The text of a manual · part 5 of 5
IS6520/MS6520 Cubit Series Omnidirectional Bar Code Scanner Installation and User's Guide, pages 37 to 44
Pages 37 to 44 of 44
The original document is the PDF (880 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic IS6520
Page 37
APPENDIX D Warranty and Disclaimer Limited Warranty The IS6520/MS6520 Cubit® scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The IS6520/MS6520 Cubit® scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all IS6520/MS6520 Cubit® scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S. Federal, state and local laws, regulations and ordinances pertaining to their production and labeling. This warranty is limited to repair, replacement of Product or refund of Product price at the sole discretion of Metrologic. Faulty equipment must be returned to the Metrologic facility in Blackwood, New Jersey, U.S.A. or Puchheim, Germany. To do this, contact Metrologic’s Customer Service/Repair Department to obtain a Returned Material Authorization (RMA) number. In the event that it is determined the equipment failure is covered under this warranty, Metrologic shall, at its sole option, repair the Product or replace the Product with a functionally equivalent unit and return such repaired or replaced Product without charge for service or return freight, whether distributor, dealer/reseller, or retail consumer, or refund an amount equal to the original purchase price. This limited warranty does not extend to any Product which, in the sole judgement of Metrologic, has been subjected to abuse, misuse, neglect, improper installation, or accident, nor any damage due to use or misuse produced from integration of the Product into any mechanical, electrical or computer system. The warranty is void if the case of Product is opened by anyone other than Metrologic’s repair department or authorized repair centers. THIS LIMITED WARRANTY, EXCEPT AS TO TITLE, IS IN LIEU OF ALL OTHER WARRANTIES OR GUARANTEES, EITHER EXPRESS OR IMPLIED, AND SPECIFICALLY EXCLUDES, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE UNDER THE UNIFORM COMMERCIAL CODE, OR ARISING OUT OF CUSTOM OR CONDUCT. THE RIGHTS AND REMEDIES PROVIDED HEREIN ARE EXCLUSIVE AND IN LIEU OF ANY OTHER RIGHTS OR REMEDIES. IN NO EVENT SHALL METROLOGIC BE LIABLE FOR ANY INDIRECT OR CONSEQUENTIAL DAMAGES, INCIDENTAL DAMAGES, DAMAGES TO PERSON OR PROPERTY, OR EFFECT ON BUSINESS OR PROPERTY, OR OTHER DAMAGES OR EXPENSES DUE DIRECTLY OR INDIRECTLY TO THE PRODUCT, EXCEPT AS STATED IN THIS WARRANTY. IN NO EVENT SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO METROLOGIC FOR THE PRODUCT. METROLOGIC RESERVES THE RIGHT TO MAKE ANY CHANGES TO THE PRODUCT DESCRIBED HEREIN. Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012-4683 Customer Service Department: 1-800-ID-METRO (1-800-436-3876) TEL: 856-228-8100 FAX: 856-228-6673
Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b Munich, Germany TEL: 49-89-89019-0 FAX: 49-89-89019-200
31
Page 38
APPENDIX E Notices Notice This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Any unauthorized changes or modifications to this equipment could void the users authority to operate this device. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Notice This Class A digital apparatus complies with Canadian ICES-003.
Remarque Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Under no circumstances should the customer attempt to service the laser scanner. Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional. Never open the scanner in an attempt to look into the device. Doing so could result in hazardous laser light exposure. The use of optical instruments with the laser equipment will increase eye hazard.
Atención La modificación de los procedimientos, o la utilización de controles o ajustes distintos de los especificados aquí, pueden provocar una luz de láser peligrosa. Bajo ninguna circunstancia el usuario deberá realizar el mantenimiento del láser del escáner. Ni intentar mirar al haz del láser incluso cuando este no esté operativo. Tampoco deberá abrir el escáner para examinar el aparato. El hacerlo puede conllevar una exposición peligrosa a la luz de láser. El uso de instrumentos ópticos con el equipo láser puede incrementar el riesgo para la vista.
Attention L'emploi de commandes, réglages ou procédés autres que ceux décrits ici peut entraîner de graves irradiations. Le client ne doit en aucun cas essayer d'entretenir lui-même le scanner ou le laser. Ne regardez jamais directement le rayon laser, même si vous croyez que le scanner est inactif. N'ouvrez jamais le scanner pour regarder dans l'appareil. Ce faisant, vous vous exposez à une rayonnement laser qú êst hazardous. L'emploi d'appareils optiques avec cet équipement laser augmente le risque d'endommagement de la vision.
Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann eine gefährliche Laserstrahlung hervorrufen. Der Kunde sollte unter keinen Umständen versuchen, den Laser-Scanner selbst zu warten. Sehen Sie niemals in den Laserstrahl, selbst wenn Sie glauben, daß der Scanner nicht aktiv ist. Öffnen Sie niemals den Scanner, um in das Gerät hineinzusehen. Wenn Sie dies tun, können Sie sich einer gefährlichen Laserstrahlung aussetzen. Der Einsatz optischer Geräte mit dieser Laserausrüstung erhöht das Risiko einer Sehschädigung.
Attenzione L’utilizzo di sistemi di controllo, di regolazioni o di procedimenti diversi da quelli descritti nel presente Manuale può provocare delle esposizioni a raggi laser rischiose. Il cliente non deve assolutamente tentare di riparare egli stesso lo scanner laser. Non guardate mai il raggio laser, anche se credete che lo scanner non sia attivo. Non aprite mai lo scanner per guardare dentro l’apparecchio. Facendolo potete esporVi ad una esposizione laser rischiosa. L’uso di apparecchi ottici, equipaggiati con raggi laser, aumenta il rischio di danni alla vista.
32
Page 39
APPENDIX E (CONTINUED) European Standard
Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Funkstöreigenschaften nach EN 55022:1998 Warnung! Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funkstörungen verursachen; in diesem fall kann vom Betrieber verlangt werden, angemessene Maßnahmen durchführen.
Standard Europeo Attenzione Questo e’ un prodotto di classe A. Se usato in vicinanza di residenze private potrebbe causare interferenze radio che potrebbero richiedere all’utilizzatore opportune misure.
Attention Ce produit est de classe “A”. Dans un environnement domestique, ce produit peut être la cause d’interférences radio. Dans ce cas l’utiliseteur peut être amené à predre les mesures adéquates.
33
Page 40
APPENDIX F Patents “Patent Information This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No.; 4,960,985; 5,081,342; 5,216,232; 5,260,553; 5,340,971; 5,525,789; 5,557,093; 5,627,259; 5,637,852; 5,777,315; 5,789,731; 6,029,894; 4,360,798; 4,369,361; 4,387,297; 4,460,120; 4,496,831; 4,593,186; 4,607,156; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,923,281; 4,933,538; 4,992,717; 5,081,342; 5,015,833; 5,017,765; 5,059,779; 5,117,098; 5,124,539; 5,130,520; 5,132,525; 5,140,144; 5,149,950; 5,180,904; 5,200,599; 5,229,591; 5,247,162; 5,250,790; 5,250,791; 5,250,792; 5,262,628; 5,280,162; 5,280,164; 5,304,788; 5,321,246; 5,324,924; 5,396,053; 5,396,055; 5,408,081; 5,410,139; 5,436,440; 5,449,891; 5,468,949; 5,479,000; 5,532,469; 5,545,889; No license right or sublicense is granted, either expressly or by implication, estoppel, or otherwise, under any METROLOGIC or third party intellectual property rights (whether or not such third party rights are licensed to METROLOGIC), including any third party patent listed above, except for an implied license only for the normal intended use of the specific equipment, circuits, and devices represented by or contained in the METROLOGIC products that are physically transferred to the user, and only to the extent of METROLOGIC’S license rights and subject to any conditions, covenants and restrictions therein.” Other world wide patents pending.
34
Page 41
INDEX
A
F
AC input/outlet............. 2, 3, 4, 5, 29 Accessories ...................................2 Approvals ........................ 15, 32, 33 Assignments Pin ...........................................29 Audible ..........................................9 Autodiscriminates ........................23
Failure indicator(s) ........................ 9 Failure modes ......................... 9, 10
B Bar code1, 3, 9, 11, 12, 15, 16, 17, 18, 20, 21, 25 Bar width .....................................23 Beep ...... 3, 9, 10, 11, 19, 20, 21, 26
C Cable ............................. 2, 3, 22, 30 communication ..................29, 30 detachable................. 1, 6, 29, 30 pin assignments.................29, 30 powerlink ..................... 4, 5, 6, 30 Caution ................ 4, 5, 7, 15, 32, 33 CDRH ..........................................24 Ce................................................32 Communication ........... 4, 11, 22, 25 Compliance ...........................32, 33 Current .............................. 9, 19, 24 Customer service ....................2, 31
D DC transformer............................24 Decode capability ........................23 Default settings.......... 25, 26, 27, 28 Depth of field ....... 16, 17, 18, 23, 28 Design specifications...................23 Disclaimer....................................31
G Green LED ............................ 11, 19
H Host .............. 2, 4, 6, 11, 20, 22, 29
I Indicators .................... 9, 10, 11, 23 audible ...................................... 9 LED ............... 7, 9, 10, 11, 19, 20 Visual ...................................... 11 Input voltage ............................... 24 Installation............................. 4, 7, 8 Interfaces .............. 1, 19, 20, 21, 23
K Keyboard wedge ........... 1, 2, 29, 30
L Labels ......................................... 15 Light levels .................................. 24 Light pen ................... 25, 26, 27, 28 Light Pen......... 1, 23, 25, 26, 27, 28 Light source ................................ 23 List ................................................ 2
M Maintenance ............................... 15
E
N
Electrical......................................24
Notices .................................. 32, 33
35
Page 42
INDEX
O
S
Operating current ........................24 Operating temperture ..................24 Operation........................... 9, 23, 32 Operational..................................23 Output window...............................7
Scan lines ................................... 23 Scan pattern................................ 23 Scan speed ................................. 23 Service .............................. 2, 10, 31 Specifications........................ 23, 24 System interfaces ....................... 23
P Parts ..........................................2, 7 PC .................................................4 Port..........................................5, 22 Power supply ................... 1, 2, 5, 29 Powerlink ...........................2, 3, 4, 6 Programming guide .............3, 9, 12 Programming modes ....... 12, 13, 14
T Termination ............................. 5, 23 Tones ................................ 9, 10, 23 Transformers............................... 24 Troubleshooting ........ 19, 20, 21, 22
V
Quick start .....................................3
Ventilation ................................... 24 Visual .......................................... 11 Voltage........................................ 24
R
W
Razzberry tone ............ 9, 10, 11, 26 Red LED............................ 9, 11, 20 Repair..........................................10 RMA ............................................31 RS-232 .......... 22, 23, 25, 26, 27, 28
Warranty ............................... 19, 31 Weight......................................... 23 Window ................................... 7, 15
Q
36
Page 43
Page 44
August 2002 Printed in the USA