NEED TO START OVER? Scan the Recall Default bar code. This will erase all previous settings and return to the scanner’s default communications protocol. • •
Keyboard Wedge interface scanners will load keyboard wedge defaults. All other scanners will load RS-232 defaults.
Metrologic manufactures custom OEM scanners, which load the OEM’s defaults. For further information on the affects they have on Metrologic default communications protocols refer to Section N, Custom Defaults.
Recall Defaults
³
Need to Start Over?
9
9 xi
9
9
9
8
Page 12
Page 13
SECTION A
UPC/EAN
* Enable UPC/EAN
³
1
0
0
1
1
Disable UPC/EAN
6
³
* Enable UPC-A
³
1
0
0
2
1
0
0
2
0
0
1
0
6
2
0
6
2
0
0
Disable UPC-A
1
6
³
* Enable UPC-E
³
1
1
0
0
Disable UPC-E
1
0
Code Types & Decode Rules
³
A
1
1
0
0
Page 14
Code Types & Decode Rules
A
2
SECTION A
UPC/EAN
* Enable EAN-13
³
1
0
0
2
Disable EAN-13
1
1
* Enable EAN-8
³
1
0
0
2
³
1
0
0
2
0
1
2
0
4
Disable EAN-8
1
4
³
1
0
0
* Enable Auto Redundancy UPC-E
Disable Auto Redundancy UPC-E
³
³
1
0
1
1
0
4
1
0
1
1
1
4
Page 15
SECTION A
CODE 128
* Enable Code 128
³
1
0
0
1
1
Disable Code 128
3
³
Enable UCC/EAN-28 ‘]C1’ Code Formatting
³
1
0
0
3
1
1
0
0
1
0
3
Disable UCC/EAN-128 ‘]C1’ Code Formatting
4
³
For Coupon Code 128, see Section B, page 5.
Code Types & Decode Rules
A
3
1
0
0
3
0
4
Page 16
Code Types & Decode Rules
A
4
SECTION A
CODE 39
* Enable Code 39
³
1
0
0
1
Disable Code 39
1
1
Enable MOD 43 Check on Code 39
³
1
0
0
2
³
1
0
0
1
0
1
* Disable MOD 43 Check on Code 39
1
3
³
1
0
0
2
0
3
The scanner will only scan Code 39 bar codes that have a valid Modulo 43 check digit.
The scanner will not test Code 39 bar codes for a modulo 43 check digit.
Transmit Mode 43 Check Digit on Code 39
* Do Not Transmit Mode 43 Check Digit on Code 39
³
³
1
0
7
7
1
5
This feature works in conjunction with Mode 43 Check on Code 39. Both options must be enabled for this feature to work.
1
0
7
7
0
5
This option will not transmit Code 39’s Mod 43 check character.
Page 17
SECTION A
CODE 39
Enable Full ASCII Code 39
* Disable Full ASCII Code 39
³
³
1
0
0
2
1
7
Enable PARAF Support
1
0
0
2
1
0
0
2
0
7
* Disable PARAF Support
(Italian Pharmaceutical Codes)
³
1
5
³
1
0
0
2
0
5
The scanner will convert Code 39 bar codes to PARAF format.
The scanner will not convert code 39 bar codes to PARAF format.
Enable TRI-OPTIC Code
* Disable TRI-OPTIC Code
³
³
1
0
0
3
1
2
Code Types & Decode Rules
A
5
1
0
0
3
0
2
Page 18
Code Types & Decode Rules
SECTION A
1
0
0
1
1
Disable Interleaved 2 of 5 (ITF)
5
Enable MOD 10 Check on ITF
³
1
0
0
3
6
INTERLEAVED 2 OF 5
* Enable Interleaved 2 of 5 (ITF)
³
A
³
1
0
0
1
0
5
0
0
* Disable MOD 10 Check on ITF
1
0
³
1
0
0
3
The scanner will only scan Interleaved 2 of 5 (ITF) Bar codes that have a Modulo 10 check digit.
The scanner will not test Interleaved 2 of 5 (ITF) bar codes for a Modulo 10 check digit.
Transmit MOD 10 Check Digit on ITF
* Do Not Transmit MOD 10 Check Digit on ITF
³
1
0
7
7
1
4
The scanner transmits Interleaved 2 of 5 (ITF) MOD 10 check character.
³
1
0
7
7
0
4
The scanner will not transmit Interleaved 2 of 5 (ITF) MOD 10 check digit characters. This feature works in conjunction with Mod 10 Check on ITF. Both must be enabled for this feature to work.
Page 19
SECTION A
INTERLEAVED 2 OF 5
Enable ALT Check Digit ITF
³
1
0
0
* Disable ALT Check Digit ITF
7
1
7
³
Enable 12 Digit ITF Check Digit at 1
³
1
0
0
9
1
0
0
7
0
7
* Normal Check Digit
1
0
³
1
0
0
9
0
0
This feature requires MOD 10 ITF Check Digit to be enabled. The 12character ITF check digit calculation will start with 1 instead of 0. Enable ITF/Code 39 Filter
* Disable ITF/Code 39 Filter
³
³
1
0
0
4
1
6
Supports Code 39/ITF filters. This feature may adversely affect reading of Codabar, Code 93 and some other non-standard symbologies. Code Types & Decode Rules
A
7
1
0
0
4
0
6
Page 20
Code Types & Decode Rules
SECTION A
9
0
1
6
8
INTERLEAVED 2 OF 5
~ ITF Symbol Length Lock 1 †
³
A
0
~ ITF Symbol Length Lock 2 †
0
To specify a 1st ITF symbol length lock, scan the above bar code and the appropriate code bytes located in Section M. †
³
9
0
1
7
0
0
To specify a 2nd ITF symbol length lock, scan the above bar code and the appropriate code bytes located in Section M. †
~ ITF Minimum Symbol Length † † Refer to the Multi-Code Configuration Method on page x.
³
9
0
3
4
0
0
To specify a minimum number of ITF characters to be decoded, scan the above bar code and the appropriate code bytes located in Section M.†