For the Metrologic MS5145

Page 11

USB SCANNER INSTALLATION 1.

Connect the 10-pin RJ45 plug of the PowerLink cable into the jack on the MS5145 USB scanner. Note: The MS5145 USB scanner will receive power directly from the host system; no external power supply is required.

2.

Connect the USB connector of the PowerLink cable into the USB port of the host system.

n

3.

o

When the MS5145 is ready to scan, the green LED will turn on, the red LED will flash and the scanner will beep once.

7

Page 12

DISCONNECTING THE POWERLINK CABLE FROM THE SCANNER Before removing the cable from the scanner, Metrologic recommends that the power on the host system is off and the power supply has been disconnected from the PowerLink cable.

o& p q n 1.

Locate the small ‘pin-hole’ on the back of the scanner.

2.

Bend an ordinary paperclip into the shape shown above.

3.

Insert the paperclip (or other small metallic pin) into the small ‘pin-hole’.

4.

You will hear a faint ‘click’. Pull gently on the strain-relief of the PowerLink cable and it will slide out of the scanner.

8

Page 13

SCANNER PARTS

1.

Green & Red LEDs The MS5145’s laser pulses on and off when no bar code is presented, and stays on when it senses a bar code. The green LED remains on during normal pulse and scanning operation, and it blinks during power save mode. On a successful read of a bar code, the red LED will flash and the scanner will beep once. The LEDs are also used as diagnostic indicators and mode indicators.

2.

Output Window Laser Light emits from this aperture.

3.

PowerLink Cable The 10-pin modular plug on the PowerLink cable connects into the 10-pin modular jack on the MS5145. 9

Page 14

AUDIBLE INDICATORS When the MS5145 scanner is operational, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). To change the tone, refer to the Configuration Guide. One Beep – on power up The green LED will turn on, then the red LED will flash and the scanner will beep once. The red LED will remain on for the duration of the beep. The scanner is now ready to scan.

One Beep – during operation When the scanner successfully reads a bar code, the red LED will flash and the scanner will beep once (if programmed to do so). If the scanner does not beep once and the red light does not flash, then the bar code has not been successfully read.

Three Beeps – during operation When entering the program mode, the red LED will flash while the scanner simultaneously beeps three times. The red LED will continue to flash until the unit exits program mode. Upon exiting program mode, the scanner will beep three times and the red LED will stop flashing. When configured for communication timeout, 3 beeps during operation will indicate that a communication timeout has occurred.

Three Beeps – on power up This is a failure indicator. Refer to the Failure Modes section of this guide on page 11.

Razzberry Tone This is a failure indicator or an invalid code read during program mode. Refer to the Failure Modes section of this guide on page 12.

10

Page 15

VISUAL INDICATORS There is a red LED and a green LED on the MS5145. When the scanner is on, the activity of the LEDs indicates the status of the current scan and the scanner. Green and Red LEDs are off The LEDs will not be illuminated if the scanner is not receiving power from the host or transformer.

Steady Green Indicates normal pulse or continuous laser operation. Accompanied by a razzberry tone, it indicates that an invalid bar code has been scanned.

Flashing Green After a period of inactivity, the ON time of the pulsing laser will be shortened. During this time the green LED will flash. This indicates that the scanner is in a power saver mode. When a bar code enters the laser field, the scanner will wake up and return to normal pulse mode.

Steady Green and Single Red Flash When the scanner successfully reads a bar code, the red LED will flash and the scanner will beep. If the red LED does not flash and the scanner does not beep, then the bar code has not been successfully read.

Steady Green and Steady Red After a successful read, the scanner transmits the data to the host device. Some communication modes require that the host inform the scanner when data is ready to be received. If the host is not ready to accept the information, the scanner’s red LED will remain on until the data can be transmitted.

Steady Green and Continuous Flashing Red When entering the program mode, the red LED will flash, the green LED will turn on and the scanner will beep three times. The red LED will continue to flash and the green LED will stay on until the unit exits the program mode. 11

Page 16

FAILURE MODES One Razzberry Tone on Power-up This indicates the scanner has experienced a laser or flipper subsystem failure. Return the unit for repair to a Metrologic Authorized Service Center.

Continuous Razzberry Tone with all LEDs off If, upon power up, the scanner emits a continuous razzberry tone, then the scanner has an experienced an electronic failure. Return the unit for repair to a Metrologic Authorized Service Center. Three Beeps – on power up If the scanner beeps 3 times on power up then, the non-volatile memory (NovRAM) that holds the scanner configuration has failed. Return the unit for repair to a Metrologic Authorized Service Center.

12

Page 17

SCAN AREA

Minimum Bar Code Element Width A

B

C

D

E

F mm

.10

.12

.17

.26

.33

.66 mils

4.1

4.8

6.8

10.4

13

26

13

Page 18

LABELS Each scanner has one label on the underside of the unit. This label has the model number, date of manufacture, serial number, laser and caution information. The following is an example of this label.

Patent Information-See Manual FCC and ICES-003 Information-See Manual Warranty VOID if case opened. Contains no user serviceable components. Complies with 21 CFR 1040.10 & 1040.11 IEC 60825-1:1993+A2:2001

14

Page 19

TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative to preserve the limited warranty terms on page 31. SYMPTOMS

POSSIBLE CAUSE(S)

SOLUTION

No power is being supplied to the scanner

Check transformer, outlet and power strip. Make sure the cable is plugged into the scanner.

No power is being supplied to the scanner from host

Some host systems cannot supply enough current to power the MS5145. Use the proper power supply.

3 beeps on power up

Non-volatile RAM failure

Contact a Metrologic Representative, if the unit will not hold the programmed configuration.

Continuous razz tone on power up

RAM or ROM failure

Contact a Metrologic Representative.

Razz tone at power up

VLD failure or a Scanner flipper failure

Contact a Metrologic Representative.

Unit scans, Communicates and beeps twice

Same Symbol timeout set too short

Adjust same symbol time out for a longer time.

The unit powers up but does not beep

Beeper disabled. No tone selected

Enable beeper. Select tone.

No LEDs, beep or laser line

No LEDs, beep

15

Page 20

TROUBLESHOOTING GUIDE (CONTINUED) SYMPTOMS

POSSIBLE CAUSE(S)

SOLUTION

The unit powers up, but does not scan

Scanning a particular symbology that is not enabled

UPC/EAN, Code 39, Interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify that the type of bar code being read has been selected.

The unit powers up, but does not scan and/or beep

The scanner has been programmed for a character length lock, or a minimum length and bar code being scanned does not satisfy the programmed criteria

Verify that the bar code that is being scanned falls into the criteria (Typical of NonUPC/EAN codes.) The scanner defaults to a minimum of 3 character bar code.

The unit scans a bar code, but locks up after the first scan and the red LED stays on

The scanner is configured to support some form of host handshaking but is not receiving the signal

If the scanner is setup to support ACK/NAK,RTS/CTS, XON/XOFF) or D/E, verify that the host cable and host are supporting the handshaking properly.

The unit scans, but the data transmitted to the host is incorrect

The scanner’s data format does not match the host system requirements

Verify that the scanner’s data format matches that required by the host. Make sure that the scanner is connected to the proper host port.

Scanner beeps at some bar codes and NOT for others of the same bar code symbology

16

The print quality of the bar code is suspect Or The aspect ratio of the bar code is out of tolerance

Check print mode. The type of printer could be the problem. Change print settings. For example change to econo mode or high speed.