0

0

0

1200 BAUD Rate

3

0

600 BAUD Rate

³

³

³

4

1

5

8

300 BAUD Rate

1

0

³

4

1

5

8

Page 123

SECTION G

DATA/STOP BITS

* 7 Data Bits

³

1

1

6

8 Data Bits

0

0

3

³

1

1

6

0

1

3

0

0

4

Number of data bits transmitted for each character.

1 Stop Bit

³

1

1

* 2 Stop Bits

6

0

1

4

³

RS-232

G

5

1

1

6

Page 124

RS-232

SECTION G

1

1

5

8

6

HARDWARE HANDSHAKING

Enable RTS/CTS Handshaking

³

G

* Disable RTS/CTS Handshaking

1

6

³

1

1

5

8

0

Output a Request to Send (RTS) signal and wait for a Clear To Send (CTS) signal before transmitting data.

Do not use RTS/CTS handshaking.

* Character RTS/CTS

Message RTS/CTS

³

1

1

5

8

1

5

³

1

1

5

8

0

6

5

Activate/Deactivate RTS signal for each character.

Activate RTS before sending the first character and leave it active until after the last character has been transmitted.

Invert RTS Polarity (RSV1)

* Standard RTS Polarity

³

³

1

2

4

+12V = Inactive -12V = Active

5

1

0

1

2

4

5

0

0

Use standard RTS polarity -12V = Inactive +12V = Active

Page 125

SECTION G

HARDWARE HANDSHAKING

Invert CTS Polarity (RSV2)

* Standard CTS Polarity

³

³

1

2

4

5

1

1

+12V = Inactive, do not send

1

2

4

5

0

1

-12V = Inactive, do not send +12V = Active, OK to send

-12V = Active, OK to send

Activate RTS, Do Not wait for CTS (RSV3)

* Activate RTS, Wait for CTS

³

³

1

2

4

5

1

2

1

2

4

5

0

2

Activate RTS for transmission but do not wait for CTS to send.

Wait for CTS after activating RTS.

Test CTS Not Present Before RTS (RSV4)

* Do Not Test for CTS Present Before RTS

³

1

2

4

5

1

3

³

Do not activate RTS if CTS is already present.

1

2

4

5

0

3

Activate RTS without testing if CTS is already active.

RS-232

G

7

Page 126

RS-232

SECTION G

1

1

5

8

8

HARDWARE HANDSHAKING

Enable DTR Support

³

G

1

* Disable DTR Support

7

³

1

1

5

8

0

7

The scanner will stop scanning when the Data Terminal Ready (DTR) signal goes inactive.

Enable RTS Counter Toggle

³

1

1

5

9

1

* Disable RTS Counter Toggle

5

The scanner will toggle the RTS line on a good decode.

³

1

1

5

9

0

5