The text of a manual · part 2 of 6
MS6720 Hand-Held Laser Scanner Installation and User's Guide, pages 10 to 18
Pages 10 to 18 of 52
The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic MS6720
Page 10
OPERATIONAL TEST If the scanner is to receive power from an external power supply*, test the scanner before it is connected to the host system. Keyboard Wedge Scanners:
1.
Plug one end of the coil cable into the keyboard connector on the PC. Then plug the keyboard connector into the other end of the coil cable. Plug in the external transformer.
2.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. Connect AC power to the transformer.
3.
Both LEDs come on together along with the beep (the green LED only flashes).
RS-232, Light Pen, OCIA and 46xx scanners:
1.
Plug the scanner’s coil cable into the MCA (Metrologic Connector Adapter).
2.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. Plug the power supply into the MCA and the appropriate AC outlet. The outlet should be installed near the equipment and be easily accessible.
3.
Both LEDs come on together along with the beep (the green LED only flashes). The scanner can be powered in two ways: • by an External Power Supply* or • by the Host Device** i.e. the PC for the MS6720 with a Builtin PC Keyboard Wedge interface.
Caution: *To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. **To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
4
Page 11
MS6720 INSTALLATION: POWERED BY EXTERNAL POWER SUPPLY 1.
Turn off the host system.
2.
If using a communication cable, connect the cable to the correct port on the host device and the MCA (Metrologic Connector Adapter). If the host device is an IBM compatible PC with a male 9-pin serial port, connect the MCA to the port.
3.
Plug the scanner’s coil cable into the MCA.
4.
Check the AC input requirements of the power supply to make sure the voltage matches the AC outlet. The outlet should be near the equipment and be easily accessible. Plug the power supply into the MCA and the AC outlet.
5.
Turn on the host system. 6 9 Female 9 Pin
10
5 Tab Down
1 MCA
1 10 Position Modular Connector at the end of the Coil Cable
Note: a. When the scanner first receives power, the red LED will come on, the green LED will flash once and the unit will beep simultaneously. b. Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC. A software driver and correct configuration setting are also required for proper communication to occur.
Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950.
5
Page 12
MS6720 INSTALLATION: POWERED BY HOST DEVICE If the host system supplies +5VDC power to the scanner, reposition the internal jumper within the MCA (Metrologic Connector Adapter) before connecting the scanner to the host device. In addition, plug the 4 position ground jumper into the power supply connector located on the side of the MCA. 1.
Make sure the MCA is not connected to the scanner, communication cable or host and unfasten the case.
Reposition the shunt on JP1 to pins 1 and 2 and close the case.
HOST
2.
HOST
Top View of Header, Pins, and Jumper 1 1
3 JP1 +5VDC Host Power
3 JP1 Regulated +5VDC Power Supply (Factory Setting)
The factory setting of jumper 1 (JP1) is on pins 2 and 3. To direct power for the scanner from the host device, position the jumper on pins 1 and 2. Top View of Pins, and Jumper
JP2
Pin 1 of the MCA provides a connection point for various ground/shield ground configurations on different Metrologic products. Internal jumper JP2 of the MCA gives end users the option of changing pin 1 of the DB9 into a no connect (NC). Simply remove the jumper from the pins, then pin 1 of the DB9 becomes an open/no connect pin.
Factory Setting
Jumper removed for open/no connect pin
JP2 should ALWAYS be in place for OCIA applications. Continued on next page
Caution: *To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. **To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
6
Page 13
SCANNER INSTALLATION: POWERED BY HOST DEVICE (CONTINUED) 3.
Plug the 4 position ground jumper into the power supply connector.
4.
Turn off the host system
5.
If using a communication cable, connect the cable to the correct port on the host device and the MCA. If the host device is an IBM compatible with a male 9-pin serial port, connect the MCA to the port.
Power Supply Connector 6
5
9
1
Female 9-pin D
MCA
There is an optional cable (MLPN 51-51236) that is available for IBM PC applications where the MCA will not fit at the back of the computer. 6.
Plug the scanner’s coil cable into the MCA.
7. Turn on the host system.
MS6720 MCA
Coil Cable Communication Cable (Optional)
Ground Jumper (direct)
Host
Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. **To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
7
Page 14
MS6720-47 KEYBOARD WEDGE INSTALLATION TO THE PC 1.
The “Y” coil cable is terminated with a 5-pin DIN female connector on one end, and a 6-pin mini DIN male on the other. Also included with the MS6720 is an adapter cable with a 5-pin male DIN on one end and a 6-pin female mini DIN on the other to mate to a specific keyboard. According to the termination required, connect the appropriate end of the adapter cable to the coil cable, leaving the necessary termination exposed for connecting to the keyboard and the keyboard port on the PC. Refer to Appendix C for pin assignments.
2.
If the PC is on, exit the application and turn the PC off.
3.
Disconnect the keyboard from the PC.
4.
Plug one end of the coil cable into the keyboard connector on the PC. Then plug the keyboard connector into the other end of the coil cable. Plug in the external transformer. Refer to the manufacturer’s recommendation below. Connect AC power to the transformer.
5. Power up the PC. MS6720
Adapter Transformer (External)
6M “Y” Coil Cable Power Jumper (Direct)
5F Host
Manufacturer’s Recommendation: Metrologic recommends the use of an external power supply with MS6720-47 Keyboard Wedge applications. Powering** the MS6720-47 directly from the computer keyboard connector could interfere with the operation of the scanner or the computer. Not all computers supply the same current through the keyboard port, this explains why a scanner would work on one computer and not another.
Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. ) **To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
8
Page 15
MS6720 OPTIONAL STANDS Adjustable Stand [MLPN 45-45967] Contains: A. B.
Tilt/Swivel Cup Assembly [MLPN 45-45967A] Weighted Base Assembly [MLPN 45-45967B] 1B Weighted Base [MLPN 36-36765] 2B. Rotating Base [MLPN 45-45577] 3B. Wood screws, #10 Flat Head [MLPN 18-18857]
Adjustable Stand Free-Standing Installation [Kit #45-45967]
Step 1 Locate the FRONT mark on the weighted base assembly [MLPN 45-45967B]
Step 2 Align the tilt/swivel cup assembly [MLPN 45-45967A] with the weighted base assembly [MLPN 45-45967B].
Step 3 Press down firmly on the tilt/swivel cup assembly until it snaps into place on the weighted base.
9
Page 16
MS6720 OPTIONAL STANDS Adjustable Stand Hard Mount Installation [Kit #45-45967] Step 1 Remove the four screws holding the rotating base [MLPN 45-45577] to the weighted base [MLPN 36-36765]. Step 2 Note the position of the FRONT mark on the rotating base then use the rotating base as a guide to drill four pilot holes (Hard Wood - #31 drill or Soft Wood -#43 drill) in the countertop. Step 3 Secure the rotating base [MLPN 45-45577] to the countertop with the four #10 wood screws [MLPN 18-18857] provided. Step 4 Align the tilt/swivel cup assembly [MLPN 45-45967A] with the rotating base [MLPN 45-45577] as indicated below. Step 5 Press down firmly on the tilt/swivel cup assembly until it snaps into place over the rotating base.
Additional stand options available for purchase: Wall Mounting Kit [mlpn 45-45968] for use with the adjustable stand
10
Stationary Stand [MLPN 45-45429]
Page 17
SCANNER PARTS
Green and Red LED
Cable
Output Window
Adjustable Stand
Green and Red LED When the red led is on, this indicates that the laser is on. When the green LED flashes on, the scanner has read a bar code successfully. When the green light turns off, communication to the host is complete. The green LED blinks while the scanner is waking up from an IR sensor timeout. The LED’s are also used as diagnostic indicators and mode indicators. Output Window Laser light emits from this aperture. Adjustable stand Designed to provide an adequate distance for scanning between the scanner face and counter at all times. When fully tilted, the face of the scanner remains a full five inches from the counter. Refer to page 10 for available kits. Cable This cable is terminated with a 10-pin modular connector, which attaches to the MCA951. The Keyboard Wedge unit has a “Y” coil cable terminated with a 5-pin female on one end, a 6-pin male and a 4-pin locking connector for power input (power jumper). An adapter is included with a 5-pin male DIN on one end and a 6pin female mini DIN on the other to mate to a specific keyboard. Refer to Appendix C for pin assignments.
11
Page 18
AUDIBLE INDICATORS When the MS6720 scanner is in operation, it provides audible feedback. These sounds indicate the status of the scan and scanner. Four settings are available for the tone of the beep. To change the tone, refer to the ScanSelect® Programming Guide [MLPN 00-02186] or the help files provided with MetroSet2. One Beep When the scanner first receives power, both LEDs come on together along with a beep (the green LED only flashes). After the scanner performs this startup sequence, the scanner is ready to scan. When the scanner successfully reads a bar code, the green light will flash and beep once (if programmed to do so). If the scanner does not beep once and the green light does not flash, then the bar code has not been successfully read. Razzberry Tone This tone is a failure indicator. Refer to failure modes page 13. Three Beeps - after power up
When entering the program mode, the green LED will flash while the scanner simultaneously beeps three times. The green LED will continue to flash until the unit exits program mode. Upon exiting program mode, the scanner will beep three times and the green LED will stop flashing. When configured, 3 beeps can also indicate a communications timeout during normal scanning mode.
12