Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 4

MS5100 Eclipse Series Installation and User's Guide, pages 21 to 30

Pages 21 to 30 of 40

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Metrologic MS5145

Page 21

TROUBLESHOOTING GUIDE (CONTINUED) SYMPTOMS

POSSIBLE CAUSE(S)

Scanner beeps at some bar codes and NOT for others of the same bar code symbology

The bar code may have been printed incorrectly

Check if it is a check digit/character/or border problem.

Scanner beeps at some bar codes and NOT for others of the same bar code symbology

The scanner is not configured correctly for this type of bar code

Check if check digits are set properly.

Scanner beeps at some bar codes and NOT for others of the same bar code symbology

The minimum symbol length setting does not work with the bar code

Check if the correct minimum symbol length is set.

The unit scans the bar code but there is no data

Configuration is not correct

Make sure the scanner is configured for the appropriate communication mode.

Configuration is not correct

Make sure that the proper PC type AT, PS2 or XT is selected. Verify correct country code and data formatting are selected. Adjust intercharcter delay.

The unit scans but the data is not correct (Keyboard Wedge)

SOLUTION

17

Page 22

TROUBLESHOOTING GUIDE (CONTINUED) SYMPTOMS The unit is not transmitting each character (Keyboard Wedge)

POSSIBLE CAUSE(S)

SOLUTION

Configuration is not correct

Increase interscan code delay setting. Adjust whether the F0 break is transmitted. It may be necessary to try this in both settings.

Alpha characters show as lower case (Keyboard Wedge)

Computer is in Caps Lock mode

Enable Caps Lock detect setting of the scanner to detect whether the PC is operating in Caps Lock.

Everything works except for a couple of characters (Keyboard Wedge)

These characters may not be supported by that country’s key lookup table

Try operating the scanner in Alt mode.

Power-up OK and scans OK but does not communicate properly to the host

Com port at the host is not working or configured properly or Cable not connected to the proper comm port

Check to make sure that the baud rate, data bits, stop bits and parity of the scanner and the communication port match and the program is looking for “RS-232” data.

The host is receiving data but the data does not look correct

The scanner and host may not be configured for the same interface font

Check that the scanner and the host are configured for the same interface font.

Characters are being dropped

Scanner may not be set for sufficient Intercharacter delay

Add some inter-character delay to the transmitted output by using the MetroSelect Programming Guide MLPN 2544.

18

Page 23

RS-232 DEMONSTRATION PROGRAM If an RS-232 scanner is not communicating with your IBM compatible PC, key in the following BASIC program to test that the communication port and scanner are working. This program is for demonstration purposes only. It is only intended to prove that cabling is correct, the communication port is working, and the scanner is working. If the bar code data displays on the screen while using this program, it only demonstrates that the hardware interface and scanner are working. At this point, investigate whether the application software and the scanner configuration match. If the application does not support RS-232 scanners, a software wedge program that will take RS-232 data and place it into a keyboard buffer may be needed. This program tells the PC to ignore RTS-CTS, Data Set Ready (DSR) and Data Carrier Detect (DCD) signals. If the demonstration program works and yours still does not, jumper RTS to CTS and Data Terminal Ready (DTR) to DCD and DSR on the back of your PC. 10 20 30 35 40 50 60 70 100 110 32766 32767

CLS ON ERROR GOTO 100 OPEN “COM1:9600,S,7,1,CS0,DS0,CD0,LF” AS #1 PRINT “SCAN A FEW BAR CODES” LINE INPUT #1, BARCODE$ PRINT BARCODE$ K$ = INKEY$: IF K$ = CHR$(27) THEN GOTO 32766 GOTO 40 PRINT “ERROR NO.”; ERR; “ PRESS ANY KEY TO TERMINATE.” K$ = INKEY$: IF K$ = “” THEN GOTO 110 CLOSE: SYSTEM END

MAINTENANCE Smudges and dirt on the window of the scanner can interfere with proper scanning. Therefore, the output window will need occasional cleaning. 1.

Spray glass cleaner onto a lint-free, non-abrasive cleaning cloth.

2.

Gently wipe the scanner window.

19

Page 24

APPENDIX A Specifications

OPERATIONAL Light Source

Visible Laser Diode 650 nm ± 10 nm

Laser Power (peak)

<1.0 mW

Depth of Scan Field (for 13mil at Default)

0 mm – 140 mm (0” – 5.5”)

Scan Speed

72 ± 2 scan lines per second

Scan Pattern

Single scan line

Minimum Bar Width

0.102 mm (4.0 mil)

Decode Capability

Autodiscriminates all standard bar codes; for others call Metrologic

System Interfaces

RS232, Keyboard Wedge, Light Pen Emulation, IBM 468X/469X, OCIA, Stand Alone Keyboard, USB

Print Contrast

35% minimum reflectance difference

Number Characters Read

Up to 80 data characters (Maximum number will vary based on symbology and density)

Roll, Pitch, Yaw

42°, 68°, 52°

Beeper Operation

7 tones or no beep

Indicators (LED)

Green = laser on, ready to scan Red = good read

MECHANICAL Length

170 mm (6.7”)

Width-Handle Width-Head Height-Head Height-Handle

39 mm (1.5”) 63 mm (2.5”) 35 mm (1.4”) 31 mm (1.2”)

Weight

97 g (3.4 oz)

Cable

Long bend relief PowerLink Cable (see Page 2)

20

Page 25

APPENDIX A (CONTINUED) ELECTRICAL Input Voltage

5 VDC ± 0.25 V

Power - Operating

0.675 mW

Current - Operating

135 mA peak @ 5 VDC

DC Transformers

Class 2; 5.2 V @ 650 mA

UL

UL listed for US and Canada; UL 60950, C22.2 No. 60950

Laser Class

CDRH: Class II; IEC 60825-1: 1993+A1:1997+A2:2001 Class 1

EMC

Class B: FCC Part 15, ICES-003, European Union Directive

ENVIRONMENTAL Operating Temperature

0°C to 40°C (32°F to 104°F)

Storage Temperature

-40°C to 60°C (-40°F to 140°F)

Humidity

5% to 95% relative humidity, non-condensing

Light Levels

Up to 4842 Lux (450 footcandles)

Shock

Designed to withstand 1.5 m (5’) drops

Contaminants

Sealed to resist airborne particulate contaminants

Ventilation

None required

21

Page 26

APPENDIX B Default Settings Many functions of the scanner can be “programmed” – that is, enabled or disabled. The scanner is shipped from the factory programmed to a set of default conditions. The default parameter of the scanner has an asterisk (*) in the charts on the following pages. If an asterisk is not in the default column then the default setting is OFF or DISABLED. Every communication does not support every parameter. If the communication supports a parameter listed in the charts on the following pages, a check mark will appear. Parameter Normal Scan Mode (Blink) Continuous Scan Mode UPC/EAN

Default

OCIA

RS232

Light Pen

IBM 46XX

KBW

USB

*

9

9

9

9

9

9

9

9

9

9

9

9

*

9

9

9

9

9

9

UPC-A

*

9

9

9

9

9

9

EAN-8

*

9

9

9

9

9

9

EAN-13

*

9

9

9

9

9

9

UPC-E

*

9

9

9

9

9

9

Code 128

*

9

9

9

9

9

9

Code 93

*

9

9

9

9

9

9

Codabar Interleaved 2 of 5 (ITF) MOD 10 check on ITF

*

9

9

9

9

9

9

*

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

Full ASCII Code 39

9

9

9

9

9

9

Telepen

9

9

As Code 39

9

9

9

Matrix 2 of 5

9

9

9

9

9

Airline 2 of 5 (13)

9

9

9

9

9

Airline 2 of 5 (15)

9

9

9

9

9

Dual Codabar

9

9

9

9

9

DK Plessey

9

9

9

9

9

STD 2 of 5

9

9

9

9

9

MSI Plessey

9

9

As Code 39

9

9

9

Double Border

9

9

9

9

9

9

Small Border MOD 43 Check on Code 39 MSI-Pessey 10/10 Check Digit MSI-Plessey MOD 10 Check Digit

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

Code 11 Code 39

22

*

*

Page 27

APPENDIX B (CONTINUED) Parameter

Default

OCIA

RS232

Light Pen

IBM 46XX

KBW

USB

9

9

9

9

9

9

ITF Symbol Lengths Minimum Symbol Length Symbol Length Lock

Variable

9

9

9

9

9

9

3

9

9

9

9

9

9

None

9

9

9

9

9

9

Bars High as Code 39 Spaces High as Code 39 Bars High as Scanned Spaces High as Scanned Low Speed Option Toggle on Decode 10x Narrow Element 50x Narrow Element Poll Light Pen Source Beeper Tone Beep/Transmit Sequence Communication Timeout Razzberry tone on Timeout Three beeps on Timeout Same symbol rescan timeout 100 msecs Same symbol rescan timeout 200 msecs Same symbol rescan timeout 500 msecs Same symbol rescan timeout 1200 msecs Same symbol rescan timeout 2000 msecs No Same Symbol Timeout Extra Same Symbol Check Normal Same Symbol Check Infinite Same Symbol Timeout Number of scan buffers (maximum)

*

9

9

9

Paraf Support ITF

9 9 9 9

Normal Before transmit

9

9

9 9 9 9 9 9

9

9

9

9 none

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

*

*

*

2

9

23

Page 28

APPENDIX B (CONTINUED) Parameter

Default

OCIA

RS232

Light Pen

IBM 46XX

KBW

Inter-character delay Programmable in 1 msec steps (max 255 msecs)

1 msecs 10 msecs in KBW

9

9

9

9

9

*

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

*

9

9

9

9

9

*

9

9

9

9

9

*

9

9

9

9

9

9

9

9

9

9 9 9

9 9 9 9 9 9 9 9 9 9

9 9 9 9

9 9 9

Transmit UPC-A check digit Transmit UPC-E check digit Expand UPC-E Convert UPC-A to EAN-13 Transmit lead zero on UPC-E Transmit UPC-A number system Transmit UPC-A Manufacturer ID# Transmit UPC-A Item ID# Transmit Codabar Start/Stop Characters CLSI Editing (Enable) Transmit Mod 10/ITF Transmit MSI-Plessy Parity Baud Rate 8 Data Bits 7 Data Bits Stop Bits Manufacturer’s ID Scanner ID Transmit Sanyo ID Characters Nixdorf ID Aim ID Sineko ID Sni Beetle ID Tec ID NCR ID Rochford Thomson ID Family Dollar ID LRC Enabled UPC Prefix UPC Suffix

24

Space 9600 * 2

USB

9 9 9 9

9 9

9

9

9

9 9 9 9 9 9 9 9 9 9 9

9 9 9 9 9 9 9 9 9 9 9

9 9 9 9 9 9 9 9 9 9 9

Page 29

APPENDIX B (CONTINUED) OCIA

RS232

Light Pen

IBM 46XX

Parameter

Default

Carriage Return Line Feed-Disabled by default in KBW Tab Prefix Tab Suffix “C” prefix “I” prefix STX prefix ETX suffix “DE” Disable Command “FL” Laser Commands DTR Handshaking support RTS/CTS Handshaking Character RTS/CTS Message RTS/CTS XON/XOFF Handshaking ACK/NAK Two Digit Supplements Five Digit Supplements Bookland (978) 977 (2 digit) Supplemental Requirement Supplements are not Required Two Digit Redundancy Five Digit Redundancy Number System 5 Supplements FR. Bookland (378) 434/439 Supplement 100 msec to Find Supplement Programmable in 100 msec steps (max 800 msec) Programmable Prefix Characters

*

9

*

9

9

9 9 9 9 9 9

9

9 9 9 9 9 9

KBW

USB

9

9

9 9 9 9 9 9

*

9 9 9

9

As Code 39

9

9

9

9

9

As Code 39

9

9

9

9

9

As Code 39

9

9

9

9

9

9

9

9

9

*

9

9

9

9

9

9

*

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9 9

9 9

9 9

9 9

9 9

9 9

9

9

9

9

9

9

9

9

*

10 avail

9

25

Page 30

APPENDIX B (CONTINUED) Parameter Coupon Code 128 Programmable Code Lengths Programmable Suffix Characters Prefixes for Individual Code types Inter Scan-Code Delay Programmable (100 µsec steps) Function/Control Key Support Minimum Element Width Programmable in 5.6 µsec steps Country Coded Keyboards

26

Default

7 avail 10 avail

OCIA

RS232

Light Pen

IBM 46XX

KBW

USB

9

9

As Code 39

9

9

9

9

9

9

9

9

9

9

9

9

9

9

9

800 µsec

1 msec. US

9 9

9

9

9

9