Page 121
SECTION G
BAUD RATES
A “Baud” or “Baud Rate” is the speed at which data is transmitted. Select a Baud for the scanner that matches the host device.
115200 BAUD Rate
³
57600 BAUD Rate
³
4
1
5
8
4
1
5
8
1
5
8
1
0
8
0
6
0
38400 BAUD Rate
9
0
19200 BAUD Rate
³
4
³
4
1
5
8
14400 BAUD Rate
7
0
³
RS-232
4
1
5
8
G
3
0
Page 122
RS-232
SECTION G
BAUD RATES
* 9600 BAUD Rate
³
4
1
5
8
5
4800 BAUD Rate
0
2400 BAUD Rate
³
4
1
5
8
4
1
5
8
³
4
1
5
8
4
0
2
0
0
0
1200 BAUD Rate
3
0
600 BAUD Rate
³
4
G
³
4
1
5
8
300 BAUD Rate
1
0
³
4
1
5
8
Page 123
SECTION G
DATA/STOP BITS
* 7 Data Bits
³
1
1
6
8 Data Bits
0
0
3
³
1
1
6
0
1
3
0
0
4
Number of data bits transmitted for each character.
1 Stop Bit
³
1
1
* 2 Stop Bits
6
0
1
4
³
RS-232
1
1
6
G
5
Page 124
RS-232
SECTION G
HARDWARE HANDSHAKING
Enable RTS/CTS Handshaking
³
1
1
5
8
6
G
* Disable RTS/CTS Handshaking
1
6
³
1
1
5
8
0
Output a Request to Send (RTS) signal and wait for a Clear To Send (CTS) signal before transmitting data.
Do not use RTS/CTS handshaking.
* Character RTS/CTS
Message RTS/CTS
³
1
1
5
8
1
5
³
1
1
5
8
0
6
5
Activate/Deactivate RTS signal for each character.
Activate RTS before sending the first character and leave it active until after the last character has been transmitted.
Invert RTS Polarity (RSV1)
* Standard RTS Polarity
³
³
1
2
4
+12V = Inactive -12V = Active
5
1
0
1
2
4
5
0
0
Use standard RTS polarity -12V = Inactive +12V = Active
Page 125
SECTION G
HARDWARE HANDSHAKING
Invert CTS Polarity (RSV2)
* Standard CTS Polarity
³
³
1
2
4
5
1
1
+12V = Inactive, do not send
1
2
4
5
0
1
-12V = Inactive, do not send +12V = Active, OK to send
-12V = Active, OK to send
Activate RTS, Do Not wait for CTS (RSV3)
* Activate RTS, Wait for CTS
³
³
1
2
4
5
1
2
1
2
4
5
0
2
Activate RTS for transmission but do not wait for CTS to send.
Wait for CTS after activating RTS.
Test CTS Not Present Before RTS (RSV4)
* Do Not Test for CTS Present Before RTS
³
1
2
4
5
1
3
³
Do not activate RTS if CTS is already present.
1
2
4
5
0
3
Activate RTS without testing if CTS is already active.
RS-232
G
7
Page 126
RS-232
SECTION G
HARDWARE HANDSHAKING
Enable DTR Support
³
1
1
5
8
8
G
1
* Disable DTR Support
7
³
1
1
5
8
0
7
The scanner will stop scanning when the Data Terminal Ready (DTR) signal goes inactive.
Enable RTS Counter Toggle
³
1
1
5
9
1
* Disable RTS Counter Toggle
5
The scanner will toggle the RTS line on a good decode.
³
1
1
5
9
0
5
Page 127
SECTION G
SOFTWARE HANDSHAKING
Enable XON/XOFF Handshaking
³
1
1
5
9
* Disable XON/XOFF Handshaking
1
4
³
1
1
5
9
0
4
The scanner will stop transmission whenever an XOFF (ASCII 13H) is received. Transmission will resume after an XON (ASCII 11H) is received.
The scanner will not test for XON/XOFF.
Enable ACK/NAK
* Disable ACK/NAK
³
1
1
5
9
1
3
³
After transmitting data, wait for an ACK (06H) or a NAK (15H) response from the host.
1
1
5
9
0
3
Do not support ACK/NAK handshaking.
If ACK is received, complete the communications cycle and look for more bar codes. If NAK is received, retransmit the last set of bar code data and wait for ACK/NAK again.
RS-232
G
9
Page 128
RS-232
SECTION G
10
G
SOFTWARE HANDSHAKING
Enable O/N Handshaking
Disable O/N Handshaking
³
³
1
1
5
9
1
2
1
1
5
9
0
2
ACK/NAK handshaking (page G 9) must be enabled for this feature to work. Support BEL/CAN in ACK/NAK
³
1
1
5
9
1
* Ignore BEL/CAN in ACK/NAK
1
³
1
1
5
9
0
1
When BEL (07H) is received, the scanner beeps 3 times and exits the communications loop. If a CAN (18H) is received, then the scanner will exit the communications loop, silently.
Ignore BEL/CAN characters in communication loop.
Enable Razz Command
Disable Razz Command
³
³
1
1
8
4
1
5
When a z is received, the scanner will RAZZ once. Multiple razzes can be sounded if the character before the z is a number and is sent within 1 second of the z. The normal BEL commands must be activated for feature.
1
1
8
4
0
Ignore z characters in communication loop.
5
Page 129
SECTION G
SOFTWARE HANDSHAKING
Enable 5 Retries on ACK/NAK Time Out
³
1
1
8
0
1
* Disable 5 Retries on ACK/NAK Time Out
3
³
Allow up to 5 NAK retransmissions of the data before dropping out of the communications loop.
1
1
8
0
0
3
Do not limit retransmission to 5 NAK cycles.
RS-232
G
11
Page 130
RS-232
12
G
SECTION G
MISCELLANEOUS
Enable French PC Term
* Disable French PC Term
³
³
1
1
6
1
1
0
1
1
6
1
0
0
The scanner transmits PC type make/break scan codes instead of ASCII data characters. The scan codes match a WYSE French PC Terminal Emulation.
Do not transmit in French PC Term Mode.
Enable USA Wyse PC
Disable USA Wyse PC
³
1
1
6
1
1
7
Enables USA Wyse PC style keyboard PCTERM mode.
³
1
1
6
1
0
7
Disables USA Wyse PC style keyboard PCTERM mode.