Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 5 of 6

MS6720 Hand-Held Laser Scanner Installation and User's Guide, pages 37 to 45

Pages 37 to 45 of 52

The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Metrologic MS6720

Page 37

APPENDIX B Default Settings Many functions of the scanner can be "programmed" - that is, enabled or disabled. The scanner is shipped from the factory programmed to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages. If an asterisk is not in the default column then the default setting is Off or Disabled. Every communication does not support every parameter. If the communication supports a parameter listed in the charts on the following pages, a check mark will appear. Parameter

Default

OCIA

RS-232*

Light Pen

IBM 46XX

KBW

UPC/EAN

*

✓

✓

✓

✓

✓

Code 128

*

✓

✓

✓

✓

✓

Code 93

*

✓

✓

✓

✓

✓

Codabar

*

✓

✓

✓

✓

✓

Interleaved 2 of 5 (ITF)

*

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

MOD 10 Check on ITF Code 11 *

✓

✓

✓

✓

✓

Full ASCII Code 39

✓

✓

✓

✓

✓

MOD 43 Check on Code 39

✓

✓

✓

✓

✓

Code 39

MSI-Plessey

✓

✓

✓

✓

✓

MSI-Plessey 10/10 Check Digit

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

MECCA

✓

✓

✓

✓

✓

Paraf Support

✓

✓

✓

✓

✓

MSI-Plessey MOD 10 Check Digit

*

Variable

✓

✓

✓

✓

✓

Minimum Symbol Length

04

✓

✓

✓

✓

✓

Symbol Length Lock

None

✓

✓

✓

✓

✓

ITF Symbol Lengths

Bars High as Code 39

*

✓

Spaces High as Code 39

✓

Bars High as Scanned

✓

Spaces High as Scanned

✓

DTS/SIEMENS

✓

31

Page 38

APPENDIX B (CONTINUED) Parameter

Default

OCIA

RS-232*

Light Pen

IBM 46XX

KBW

* DTS/NIXDORF

✓

NCR F

✓

NCR S

✓ ✓

Poll Light Pen Source Normal

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

Communication Timeout

✓

✓

✓

✓

✓

Razzberry Tone on Timeout

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

Transmit UPC-A Check Digit

✓

Transmit UPC-E Check Digit Expand UPC-E Convert UPC-A to EAN-13 Transmit Lead Zero on UPC-E

Beeper Tone Beep/Transmit Sequence

Before Transmit None

Three Beeps on Timeout * No Beeps on Timeout IR Timeout

10 Min.

Same Symbol Rescan Timeout: 200 msecs Same Symbol Rescan Timeout: 500 msecs

*

Same Symbol Rescan Timeout: 1250 msecs Same Symbol Rescan Timeout: 2000 msecs 1 msecs

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

Transmit Codabar Start/Stop Characters

✓

✓

✓

✓

CLSI Editing (Enable)

✓

✓

✓

✓

Transmit Mod 43 Check Digit on Code 39

✓

✓

✓

✓

Transmit Code 39 Stop/Start Characters

✓

✓

✓

✓

Intercharacter Delay Scan Buffer 1 of 2

1 *

Convert EAN-8 to EAN-13 Transmit UPC-A Number System

32

*

✓

✓

Page 39

APPENDIX B (CONTINUED) Default

Parameter Transmit MSI-Plessey Characters

Check

Parity

Space

Baud Rate

9600

KBW

✓

✓

✓

✓

✓

✓

RS-232*

✓ ✓

Light Pen

✓ ✓

8 Data Bits 7 Data Bits

IBM 46XX

OCIA

✓

*

Transmit Sanyo ID Characters

✓

✓

Nixdorf ID

✓

✓

Shell Schulmberger Formatting

✓

✓

UPC Prefix

✓

✓

UPC Suffix

✓

✓

Transmit AIM ID Characters

✓

✓

STX Prefix

✓

✓

ETX Suffix

✓

✓

Carriage Return

*

✓

✓

Line Feed

*

✓

✓

Tab Prefix

✓

✓

Tab Suffix

✓

✓

"DE" Disable Command

✓

"FL" Laser Enable Command

✓

DTR Handshaking Support

✓

RTS/CTS Handshaking

✓

Character RTS/CTS

✓

*

Message RTS/CTS

✓

XON/XOFF Handshaking

✓

ACK/NAK

✓

Two Digit Supplements

✓

✓ as code 39

✓

✓

Five Digit Supplements

✓

✓ as code 39

✓

✓

Bookland

✓

✓ as code 39

✓

✓

33

Page 40

APPENDIX B (CONTINUED) Parameter

Default

977 (2 digit) Supplemental Requirement

OCIA

RS-232*

Light Pen

IBM 46XX

KBW

✓

✓

✓

✓

✓

Supplements are not Required

*

✓

✓

✓

✓

✓

Two Digit Redundancy

*

✓

✓

✓

✓

✓

Five Digit Redundancy

✓

✓

✓

✓

✓

200 msec to Find Supplement

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓

✓ as code 39

✓

✓

100 msec to Find Supplement

Coupon Code 128

34

*

Page 41

APPENDIX C Pin Assignments for the Coil Cable The MS6720 scanners are terminated to a 10 position shielded modular connector. All coil cables (MLPN 44-44780) for the MS6720 scanner are terminated the same. The difference between versions is the end of the cable going into the scanner. This connector plugs into different “J” positions on various computer/interface boards. Since each computer/interface board is different, the output signals are different.

Version “9” (OCIA)

Version “11” (46XX)

Pin 1 2 3 4 5 6 7 8 9 10

Pin 1 2 3 4 5 6 7 8 9 10

Function Power/Signal Ground RDATA RDATA Return Clock In Clock In Return Clock Out Clock Out Return No Connection +5 VDC Power to Scanner OCIA Shield Ground

Function Power/Signal Ground RS-232 Transmit Output RS-232 Receive Input RTS Output CTS Input IBM 46XX Transmit IBM 46XX Receive No Connection +5 VDC Power to Scanner Shield Ground

Version “14” (232)

Version “15” (LTPN)

PinFunction 1 Power/Signal Ground 2 RS-232 Transmit Output 3 RS-232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input 7 DSR Output 8 No Connection 9 +5 VDC Power to Scanner 10 Shield Ground

Pin 1 2 3 4 5 6 7 8 9 10

Function Power/Signal Ground RS-232 Transmit Output RS-232 Receive Input RTS Output CTS Input Light Pen Source +5V Light Pen Data No Connection +5 VDC Power to Scanner Shield Ground

35

Page 42

APPENDIX C (CONTINUED) Pin Assignments for the MCA951 There is a 9-pin female D-type connector, located on the MCA, used to connect the MCA to the host device. The output signals on the 9-pin host end of the MCA are dependent upon which version of the scanner that is being used. The following is a list of the pin assignments for the different versions: Version “9” (OCIA)*** Pin Function

Version “11” (46XX) Pin Function

1** 2 3 4 5 6 7 8 9*

1** 2 3 4 5 6 7 8 9*

OCIA Shield Ground RDATA RDATA Return Clock Out Power/Signal Ground Clock Out Return Clock In Return Clock In +5VDC Power to Scanner

Shield Ground RS-232 Transmit Output RS-232 Receiver Input IBM 4680 -B Power/Signal Ground IBM 4680 +A Clear to Send Input Request to Send Output +5VDC Power to Scanner

Version “14” (232)

Version “15” (LTPN)

Pin

Function

Pin

1** 2 3 4 5 6 7 8 9*

Shield Ground RS-232 Transmit Output RS-232 Receiver Input Data Terminal Ready Input Power/Signal Ground Data Set Ready Output Clear to Send Input Request to Send Output +5VDC Power to Scanner

1** 2 3 4 5 6 7 8 9*

Function Shield Ground RS-232 Transmit Output RS-232 Receive Input Light Pen Source (+5V Input) Power/Signal Ground Light Pen Data (Output) Clear to Send (Input) Request to Send (Output) +5VDC Power to Scanner

*When the host supplies power to the scanner, this is the pin assignment for the +5VDC for the scanner. If, in the application, the host device will supply the power necessary for the scanner, reposition an internal jumper within the MCA and plug the 4 position ground jumper to the power supply connector for FCC and ESD purposes. (Refer to MS6720 Installation: Powered by External Power Supply page 5) **Pin 1 of the MCA provides a connection point for various ground/shield ground configurations on different Metrologic products. Internal jumper JP2 of the MCA gives end users the option of changing pin 1 of the DB9 into a no connect (NC). Simply remove the jumper from the pins, then pin 1 of the DB9 becomes an open/no connect pin. ***JP2 should ALWAYS be in place for OCIA applications

36

Page 43

APPENDIX C (CONTINUED) Pin Assignments for the 5-pin DIN and 6-pin mini-DIN MS6720 HandHeld Laser Scanner with Built-in PC Keyboard Wedge Interface

The coil cable is terminated with a 5-pin DIN female connector on one end, and a 6-pin mini DIN male on the other. Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other. Coil Cable 4 1

2

Adapter Cable Connectors 2

5

21 4 3 6 5

12 3 4 5 6

6-pin Male

6-pin Female

3

5-pin Female

5 3

4 1

5-pin Male

According to the termination required, connect the appropriate end of the adapter cable to the coil cable, leaving the necessary termination exposed for connecting to the keyboard and the keyboard port on the PC. The pin assignments are as follows: 5-pin Female DIN

6-pin Female mini-DIN

Pin

Function

Pin

Function

1 2 3 4 5

Keyboard Clock Keyboard Data No Connect Power Ground +5 Volts DC

1 2 3 4 5 6

Keyboard Data No Connect Power Ground +5 Volts DC Keyboard Clock No Connect

5-pin Male DIN

6-pin Male mini-DIN

Pin

Function

Pin

Function

1 2 3 4 5

PC Clock PC Data No Connect Power Ground +5 Volts DC

1 2 3 4 5 6

PC Data No Connect Power Ground +5 Volts DC PC Clock No Connect

37

Page 44

APPENDIX D Limited Warranty The MS6720 scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS6720 scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS6720 scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S. Federal, state and local laws, regulations and ordinances pertaining to their production and labeling. This warranty is limited to repair, replacement of Product or refund of Product price at the sole discretion of Metrologic. Faulty equipment must be returned to the Metrologic facility in Blackwood, New Jersey, U.S.A. or Puchheim, Germany. To do this, contact Metrologic’s Customer Service/Repair Department to obtain a Returned Material Authorization (RMA) number. In the event that it is determined the equipment failure is covered under this warranty, Metrologic shall, at its sole option, repair the Product or replace the Product with a functionally equivalent unit and return such repaired or replaced Product without charge for service or return freight, whether distributor, dealer/reseller, or retail consumer, or refund an amount equal to the original purchase price. This limited warranty does not extend to any Product which, in the sole judgement of Metrologic, has been subjected to abuse, misuse, neglect, improper installation, or accident, nor any damage due to use or misuse produced from integration of the Product into any mechanical, electrical or computer system. The warranty is void if the case of Product is opened by anyone other than Metrologic’s repair department or authorized repair centers. THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES, EITHER EXPRESS OR IMPLIED, AND SPECIFICALLY EXCLUDES, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE UNDER THE UNIFORM COMMERCIAL CODE, OR ARISING OUT OF CUSTOM OR CONDUCT. THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE EXCLUSIVE AND IN LIEU OF ANY OTHER RIGHTS OR REMEDIES. IN NO EVENT SHALL METROLOGIC BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES, INCIDENTAL DAMAGES, DAMAGES TO PERSON OR PROPERTY, OR EFFECT ON BUSINESS OR PROPERTY, OR OTHER DAMAGES OR EXPENSES DUE DIRECTLY OR INDIRECTLY TO THE PRODUCT, EXCEPT AS STATED IN THIS WARRANTY. IN NO EVENT SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO METROLOGIC FOR THE PRODUCT. METROLOGIC ALSO RESERVES THE RIGHT TO MAKE ANY CHANGES TO THE PRODUCT DESCRIBED HEREIN. Corporate Headquarters Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012-4683 Germany Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b. Munich, Germany

38

Customer Service: 1-800-ID-METRO Tel: 856-228-8100 Fax: 856-228-6673 Email: info@metrologic.com Website: www.metrologic.com Tel: 49-89-89019-0 Fax: 49-89-89019-200 Email: info@europe.metrologic.com

Page 45

APPENDIX E Notice This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Notice This Class B digital apparatus complies with Canadian ICES-003. Avertissement Cet appareil numérique de la class B est conforme à la norme NMB-003.

39