SECTION C
COMMUNICATIONS † Refer to Section P for full speed USB options.
Load USB Defaults †
³
9
9
9
9
7
8
Enable No Communication Mode
³
4
1
5
5
3
4
Select this option if the scanner does not interface with the host device.
Reserved
³
4
1
Reserved
5
5
6
4
³
Communications
C
3
9
1
7
5
0
0
Page 52
Page 53
SECTION D
CONFIGURATION MODE OPTIONS
Allow Configuration Mode on Power-Up
* Allow Configuration Mode Anytime
³
³
1
1
8
1
1
7
1
1
8
1
0
7
The scanner can only enter MetroSet® mode before any bar codes are scanned.
Allow MetroSet® configuration at any time.
Allow Configuration Codes on Power Up
* Allow Configuration Codes Anytime
³
³
1
1
8
1
1
6
1
1
8
1
0
6
Once a product bar code is scanned after power-up, the scanner will not accept configuration bar codes.
Allows scanning of configuration bar codes any time.
Enable Single Code Programming
Disable Single Code Programming
³
³
1
1
8
2
1
2
Scanner Operation
D
1
1
1
8
2
0
2
Page 54
Scanner Operation
D
2
SECTION D
SCAN BUFFERS
* 1 Scan Buffer
³
3
1
8
0
2 Scan Buffers
0
0
³
3
1
8
0
1
0
The scanner will scan one bar code in the scan field and not scan again until the bar code is removed from the scan field for the duration of the same symbol time out.
The scanner will scan 2 bar codes in the scan field one time each. These 2 bar codes will not be scanned again until they are removed from the scan field for the duration of the same symbol time out.
3 Scan Buffers
4 Scan Buffers
³
3
1
8
0
2
0
Same function as 2 Scan Buffers, but 3 bar codes are in the scan field.
³
3
1
8
0
3
0
Same function as 2 Scan Buffers, but 4 bar codes are in the scan field.
Page 55
SECTION D
SCAN BUFFERS
5 Scan Buffers
³
3
1
8
6 Scan Buffers
0
4
0
³
3
1
8
0
5
0
Same function as 2 Scan Buffers, but 5 bar codes are in the scan field.
Same function as 2 Scan Buffers, but 6 bar codes are in the scan field.
7 Scan Buffers
8 Scan Buffers
³
3
1
8
0
6
0
³
Same function as 2 Scan Buffers, but 7 bar codes are in the scan field.
3
1
8
0
7
0
Same function as 2 Scan Buffers, but 8 bar codes are in the scan field.
Scanner Operation
D
3
Page 56
Scanner Operation
D
4
SECTION D
REDUNDANT SCANS
* 0 Redundant Scans
1 Redundant Scans
³
3
0
1
1
0
0
³
3
0
1
1
1
0
Requires 1 good decode for a “good scan”.
Requires 2 consecutive decodes of the same bar code data for a “good scan”.
2 Redundant Scans
3 Redundant Scans
³
3
0
1
1
2
0
Requires 3 consecutive decodes of the same bar code data for a “good scan”.
³
3
0
1
1
3
0
Requires 4 consecutive decodes of the same bar code data for a “good scan”.
Page 57
SECTION D
REDUNDANT SCANS
4 Redundant Scans
5 Redundant Scans
³
3
0
1
1
4
0
³
3
0
1
1
5
0
Requires 5 consecutive decodes of the same bar code data for a “good scan”.
Requires 6 consecutive decodes of the same bar code data for a “good scan”.
6 Redundant Scans
7 Redundant Scans
³
3
0
1
1
6
0
³
Requires 7 consecutive decodes of the same bar code data for a “good scan”.
3
0
1
1
7
0
Requires 8 consecutive decodes of the same bar code data for a “good scan”.
Scanner Operation
D
5
Page 58
Scanner Operation
SECTION D
1
0
1
1
6
MISCELLANEOUS DECODE FEATURES
* Enable MAJIC
³
D
Disable MAJIC
1
3
³
1
0
1
1
0
3
The Metrologic Algorithm for Joining Incomplete Codes (MAJIC) aids in deciphering damaged or incomplete bar codes. Enable for more aggressive decoding.
Disable this feature when bar codes are in good reading condition. This will speed up decoding and improve over all accuracy.
Optional Same Symbol Check
* Normal Same Symbol Check
³
1
1
8
1
1
3
Requires 1 different character between successive bar codes to consider the bar code “new”.
³
1
1
8
1
0
3
Requires 3 different characters between successive bar codes to consider the bar code “new”.
Page 59
SECTION D
DEPTH OF FIELD ADJUSTMENTS
Do not change these settings unless instructed by a Metrologic representative. * Optimize for Low Density Codes †
Optimize for High Density Codes †
³
³
4
1
8
7
9
0
Fixed for High Density Codes †
³
4
1
8
7
0
4
1
8
7
0
³
4
1
8
7
† For use with omnidirectional scanners only. 4
1
8
7
2
3
Fixed for Medium Density Codes †
Fixed for Low Density Codes †
³
1
0
Scanner Operation
D
7
1
0
0
Page 60
Scanner Operation
SECTION D
D
8
SAME SYMBOL TIME OUTS
These numbers determine the length of time before a bar code can be rescanned after it is removed from the scan field. Single code fixed settings in msecs of No, 50, 100, 200, 500, 1200 (1.2 sec), 2000 (2.0 sec) and infinite are available. User configurable values can be set in user-configurable increments of 50 msecs to 6350 msecs (6.35 sec). No Same Symbol Time Out
Same Symbol Time Out 100 msecs
³
³
8
1
8
9
0
0
8
1
8
9
2
0
Same Symbol Time Out 200 msecs
* Same Symbol Time Out 500 msecs
³
³
8
1
8
9
4
0
8
1
8
9
1
0
0