For the Metrologic MS6720

Page 1 read from a scan by OCR; it may hold reading errors

@ Metrologic’

METROLOGIC INSTRUMENTS, INC. MS6720 Hand-Held Laser Scanner Installation and User’s Guide

Page 2

This page is a scan with no text; see it in the PDF.

Page 3

LOCATIONS CORPORATE HEADQUARTERS North America

Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012-4683

Customer Service: 1-800-ID-METRO Tel: 856-228-8100 Fax: 856-228-6673 Email: info@metrologic.com Internet: www.metrologic.com

Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b. Munich, Germany

Tel: +49 89 89019 0 Fax: +49 89 89019 200 Email: info@europe.metrologic.com Germany Email: info@de.metrologic.com

Spain

Metrologic Eria lbérica SL Julián Camarillo 29, D-1 Edificio Diapasón 28037 Madrid

Tel: +34 913 272 400 Fax: +34 913 273 829 Email: info@es.metrologic.com

Italy

Metrologic Instruments Italia srl Via Emilia 70 40064 Ozzano dell’Emilia (BO)

Tel: +39 0 51 6511978 Fax: +39 0 51 6521337 Email: info@it.metrologic.com

France

Metrologic Eria France SA 69 Rue de la Belle Etoile ZI Paris Nord II, BP 50057 95947 – ROISSY CDG CEDEX

Tel: +33 (0) 1 48.63.78.78 Fax: +33 (0) 1 48.63.24.94 Email: info@fr.metrologic.com

United Kingdom

Metrologic Instruments UK Limited 58 Tempus Business Centre Kingsclere Road, Basingstoke Hampshire RG21 6XG

Tel: +44 (0) 1256 365900 Fax: +44 (0) 1256 365955 Email: info@uk.metrologic.com

Singapore

Metrologic Asia (Pte) Ltd No. 8 Kaki Bukit Place 4th Floor Singapore 416186

Tel: 65-6842-7155 Fax: 65-6842-7166 Email: info@sg.metrologic.com

China

Metro (Suzhou) Technologies Co., Ltd. 221 Xing Hai Street Suzhou Industrial Park Suzhou, China 215021

Tel: 86-512-62572511 Fax: 86-512-62571517 Email: info@cn.metrologic.com

Japan

Metrologic Japan Co., Ltd. Matsunoya Building, 6 Floor 3-14-8 Higashiueno Taitou-Ku, Tokyo 110-0015 Japan

Tel: 81-03-3839-8511 Fax: 81-03-3839-8519 Email: info@jp.metrologic.com

Brazil

Metrologic do Brasil Ltda. Rua da Paz 2059 CEP 04713-002 Chácara Santo Antônio São Paulo, SP, Brasil

Tel: 55-11-5182-8226 Fax: 55-11-5182-8315 Email: info@br.metrologic.com

Outside Brazil

Metrologic South America Rua da Paz 2059 CEP 04713-002 Chácara Santo Antônio São Paulo, SP, Brasil

Tel: 55-11-5182-7273 Fax: 55-11-5182-7198 Email: info@sa.metrologic.com

EUROPEAN HEADQUARTERS Germany, Middle East and Africa

ASIA

SOUTH AMERICA

Copyright © 2002 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentioned in this document are trademarks of their respective companies.

ii

Page 4

TABLE OF CONTENTS Introduction................................................................................................................1 Scanner and Accessories ............................................................................................2 Quick Start .................................................................................................................3 Operational Test.........................................................................................................4 MS6720 Installation: Powered by External Power Supply ........................................5 MS6720 Installation: Powered by Host Device .........................................................6 MS6720-47 Keyboard Wedge Installation to the PC .................................................8 MS6720 Optional Stands ...........................................................................................9 Scanner Parts............................................................................................................11 Audible Indicators....................................................................................................12 Failure Modes ..........................................................................................................13 Visual Indicators ......................................................................................................14 Scanner Labels .........................................................................................................15 Maintenance.............................................................................................................15 Depth of Field Specifications Normal Depth of Field.........................................................................................16 Short Depth of Field ............................................................................................17 Extended Depth of Field......................................................................................18 Optional Depth of Field.......................................................................................19 Normal Depth of Field.........................................................................................20 Short Depth of Field ............................................................................................20 Scan Pattern Specifications Projection Axis ....................................................................................................21 Omnidirectional Scan Volume.............................................................................21 Cross-Sectional Scan Pattern...............................................................................22 Troubleshooting Guide ............................................................................................23 Applications and Protocols ......................................................................................28 Appendix A Design Specifications ..........................................................................................29 Appendix B Default Settings ...................................................................................................31 iii

Page 5

TABLE OF CONTENTS Appendix C Pin Assignments for the Coil Cable.....................................................................35 Pin Assignmentsf or the MCA951.......................................................................36 Pin Assignmentsf or the MS6720-47 Keyboard Wedge Cable ............................37 Appendix D Limited Warranty ................................................................................................38 Appendix E Notices.................................................................................................................39 Appendix F Patents .................................................................................................................41 Index ........................................................................................................................42 iv

Page 6

This page is a scan with no text; see it in the PDF.

Page 7

INTRODUCTION The MS6720 is the first laser bar code scanner to truly bridge the gap between omnidirectional fixed projection and hand-held scanners. It incorporates fixed projection performance and patented 20-line scan pattern into the comfortable, ergonomic styling of our popular hand-helds. The MS6720 utilizes a unique, patented infrared sensor and control scheme for hands-free projection scanning and fatigue reduced hand-held operation. Whether operators choose to present small items to the scanner or transport the lightweight scanner to bulkier items, the compact size and comprehensive scan pattern make the MS6720 the perfect choice for many applications. For increased flexibility there are three optional stands available. The stationary stand is ideal for applications where the MS6720 is being used as a hand-held scanner. Or if a customer application requires more in stand scanning Metrologic’s adjustable stand provides 7 rotational and 9 tilting positions while still providing the option for hand-held scanning. If countertop space is an issue there is an optional bracket for a wall mounting that can be used with the adjustable stand cup. The MS6720 features both short-range and long-range activation, userfriendly programming, reliability and versatility. Operators are sure to appreciate the convenience and flexibility of the MS6720.

Scanner

Interface

MS6720-9 MS6720-11 MS6720-14 MS6720-15 MS6720-47

OCIA (OCIA) IBM (46XX) RS-232 (232) Light Pen Emulation (LTPN) Keyboard Wedge (KBW)

1

Page 8

SCANNER AND ACCESSORIES The following is a list of parts that may or may not be included in a MS6720 kit. •

MS6720 Hand-Held Laser Scanner

•

AC to DC Power Transformer – Regulated 5VDC @ 300 mA output • One of the following options may be included: • 120V United States [MLPN 46-46010] • 220V Continental European [MLPN 46-46009] • 240V United Kingdom [MLPN 46-46008]

•

Stand • One of the following options may be included: • Stationary Stand [MLPN 45-45429] • Adjustable Stand [MLPN 45-45967] • Wall Mounting Kit [MLPN 45-45968]

•

Installation and User’s Guide [MLPN 00-02368]

•

ScanSelect® Scanner Programming Guide [MLPN 00-02186] or MetroSet2 CD

RS-232, Light Pen, some OCIA and some 46xx •

MCA (Metrologic Connector Adapter) [MLPN MCA951]

•

For direct connect application (No Power Transformer) 4 position MCA ground jumper [MLPN 51-51191]

Keyboard Wedge Scanners: •

Adapter Cable with a 5-pin DIN male connector on One end and a 6-pin mini DIN female connector On the other [MLPN 45-45927]

•

For direct connect application (No Power Transformer) 4 position direct power jumper [MLPN 52-52332]

Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic’s Customer Service Department at 1-800-ID-METRO or 1-800-436-3876.

2

Page 9

QUICK START 1.

Plug in the scanner. The red LED will come on, the green LED will flash once and the unit will beep simultaneously.

2.

The scanner is shipped from the factory programmed with default settings. To configure the MS6720 scanner to meet the host system’s specific needs, refer to the ScanSelect® Programming Guide [MLPN 00-02186] or the help files provided with MetroSet2 for instructions on how to enter the program mode and to select the appropriate bar codes. Note: Any time the Load Defaults bar code is scanned the MS6720 is configured for an RS-232 interface. If a RS-232 is not being used, scan at least one other bar code to enable Keyboard Wedge, OCIA, Light Pen or 46xx.

3