MS6720 Hand-Held Laser Scanner Installation and User's Guide, pages 28 to 36

Pages 28 to 36 of 52

The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Metrologic MS6720

Page 28

SCAN PATTERN SPECIFICATIONS (CONTINUED) Cross-Sectional Scan Pattern 2.00” Dia. [50.8mm]

3.50” Dia. [88.9mm]

MS6720 Scan Pattern at Face of Scanner

MS6720 Scan Pattern at 4.00” (101.6mm) 4.66” [118.4mm]

MS6720 Scan Pattern at 8.00” (203.6mm)

Drawings have been scaled

22

Page 29

TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms. All Interfaces

MS6720 Troubleshooting Guide SYMPTOMS

No LEDS, beep or motor spin

POSSIBLE CAUSE(S)

No power at power up

SOLUTION

Check transformer, outlet and power strip

NOTE: If it’s a direct connect scanner, the problem could be inadequate power being supplied to the scanner. It may be necessary to use a Metrologic transformer for power. Check the fuse in the MCA. 3 beeps on power up

Non-volatile RAM failure

Contact a Metrologic Rep, if the unit will not hold the programmed configuration

Continuous razz tone on power up

RAM or ROM failure

Contact a Metrologic Rep, if the unit will not function

Razz tone and red LED flash at power up

VLD failure

Contact a Metrologic Rep

Razz tone and both LEDs flash at power up

Scanner motor failure

Contact a Metrologic Rep

Unit scans, Communicates and beeps twice

Same symbol timeout set too short

Adjust same symbol timeout for a longer time

23

Page 30

TROUBLESHOOTING GUIDE (CONTINUED) All Interfaces continued SYMPTOMS

Unit goes to sleep and does not wake up

POSSIBLE CAUSE(S)

SOLUTION

IR sensor used to wake up the scanner is always sensing an object

Adjust scanner positioning so that the IR senses an object when a bar code is presented. For example; point to the ceiling and then back to the object. Disable IR sleep mode

Unit scans bar code too slowly upon waking up

Wake up requires full motor spin up for operation

Disable IR sleep mode

NOTE: Disabling the IR sleep mode allows the scanner to respond to bar codes quicker

24

Page 31

TROUBLESHOOTING GUIDE (CONTINUED) SYMPTOMS The unit powers up properly, lasers come on, but the unit does not scan and does not beep when a bar code is presented POSSIBLE CAUSE(S)/SOLUTION(S) Improper settings can be the cause for a scanner not to scan. The following would be typical examples: 1. Scanning a particular symbology that is not enabled. (UPC/EAN, Code 39, Interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default.) Verify that the type of bar code being read has been selected. 2. The scanner has been programmed for a character length lock, or a minimum length and the bar code being scanned does not satisfy the programmed criteria. Verify that the bar code that is being scanned falls into the criteria. (Typical of Non-UPC/EAN codes.) 3. The scanner scans a bar code but the scanner locks up (green LED comes on and stays on) after the first scan. The scanner is configured to support some form of host handshaking but is not receiving the signal. If the scanner is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly. 4. The scanner scans and transmits but the data is not correct at the host. Verify that the scanner’s data format matches that required by the host. Make sure that the scanner is connected to the proper host port. SYMPTOMS Scanner beeps at some bar codes and NOT for others of the same bar code symbology POSSIBLE CAUSE(S)/SOLUTION(S) 1. The print quality of the bar code is suspect. 2. The aspect ratio of the bar code is out of tolerance. 3. The bar code may have been printed incorrectly. (check digit/character/or border problem.)

25

Page 32

TROUBLESHOOTING GUIDE (CONTINUED) Keyboard Wedge Only SYMPTOMS

Unit scans the bar code but there is no data

POSSIBLE CAUSE(S)

SOLUTION

Configuration is not correct

Make sure the scanner is configured for keyboard wedge mode - Section F of the ScanSelect Guide [MLPN 00-0 2186] or MetroSet’s help files Make sure that the proper PC type AT, PS2, XT is selected

Unit scans but data is not correct

Configuration is not correct verify correct country code and data formatting are selected Adjust inter character delay Increase the inter scan code delay setting

Unit is transmitting each character twice

Configuration is not correct

Alpha characters show as lower case

Computer is in Caps Lock mode

Enable Caps Lock detect setting of the scanner to detect whether PC is operating in Caps Lock

Everything works except for a couple of characters

These characters may not be supported by that country’s key look up table

Try operating the scanner in Alt mode

26

Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings.

Page 33

TROUBLESHOOTING GUIDE (CONTINUED) RS-232 only SYMPTOMS Power-up OK Scans OK Does not communicate properly to the host

POSSIBLE CAUSE(S)

SOLUTION

Com port at the host not working or not configured Check to make sure the baud properly rate and parity of the scanner Cable not connected to and the communication port the proper com port match and the program is looking for “RS-232" data. Com port not operating properly

NOTE: Metrologic’s default of 7 data bits, space parity is usually what is expected when an IBM compatible type PC is configured for 8 data bits, no parity. SYMPTOMS

SOLUTION

Host receiving data but data does not look correct

Check that the scanner and host are configured for the same interface format

Characters are being dropped

Add some intercharacter delay to the transmitted output. This can be programmed into the scanner through ScanSelect

RS-232 Demonstration Program If an RS-232 scanner is not communicating with your IBM compatible PC, key in the following BASIC program to test that the communication port and scanner are working. This program is for demonstration purposes only. It is only intended to prove that cabling is correct, the com port is working, and the scanner is working. If the bar code data displays on the screen while using this program, it only demonstrates that the hardware interface and scanner are working. At this point, investigate whether the application software and the scanner configuration match. If the application does not support RS-232 scanners, a software wedge program that will take RS-232 data and place it into a keyboard buffer may be needed. This program tells the PC to ignore RTS-CTS, Data Set Ready (DSR) and Data Carrier Detect (DCD) signals. If the demonstration program works and yours still does not, jumper RTS to CTS and Data Terminal Reading (DTR) to DCD and DSR on the back of your PC. 10 20 30 35 40 50 60 70 100 110 32766 32767

CLS ON ERROR GOTO 100 OPEN “COM1:9600,S,7,1,CS0,DS0,CD0,LF” AS #1 PRINT “SCAN A FEW BAR CODES” LINE INPUT #1, BARCODE$ PRINT BARCODE$ K$ = INKEY$: IF K$ = CHR$(27) THEN GOTO 32766 GOTO 40 PRINT “ERROR NO.”; ERR; “ PRESS ANY KEY TO TERMINATE.” K$ = INKEY$: IF K$ = “” THAN GOTO 110 CLOSE: SYSTEM END

27

Page 34

APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and communications protocol. Scanner 6720 6720 6720 6720 6720

Version Identifier 9

11 14 15 47

Communication Protocol(s) OCIA (OCIA) IBM (46XX) RS-232 (232) Light Pen Emulation (LTPN) Keyboard Wedge (KBW)

The MS6720 Hand-Held Laser Scanner with Built-in PC Keyboard Wedge Interface is designed to be used for keyboard emulation only. However, many RS-232 programmable functions that are available in other Metrologic scanners are also available as keyboard wedge functions. The most important selectable options specific to the keyboard wedge are the following:

• • •

Keyboard Type **AT (includes IBM® PS2 models 50, 55, 60, 80) XT IBM PS2 (includes models 30, 70, 8556)

• • • •

Keyboard Country Type ** USA • Italian United Kingdom • Spanish French • Belgium German • Swiss

** Default setting. Refer to Appendix B for default settings. Refer to the ScanSelect® Scanner Programming Guide [MLPN 00-02186] or the MetroSet2 on line help for information on how to change the default settings.

28

Page 35

APPENDIX A MS6720 Design Specifications Operational Application:

Fixed Projection/Hand-Held Laser Bar Code Scanner

Light Source:

VLD 640-660nm

Laser Power:

0.681 milliwatt (peak)

Scan Speed:

0" - 4"; 0"- 8" (programmable) 0 - 101.6 mm; 0 - 203.2 mm 1000 scan lines per second

Scan Pattern:

5 fields of 4 parallel lines

Scan Lines:

20

Depth of Field:

Min Bar Width:

5.2 mil

Indicators (LED):

red = laser on, ready to scan green = good read, decoding

Beeper Operation:

3 tones or no beep)

Maintenance:

Clean output window periodically

Decode Capability:

Autodiscriminates all standard bar codes; for other symbologies call Metrologic

System Interfaces:

Keyboard Wedge, RS-232, OCIA, Light Pen, IBM 46xx

Print Contrast: Roll, Pitch, Yaw:

35% minimum reflectance difference 360°, 60°, 60°

Mechanical Dimensions: Weight: Termination:

110 mm (L) x 75 mm (W) x 160 mm (H) 450 grams ~ 1 meter retracted coil cable

Continued on next page

29

Page 36

APPENDIX A (CONTINUED) MS6720 Design Specifications Electrical Laser Class: EMC: Input Voltage: Power : Operating Current :

CDRH: Class IIa; Nach EN60825-1:1994/A11:1996 Class 1 FCC, ICES-003 and EN 55022 Class B 5VDC ± .25V 1.1 watt 225 mA typical @ 5VDC (468x – 300 mA)

Standby Current:

74 mA (468x – 165 mA)

DC Transformers:

Class 2; 5VDC @ 300 mA

Environmental Storage Temperature: Operating Temperature: Humidity:

-40°C to 60°C (-40°F to 140°F) 0°C to 35°C (32°F to 95°F) 5% to 95% relative humidity, non-condensing

Light Levels:

Up to 300 LUX

Ventilation:

None required

Shock:

1m. (40") drop

Contaminants:

Sealed to resist airborne particulate contaminants

Specifications subject to change without notice.