Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 19

MetroSelect Configuration Guide, pages 1 to 10

Pages 1 to 10 of 188

The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Metrologic MK9520 / MS9520, Metrologic MS9535, Metrologic MS9590, Metrologic IS6520 and Metrologic MS5145

Page 1 read from a scan by OCR; it may hold reading errors

@ Metrologic’

METROLOGIC INSTRUMENTS, INC.

MetroSelect®

Configuration Guide

Page 2

LOCATIONS CORPORATE HEADQUARTERS North America

Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012-4683

Customer Service: 1-800-ID-METRO Tel: 856-228-8100 Fax: 856-228-6673 Email: info@metrologic.com Internet: www.metrologic.com

EUROPEAN HEADQUARTERS Germany, Middle East and Africa

Metrologic Instruments GmbH Dornierstrasse 2 82178 Puchheim b. Munich, Germany

Tel: +49 89 89019 0 Fax: +49 89 89019 200 Email: info@europe.metrologic.com Germany Email: info@de.metrologic.com

Spain

Metrologic Eria lbérica SL Julián Camarillo 29, D-1 Edificio Diapasón 28037 Madrid

Tel: +34 913 272 400 Fax: +34 913 273 829 Email: info@es.metrologic.com

Italy

Metrologic Instruments Italia srl Via Emilia 70 40064 Ozzano dell’Emilia (BO)

Tel: +39 0 51 6511978 Fax: +39 0 51 6521337 Email: info@it.metrologic.com

France

Metrologic Eria France SA 69 Rue de la Belle Etoile ZI Paris Nord II, BP 50057 95947 – ROISSY CDG CEDEX

Tel: +33 (0) 1 48.63.78.78 Fax: +33 (0) 1 48.63.24.94 Email: info@fr.metrologic.com

United Kingdom

Metrologic Instruments UK Limited 58 Tempus Business Centre Kingsclere Road, Basingstoke Hampshire RG21 6XG

Tel: +44 (0) 1256 365900 Fax: +44 (0) 1256 365955 Email: info@uk.metrologic.com

Singapore

Metrologic Asia (Pte) Ltd No. 8 Kaki Bukit Place 4th Floor Singapore 416186

Tel: 65-6842-7155 Fax: 65-6842-7166 Email: info@sg.metrologic.com

China

Metro (Suzhou) Technologies Co., Ltd. 221 Xing Hai Street Suzhou Industrial Park Suzhou, China 215021

Tel: 86-512-62572511 Fax: 86-512-62571517 Email: info@cn.metrologic.com

Japan

Metrologic Japan Co., Ltd. Matsunoya Building, 6 Floor 3-14-8 Higashiueno Taitou-Ku, Tokyo 110-0015 Japan

Tel: 81-03-3839-8511 Fax: 81-03-3839-8519 Email: info@jp.metrologic.com

Brazil

Metrologic do Brasil Ltda. Rua da Paz 2059 CEP 04713-002 Chácara Santo Antônio São Paulo, SP, Brasil

Tel: 55-11-5182-8226 Fax: 55-11-5182-8315 Email: info@br.metrologic.com

Outside Brazil

Metrologic South America Rua da Paz 2059 CEP 04713-002 Chácara Santo Antônio São Paulo, SP, Brasil

Tel: 55-11-5182-7273 Fax: 55-11-5182-7198 Email: info@sa.metrologic.com

ASIA

SOUTH AMERICA

Copyright © 2002 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Products and brand names mentioned in this document are trademarks of their respective companies.

Page 3

TABLE OF CONTENTS Introduction Symbol Key ................................................................................................. ix

Bar Code Configuration Methods Single-Code Method..................................................................................... x Multi-Code Method ....................................................................................... x

Need to Start Over? Recall Defaults ............................................................................................ xi

Section A: Code Types and Decode Rules UPC/EAN......................................................................................................1 Code 128 ......................................................................................................3 Code 39 ........................................................................................................4 Interleaved 2 of 5..........................................................................................6 Standard 2 of 5 .............................................................................................9 Other 2 of 5 Codes .....................................................................................10 Codabar......................................................................................................12 Code 93 ......................................................................................................13 Code 11 ......................................................................................................13 Telepen.......................................................................................................14 Plessey Codes............................................................................................15 Other Decode Features..............................................................................17 Configurable Code Lengths........................................................................18 RSS 14 Features........................................................................................21 RSS Limited Features ................................................................................23 RSS Expanded Features............................................................................25

Section B: Supplements Two Digit Supplements/Redundancy ...........................................................1 Five Digit Supplements/Redundancy ...........................................................1 Supplements Required/Not Required...........................................................2 Remote Supplemental Requirement ............................................................2 Bookland (978) Supplement Required .........................................................3

Table of Contents iii

Page 4

Table of Contents iv

TABLE OF CONTENTS Section B: Supplements (Continued) 977 (2 Digit) Supplement Required ..............................................................3 378/379 French Supplement Requirement...................................................3 434/439 German Supplement Required.......................................................4 414/419 German Supplement Required.......................................................4 # System 2 Requires Supplements ..............................................................4 # System 5 Requires Supplements ..............................................................5 Coupon Code 128 ........................................................................................5 Code 128 ‘]C1’ Extended Code Format........................................................5 Code 128 Group Separators ........................................................................6 100 msec to Find Supplemental ...................................................................6 200 msec to Find Supplemental ...................................................................6 400 msec to Find Supplemental ...................................................................7 Code ID’s with Supplements ........................................................................7 Beep Once/Twice on Supplements ..............................................................8 ISBN Check Digit Transmission ...................................................................8 Bookland to ISBN Conversion ......................................................................9 ISBN Re-Formatting .....................................................................................9 Number System 4 Coupon Code 128.........................................................10 UPC Discard...............................................................................................10

Section C: Communications Enable RS-232 .............................................................................................1 Load Keyboard Wedge Defaults...................................................................1 Enable Light Pen/Wand Communication......................................................1 Enable Keyboard Wedge Emulation.............................................................1 Enable Stand-Alone Keyboard Scanner.......................................................1 Load OCIA Defaults......................................................................................2 Enable OCIA Output.....................................................................................2 Load IBM 46xx Defaults ...............................................................................2 Enable IBM 46xx Communication ................................................................2 Load USB Defaults .......................................................................................3 Enable No Communication Mode.................................................................3 Reserved ......................................................................................................3

Page 5

TABLE OF CONTENTS Section D: Scanner Operation Configuration Mode Options.........................................................................1 Scan Buffers .................................................................................................2 Redundant Scans .........................................................................................4 Miscellaneous Decode Features ..................................................................6 Depth of Field Adjustments ..........................................................................7 Same Symbol Time Outs..............................................................................8 LED Options ...............................................................................................10 Beeper Options...........................................................................................11 Inter-Character Data Transmission Delays ................................................15 Inter-Record Data Transmission Delays.....................................................16 Communication Time Out Options .............................................................17 Host Scanner Commands ..........................................................................19 Power Save Modes ....................................................................................24 Japanese Double Field Support .................................................................28 Test Modes.................................................................................................33

Section E: Prefixes/Suffixes Configurable Prefixes, All Data.....................................................................1 Configurable ID Characters, Code Specific..................................................3 Identifiers Character ...........................................................................3 Standard Prefix Characters ..........................................................................8 Standard Suffix Characters ........................................................................13 Longitudinal Redundancy Check (LRC) .....................................................15 Configurable Suffixes, All Data...................................................................16 Special Formats..........................................................................................19 Character Replacements............................................................................20

Section F: Code Formatting UPC/EAN......................................................................................................1 Codabar........................................................................................................5 Code 39 ........................................................................................................7 Code 11 ........................................................................................................9

Table of Contents v

Page 6

Table of Contents vi

TABLE OF CONTENTS Section F: Code Formatting (Continued) Telepen.........................................................................................................9 Plessey .......................................................................................................10 2 of 5...........................................................................................................12

Section G: RS-232 Enable RS-232 Mode ...................................................................................1 Parity Features .............................................................................................2 Baud Rates...................................................................................................3 Data/Stop Bits...............................................................................................5 Hardware Handshaking ................................................................................6 Software Handshaking .................................................................................9 Miscellaneous.............................................................................................12

Section H: Keyboard Enable Keyboard Emulation .........................................................................1 Country/Scan Code Table Selects ...............................................................2 Keyboard/System Type ................................................................................4 Special Keyboard Features ..........................................................................5 Inter-Scan Code Delays ...............................................................................9 Control Sets................................................................................................10 3151 Terminal Keyboard ............................................................................12

Section I: OCIA Load OCIA Defaults......................................................................................1 Enable OCIA.................................................................................................1 DTS/Siemens ...............................................................................................1 DTS/Nixdorf ..................................................................................................1 NCR-S ..........................................................................................................1 NCR-F ..........................................................................................................1

Section J: Light Pen/Laser Emulation Enable Light Pen Mode ................................................................................1 Space/Bar Height .........................................................................................1 Transmit Code 39 .........................................................................................1

Page 7

TABLE OF CONTENTS Section J: Light Pen/Laser Emulation (Continued) Transmit as Scanned....................................................................................1 Poll Light Pen Source ...................................................................................2 Light Pen Extra Toggle .................................................................................2 10x Narrow Element Border .........................................................................2 50x Narrow Element Border .........................................................................2 Set Narrow Element Width ...........................................................................3 Laser Emulation............................................................................................3

Section K: IBM 46xx Configuration Enable IBM 46xx Communication ................................................................1 Load IBM 46xx Defaults ...............................................................................1 IBM Ports......................................................................................................1 IBM Reserve Codes .....................................................................................2

Section M: Code Bytes Code Byte Usage .........................................................................................1 Code Bytes 0-5.............................................................................................2 Code Bytes 6-9.............................................................................................3 Reserved Codes...........................................................................................4 Code Byte/Code Type Table ........................................................................5 ASCII Reference Table.................................................................................6 Extended Key Code Reference Table ........................................................11

Section N: Miscellaneous Features Custom Defaults ...........................................................................................1 Serial Program Mode....................................................................................3

Section O: Auxiliary Port Controls Disable AUX Port..........................................................................................1 AUX Port and Secondary Device Data Formats For the MS7220, MS7320, and MS7600 ......................................................1 When Using a Metrologic Device as a Secondary..............................1 When Using a non-Metrologic RS-232 Device as a Secondary .........3

Table of Contents vii

Page 8

Table of Contents viii

TABLE OF CONTENTS Section O: Auxiliary Port Controls (Continued) Additional AUX Port Data Formats ...............................................................4 AUX Port Baud Rates...................................................................................6 AUX Port Parity ............................................................................................8 AUX Port Stop/Data Bits...............................................................................9 Enable/Disable RTS/CTS Handshaking .....................................................10 Message AUX RTS/CTS ............................................................................10 Character AUX RTS/CTS ...........................................................................10 Enable/Disable D/E Commands .................................................................10 Enable/Disable F/L Commands..................................................................11 Enable/Disable M/O Commands ................................................................11 Enable/Disable XON/XOFF ........................................................................11 Enable/Disable ACK/NAK...........................................................................12 AUX CTS/RTS Polarity...............................................................................12 Main Output Port Auxiliary Data Formats ...................................................13 Inter-Character Delays ...............................................................................15

Section P: USB Full Speed USB ............................................................................................1

Page 9

INTRODUCTION Your new scanner has been configured at the factory with a set of default communication protocols. Since many host systems have unique formats and protocol requirements, Metrologic provides a wide range of configurable features that may be selected with the use of this bar code configuration guide. Once the configuration is completed, the scanner stores the settings in nonvolatile memory or NOVRAM. NOVRAM saves the settings when the power is turned off.

Symbol Key

* (asterisk)

Default Feature

~ (tilde)

Feature requires the Multi-Code Configuration Method, see Bar Code Configuration Methods on page x. Important!

Note

Introduction ix

Page 10

Bar Code Configuration Methods x

BAR CODE CONFIGURATION METHODS Metrologic scanners can be bar code configured in two ways: the Single-Code Method and the Multi-Code Method. Single-Code Method Most features can be enabled or disabled using the Single-Code Method. 1.

Power up the scanner.

2.

Scan the bar code(s) for the desired feature(s).

3.

Observe a multi-toned, “save setting” beep that indicates the configuration has been saved to NOVRAM.

Multi-Code Method All features can be enabled or disabled using the Multi-Code Method. A feature marked with a “~” requires the Multi-Code Method. 1.

Power up the scanner.

2.

Scan the Enter/Exit Configuration Mode bar code. [3 beeps]

3.

Scan the bar code(s) for the desired feature(s). [1 beep]

4.

Scan the Enter/Exit Configuration Mode bar code [3 beeps] and save new configuration. Enter/Exit Configuration Mode

³

9

9

9

9

9

9

To abort a configuration change, power off the scanner before scanning the Enter/Exit Configuration Mode bar code.