For the Metrologic MS5145

Page 31

APPENDIX C Scanner Pinout Connections The MS5145 scanner interface terminates to a 10-pin modular jack. The serial # label indicates the interface enabled when the scanner is shipped from the factory.

MS5145-41 (RS-232C & LTPN) Pin 1 2 3 4 5 6 7 8 9 10

Function Ground RS-232 Transmit Output RS-232 Receive Input RTS Output CTS Input DTR Input/LTPN Source Reserved LTPN Data +5VDC Shield Ground

MS5145-9 (OCIA) Pin 1 2 3 4 5 6 7 8 9 10

Function Ground No Connection No Connection RDATA RDATA Return Clock In Clock Out Clock in Return/Clock out Rtrn +5VDC Shield Ground

1

10

MS5145-11 (IBM 468X/469X) Pin 1 2 3 4 5 6 7 8 9 10

Function Ground RS-232 Transmit Output RS-232 Receive Input RTS Output CTS Input DTR Input IBM B-Transmit IBM A+ Receive +5VDC Shield Ground

Continued next page

27

Page 32

APPENDIX C (CONTINUED)

MS5145-37 (USB/KBW) Pin 1

10

1 2 3 4 5 6 7 8 9 10

Function Ground DD+ PC DATA PC CLOCK KB CLOCK PC+5V/V_USB KB DATA V_EXT Shield Ground

Cable Connector Configurations • RS232 PowerLink Cable with built in power jack [ MLPN 55-55000A ] The RS232 PowerLink cable is terminated with a 9-pin D-Type connector to the host. “Standard” PowerLink cable 9

6 9-Pin D-Type Connector

•

1

Pin 1 2 3 4 5 6 7 8 9

Function Shield Ground RS-232 Transmit Output RS-232 Receive Input DTR Input/Light Pen Source Power/Signal Ground Light Pen Data CTS Input RTS Output +5VDC*

If a PowerLink power supply is plugged into the PowerLink cable, +5V will NOT be available on this pin. This pin is used when the host is supplying +5V to the scanner.

Continued next page

28

5

Page 33

APPENDIX C (CONTINUED) • Keyboard Wedge PowerLink and Adapter Cable [MLPN 55-55002A] The Keyboard Wedge PowerLink cable is a “Y” cable terminated with a 5-pin DIN female connector on one end, and a 6-pin mini DIN male on the other. 4

2

5

2

3

4

1

1 3 6 5

Keyboard Wedge PowerLink Cable

5-Pin DIN, Female

6-Pin DIN, Male

Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other. 5 3

2

4

2

1

1

3

4 5 6

5-Pin Din, Male

Adapter Cable

6-pin Mini Din, Female

According to the termination required, connect the appropriate end of the adapter cable to the PowerLink cable, leaving the necessary termination exposed for connecting to the keyboard and the keyboard port on the PC. The pin assignments of the Keyboard Wedge PowerLink and adapter cable are as follows:

Pin 1 2 3 4 5

POWERLINK CABLE

ADAPTER CABLE

5-pin Female DIN

5-pin Male DIN

Function Keyboard Clock Keyboard Data No Connect Power Ground +5 Volts DC

Pin 1 2 3 4 5

6-pin Male Mini-DIN Pin 1 2 3 4 5 6

Function PC Data No Connect Power Ground +5 Volts DC PC Clock No Connect

Function PC Clock PC Data No Connect Power Ground +5 Volts DC 6-pin Female Mini-DIN

Pin 1 2 3 4 5 6

Function Keyboard Data No Connect Power Ground +5 Volts DC Keyboard Clock No Connect 29

Page 34

APPENDIX C (CONTINUED) • USB PowerLink cable [ MLPN 55-55165A ] The USB PowerLink cable is terminated with an USB A type connector. USB PowerLink cable Pin

USB A Type Connector

30

1 2 3 4

Function PC+5V/V_USB DD+ Ground

Page 35

APPENDIX D Warranty and Disclaimer Limited Warranty The MS5145 scanner is manufactured by Metrologic at its Suzhou, China facility. The MS5145 scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS5100 scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S. Federal, state and local laws, regulations and ordinances pertaining to their production and labeling. This warranty is limited to repair, replacement of Product or refund of Product price at the sole discretion of Metrologic. Faulty equipment must be returned to Metrologic. To do this, contact Metrologic’s Customer Service/Repair Department to obtain a Returned Material Authorization (RMA) number. In the event that it is determined the equipment failure is covered under this warranty, Metrologic shall, at its sole option, repair the Product or replace the Product with a functionally equivalent unit and return such repaired or replaced Product without charge for service or return freight, whether distributor, dealer/reseller, or retail consumer, or refund an amount equal to the original purchase price. This limited warranty does not extend to any Product which, in the sole judgement of Metrologic, has been subjected to abuse, misuse, neglect, improper installation, or accident, nor any damage due to use or misuse produced from integration of the Product into any mechanical, electrical or computer system. The warranty is void if the case of Product is opened by anyone other than Metrologic’s repair department or authorized repair centers. THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES, EITHER EXPRESS OR IMPLIED, AND SPECIFICALLY EXCLUDES, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE UNDER THE UNIFORM COMMERCIAL CODE, OR ARISING OUT OF CUSTOM OR CONDUCT. THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE EXCLUSIVE AND IN LIEU OF ANY OTHER RIGHTS OR REMEDIES. IN NO EVENT SHALL METROLOGIC BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES, INCIDENTAL DAMAGES, DAMAGES TO PERSON OR PROPERTY, OR EFFECT ON BUSINESS OR PROPERTY, OR OTHER DAMAGES OR EXPENSES DUE DIRECTLY OR INDIRECTLY TO THE PRODUCT, EXCEPT AS STATED IN THIS WARRANTY. IN NO EVENT SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO METROLOGIC FOR THE PRODUCT. METROLOGIC RESERVES THE RIGHT TO MAKE ANY CHANGES TO THE PRODUCT DESCRIBED HEREIN.

North America Headquarters Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012-4683 China Facility Metro (Suzhou) Technologies Co., Ltd 221 Xing Hai Street Suzhou Industrial Park Suzhou, China 215021

Customer Service: 1-800-ID-METRO Tel: 856-228-8100 Fax: 856-228-6673 Email: info@metrologic.com Website: www.metrologic.com Tel: 86-512-2572511 Fax: 86-512-2571517 Email: info@cn.metrologic.com

31

Page 36

APPENDIX E Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency and, if not installed and used in accordance with the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • • • •

Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Notice This Class B digital apparatus complies with Canadian ICES-003.

Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Under no circumstances should the customer attempt to service the laser scanner. Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional. Never open the scanner in an attempt to look into the device. Doing so could result in hazardous laser light exposure. The use of optical instruments with the laser equipment will increase eye hazard.

Remarque Cet appareil numerique de la class B est conforme à la norme NMB-003 du Canada.

Attention L'emploi de commandes, réglages ou procédés autres que ceux décrits ici peut entraîner de graves irradiations. Le client ne doit en aucun cas essayer d'entretenir lui-même le scanner ou le laser. Ne regardez jamais directement le rayon laser, même si vous croyez que le scanner est inactif. N'ouvrez jamais le scanner pour regarder dans l'appareil. Ce faisant, vous vous exposez à une rayonnement laser mortel. L'emploi d'appareils optiques avec cet équipement laser augmente le risque d'endommagement de la vision.

Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann eine lebensgefährliche Laserstrahlung hervorrufen. Der Kunde sollte unter keinen Umständen versuchen, den Laser-Scanner selbst zu warten. Sehen Sie niemals in den Laserstrahl, selbst wenn Sie glauben, daß der Scanner nicht aktiv ist. Öffnen Sie niemals den Scanner, um in das Gerät hineinzusehen. Wenn Sie dies tun, können Sie sich einer lebensgefährlichen Laserstrahlung aussetzen. Der Einsatz optischer Geräte mit dieser Laserausrüstung erhöht das Risiko einer Sehschädigung.

Attenzione L’utilizzo di sistemi di controllo, di regolazioni o di procedimenti diversi da quelli descritti nel presente Manuale può provocare dei raggi laser pericolosi per la vita. Il cliente non deve assolutamente tentare di riparare egli stesso lo scanner laser. Non guardate mai nel raggio laser, anche se credete che lo scanner non sia attivo. Non aprite mai lo scanner per guardare dentro l’apparecchio. Se tuttavia lo fate, potete esporVi a dei raggi laser pericolosi per la vita. L’uso di apparecchi ottici con questo equipaggiamento laser aumenta il rischio di danni alla vista.

32

Page 37

APPENDIX F Patent Information “This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No.; 5,260,553; 5,340,971; 5,424,525; 5,484,992; 5,525,789; 5,528,024; 5,616,908; 5,627,359; 5,661,292; 5,777,315; 5,789,730; 5,789,731; 5,811,780; 5,828,048; 5,925,870; 6,029,894; 6,209,789; 6,227,450; 6,283,375; No license right or sublicense is granted, either expressly or by implication, estoppel, or otherwise, under any METROLOGIC or third party intellectual property rights (whether or not such third party rights are licensed to METROLOGIC), including any third party patent listed above, except for an implied license only for the normal intended use of the specific equipment, circuits, and devices represented by or contained in the METROLOGIC products that are physically transferred to the user, and only to the extent of METROLOGIC’S license rights and subject to any conditions, covenants and restrictions therein.” Other worldwide patents pending.

33

Page 38

INDEX

A

F

AC input/outlet...................2, 3, 4, 6 Accessories ...................................2 Approvals ........................ 13, 20, 30 Assignments pin ...................... 2, 4, 6, 7, 26, 27 Audible ..............................9, 11, 19 Autodiscriminates ........................19

Failure indicator(s) ............ 9, 11, 14 Failure modes ............................. 11

B Bar code ...1, 3, 8-10, 15, 16, 18, 19 Bar width .....................................12 Beep ......3, 4, 6, 8-11, 14-16, 19, 22

C Cable .....1-4, 6-8, 14, 17, 19, 26, 27 communication. 17, 18, 21, 26, 27 detachable ................... 1, 2, 7, 27 pin assignments .................26, 27 powerlink..............1-4, 6-8, 26, 27 Caution .......................... 4, 6, 13, 30 CDRH ..........................................20 CodeGate…………………….1,3,8 Communication ........4, 9, 10, 17-22 Compliance ................... 4, 6, 28, 30 Configuration . 1, 2, 9, 11, 14, 18, 26 Current .............................. 6, 14, 20 Customer service ....................2, 28

D DC transformer............................20 Decode capability ........................19 Default settings........................3, 21 Depth of field .................................1 Design specifications...................19 Disclaimer....................................28

E Electrical power supply...3-7, 14, 26

34

G Green LED ................ 3, 4, 8, 10, 19

H Host .......... 3, 4, 6, 7, 10, 14, 17, 26

I Indicators ...................... 8, 9, 10, 19 Input voltage ....................... 4, 6, 20 Installation....................... 2, 4, 6, 28 Interfaces .......................... 1, 19, 26

K Keyboard wedge . 1, 2, 6, 19, 26, 27

L Labels ......................................... 13 Light levels .................................. 20 Light pen ............... 1, 19, 21, 22, 26 Light source ................................ 19

M Maintenance ............................... 13

N Notices ........................................ 30

O Operating current ........................ 20 Operating temperture.................. 20 Output window .................. 8, 12, 13

Page 39

INDEX

P

Specifications.............................. 19

Parts ..........................................2, 8 Power supply............... 3, 4, 6, 7, 26 Programming modes ......... 3, 17, 18

T

Q Quick start .....................................3

R Razzberry tone ............ 9, 10, 11, 22 Red LED.................. 3, 4, 6, 8, 9, 10 Repair....................................11, 28 RMA ............................................28 RS-232 ............ 1, 17, 18, 19, 21, 26

S Scan lines....................................19 Scan speed .................................19 SELV .........................................4, 6 Service ..................................11, 28

Tones ...................................... 9, 19 Transformers............................... 20 Troubleshooting ........ 14, 15, 16, 17

U USB .................................... 1,28,30

V Ventilation ................................... 20 Visual .......................................... 10 Voltage........................................ 20

W Warranty ..................................... 28 Weight......................................... 19 Window ............................... 3, 8, 13

35

Page 40

June 2002

70 - 79001B