Page 41
SECTION B
SUPPLEMENTS
Enable Bookland (978) Supplement Requirement
* Disable Bookland (978) Supplement Requirement
³
³
1
0
1
4
1
7
1
0
1
4
0
Enable 977 (2 digit) Supplemental Requirement
* Disable 977 (2 digit) Supplemental Requirement
³
³
1
0
1
3
1
4
1
0
1
3
0
7
4
The scanner will require a 2 digit supplement be scanned when an EAN-13 code begins with 977.
The scanner will not require a 2 digit supplement be scanned whenever an EAN-13 code begins with 977.
Enable 378/379 French Supplement Requirement
* Disable 378/379 French Supplemental Requirement
³
³
1
0
1
3
1
3
Supplements
B
3
1
0
1
3
0
3
Page 42
Supplements
B
4
SECTION B
SUPPLEMENTS
Enable 434/439 German Supplemental Requirement
* Disable 434/439 German Supplemental Requirement
³
³
1
0
1
4
1
5
1
0
1
4
0
5
Enable 414/419 German Supplemental Requirement
* Disable 414/419 German Supplemental Requirement
³
³
1
0
1
4
1
3
Enable # System 2 Requires Supplements
³
1
0
1
4
1
1
0
1
4
0
3
* Disable # System 2 Requires Supplements
2
³
1
0
1
4
0
2
Page 43
SECTION B
SUPPLEMENTS
Enable # System 5 Requires Supplements
³
1
0
1
2
1
* Disable # System 5 Requires Supplements
5
³
Enable Coupon Code 128
³
1
0
0
1
0
1
2
0
5
0
5
* Disable Coupon Code 128
3
1
5
³
1
0
0
3
Enable Code 128 ‘]C1’ Extended Code Format
* Disable Code 128 ‘]C1’ Extended Code Format
³
³
1
0
1
4
1
1
The scanner will transmit a ‘]C1’ at the beginning of the code 128 portion of the coupon code. Supplements
1
0
1
4
0
1
The scanner will not transmit a ‘]C1’ at the beginning of the code 128 portion of the coupon code. B
5
Page 44
Supplements
B
6
SECTION B
SUPPLEMENTS
Enable 128 Group Separators
³
1
0
1
4
* Disable 128 Group Separators
1
4
³
1
0
1
4
0
4
“GS” (1DH) character will be transmitted with coupon Code 128 codes.
“GS” (1DH) character will not be transmitted with coupon Code 128 codes.
* 100 msec to Find Supplemental
200 msec to Find Supplemental
³
3
0
1
3
1
0
The scanner will allot 100 milliseconds to “find” an add on after a main UPC/EAN bar code has been scanned.
³
3
0
1
3
2
0
The scanner will allot 200 milliseconds to “find” an add on after a main UPC/EAN bar code has been scanned.
Page 45
SECTION B
SUPPLEMENTS
400 msec to Find Supplemental
³
3
0
1
3
4
0
The scanner will allot 400 milliseconds to “find” an add on after a main UPC/EAN bar code has been scanned.
Enable Code ID’s with Supplements
³
1
0
1
2
1
* Disable Code ID’s with Supplements
4
Supplements
³
B
7
1
0
1
2
0
4
Page 46
Supplements
B
8
SECTION B
SUPPLEMENTS
* Beep Once on Supplements
³
1
1
8
4
Beep twice on Supplements
0
6
³
1
1
8
4
1
6
Enable ISBN Check Digit Transmission
Disable ISBN Check Digit Transmission
³
³
1
0
1
3
1
5
This feature is not available with all models.
1
0
1
3
0
5
Page 47
SECTION B
SUPPLEMENTS
Enable Bookland to ISBN Conversion
³
1
0
1
3
* Disable Bookland to ISBN Conversion
1
7
³
1
0
1
3
0
7
This feature is not available with all models.
Enable ISBN Re-Formatting
³
1
0
1
3
1
* Disable ISBN Re-Formatting
6
³
This feature is not available with all models. Supplements
B
9
1
0
1
3
0
6
Page 48
Supplements
B
10
SECTION B
SUPPLEMENTS
Enable Number System 4 Coupon Code 128
* Disable Number System 4 Coupon Code128
³
³
1
0
1
0
1
2
1
0
1
0
0
2
Supports Coupon Code 128 for Number System 4 bar codes.
Enable UPC Discard
³
1
0
1
0
1
* Disable UPC Discard
3
Supports UPC discard if the Code 128 portion of the Coupon Code 128 is scanned.
³
1
0
1
0
0
3
Page 49
SECTION C
COMMUNICATIONS
* Enable RS-232
Load Keyboard Wedge Defaults
³
4
1
5
5
5
4
³
9
9
9
9
9
4
The scanner will work with RS-232 ±12V serial output.
Scan this before selecting Normal or Stand Alone Mode.
Enable Light Pen/Wand Communication
Enable Keyboard Wedge Emulation
³
³
4
1
5
5
2
4
Enable Stand-Alone Keyboard Scanner
5
1
5
5
1
5
1
5
5
1
4
3
Select if the scanner provides keyboard emulation by converting the scanned bar code data to the PC keyboard scan code equivalent.
Use this option if a scanner is used in place of a light pen.
³
5
3
Allows the scanner to be used without an external keyboard. Communications
C
1
Page 50
Communications
C
2
SECTION C
COMMUNICATIONS
Load OCIA Defaults
Enable OCIA Output
³
9
9
9
9
9
3
³
4
1
5
5
4
4
Scan this before selecting Enable OCIA output.
Select this option if the communications requirement is an Optically Coupled Interface Adapter (OCIA). This is a docked (by the host) serial interface.
Load IBM 46xx Defaults
Enable IBM 46xx Communication
³
9
9
9
9
9
5
Scan this before selecting Enable IBM 46xx Communication
³
4
1
5
5
0
4
Select this option for IBM 46xx SIOC/RS485 communications. Not all scanners support this interface. The correct interface board is required.