Page 131

SECTION H

ENABLE KEYBOARD EMULATION

Load Keyboard Wedge Defaults

³

9

9

9

9

9

4

Loads default settings for keyboard wedge mode.

Enable Stand-Alone Keyboard Emulation

* Enable Keyboard Wedge Emulation

³

³

5

1

5

5

1

5

3

Use this with special standalone models that are not cabled for an external keyboard. When the StandAlone Mode is enabled, the scanner will send keyboard “power on” information and configure hardware to simulate a constant keyboard connection.

Keyboard

5

1

5

5

1

4

3

Use this with an external keyboard. Transmit in wedge mode to allow standard PC keyboards to communicate when no bar code data is available.

H

1

Page 132

Keyboard

SECTION H

4

1

6

2

2

COUNTRY/SCAN CODE TABLE SELECTS

* USA Keyboard

³

H

Switzerland Keyboard

6

0

³

4

1

6

2

8

0

Enable USA Keyboard.

Enable Swiss Keyboard

Spain Keyboard

Italy Keyboard

³

4

1

6

2

5

0

³

4

1

6

2

4

0

Enable Spanish Keyboard

Enable Italian Keyboard

Germany Keyboard

France Keyboard

³

4

1

6

2

3

0

Enable German Keyboard

³

4

1

6

2

2

0

Enable French Keyboard

Page 133

SECTION H

COUNTRY/SCAN CODE TABLE SELECTS

UK Keyboard

³

4

1

6

Belgium Keyboard

2

1

0

³

4

1

6

2

0

0

Enable UK Keyboard.

Enable Belgium Keyboard

Japanese Keyboard

IBM 4700 Financial Keyboard

³

4

1

6

2

1

0

0

³

Enable Japanese Keyboard

4

1

6

2

9

0

Enable Sweden/Finland Keyboard

Keyboard

1

6

2

7

0

Enable IBM 4700 Financial Keyboard

Sweden/Finland Keyboard

³

4

H

3

Page 134

Keyboard

SECTION H

2

1

6

4

KEYBOARD/SYSTEM TYPE

* AT Keyboard

³

H

XT Keyboard

2

1

5

³

2

1

6

2

0

5

If using an AT computer, scan the above bar code. (Includes IBM PS/2 and compatible models 50, 55, 60, 80)

If using an XT computer, scan the above bar code.

PS/2 Keyboard

Terminal KB Emulation

³

2

1

6

2

2

5

Scan the above code for PS/2 computer. (Includes IBM PC and compatible models 30, 70 and 8556)

³

2

1

6

2

3

5

Scan the above code to enable terminal keyboard emulation mode.

Page 135

SECTION H

SPECIAL KEYBOARD FEATURES

Transmit Make Code Only

³

1

1

6

3

* Transmit Make/Break Code

1

1

³

Do not scan unless instructed by a Metrologic representative.

1

1

6

3

1

6

3

0

1

Do not scan unless instructed by a Metrologic representative.

Do Not Transmit F0H Break Code

³

1

* Transmit F0H Break Code

0

0

³

1

1

6

3

1

0

The scanner will not transmit the F0H in the break-code sequence.

The scanner will transmit the F0H in the break-code sequence.

Transmit Cleanup Bit

* Do Not Transmit Cleanup Bit

³

1

1

6

3

1

5

³

Use for certain NEC computers.

Keyboard

H

5

1

1

6

3

0

5

Page 136

Keyboard

SECTION H

1

1

6

2

6

SPECIAL KEYBOARD FEATURES

Enable Alt Mode

³

H

* Disable Alt Mode

1

7

³

The scanner will duplicate the following keyboard sequence: Hold down ALT key and Type decimal number that corresponds to the appropriate character.

1

1

6

2

0

Caution: If the host software application uses the right ALT key as a “Hot” key, ALT mode must be disabled.

Enable Auto Detect Mode (AT/PS2)

* Disable Auto Detect Mode (AT/PS2)

³

³

1

1

6

2

1

4

Automatically detects caps lock status.

7

1

1

6

2

0

4

The Auto Detect Caps Lock feature is not supported.

Page 137

SECTION H

SPECIAL KEYBOARD FEATURES

Enable Caps Lock (XT)

* Disable Caps Lock (XT)

³

³

1

1

6

2

1

4

1

1

6

2

0

4

The Caps Lock feature is not supported.

Send Numbers as Keypad Data

* Send Numbers as Normal Data

³

³

1

1

6

3

1

6

1

1

6

3

0

6

All data is sent as if it has been entered on a keypad.

Enable Reserved Feature

³

1

1

6

4

* Disable Reserved Feature

1

0

Keyboard

³

H

7

1

1

6

4

0

0

Page 138

Keyboard

SECTION H

H

8

SPECIAL KEYBOARD FEATURES

* Use Extended ASCII to Send Extended Key Codes

Use Extended ASCII Characters as Extended ASCII

³

³

1

1

6

3

0

3

1

1

6

3

1

3

Use extended ASCII characters to send PC keyboard keys such as F1, F2, etc…See section M for details.

Transmit extended ASCII codes via ALT mode.

* Character KB Inhibit

Message KB Inhibit

³

1

1

6

3

0

4

³

1

1

6

3

1

4

Page 139

SECTION H

INTER-SCAN CODE DELAYS

Inter-Scan Code Delay 800 Microseconds

³

8

1

6

5

8

Inter-Scan Code Delay 7.5 msec

0

³

8

1

6

5

7

5

0

The time specified represents the amount of time between individual 9 bit-scan codes.

The time specified represents the amount of time between individual 9 bit-scan codes.

This parameter may need to be adjusted for operation with certain PC keyboard BIOS.

This parameter may need to be adjusted for operation with certain PC keyboard BIOS.

Inter-Scan Code Delay 15 msec

~ Variable Inter-Scan Code Delay msec

³

³

8 1 6 5 1 5 0 0

The time specified represents the amount of time between individual 9 bit-scan codes.

1

6

5

0

0

Refer to the Multi-Code Configuration method on page x.

This parameter may need to be adjusted for operation with certain PC keyboard BIOS.

Keyboard

9

H

9

Page 140

Keyboard

H

10

SECTION H

CONTROL SETS

In general, standard bar code symbologies will only encode the ASCII character set. Function keys, arrow keys and many other “extended” keys on an IBM compatible keyboard do not translate to ASCII characters. One method of “bar coding” the extended keys is to substitute the extended key codes when a specific ASCII control character found in the bar code stream. The Control Sets are specific translation of the ASCII (HEX) set.

CONTROL SET #1 Enable Control Set #1

³

4

1

6

4

8

4

Disable Control Set #1

³

4

1

6

4

0

4