Page 101
SECTION E
LONGITUDINAL REDUNDANCY CHECK (LRC)
Enable Transmit of LRC Calculation
³
1
0
7
8
* Disable Transmit of LCR Calculation
1
1
³
1
0
7
8
0
1
The scanner outputs an LRC check character after the bar code.
The scanner will not output an LRC (check character) after the bar code.
* Start LRC on First Byte
Start LRC on Second Byte
³
³
1
0
7
8
0
0
The scanner will calculate the LRC check digit starting with the first character.
1
0
7
8
1
0
The scanner will calculate the LRC check digit starting with the second character.
Prefixes/Suffixes
E
15
Page 102
Prefixes/Suffixes
SECTION E
16
E
CONFIGURABLE SUFFIXES, ALL DATA
Scan the Enter/Exit Configuration Mode bar code before trying to set this feature. Refer to the Multi-Code Method on page x. Enter/Exit Configuration Mode
³
9
9
9
9
9
~ Configurable Suffix Character #1
9
³
9
0
4
5
0
0
A suffix ID can be added and assigned for data transmission. Use this code with a 3 code byte sequence from Section M that represents the desired character.
~ Configurable Suffix Character #2
³
9
0
4
6
0
~ Configurable Suffix Character #3
0
Assigns a 2nd configurable suffix character.
³
9
0
4
7
0
0
Assigns a 3rd configurable suffix character.
Page 103
SECTION E
CONFIGURABLE SUFFIXES, ALL DATA
~ Configurable Suffix Character #4 †
³
9
0
4
8
0
~ Configurable Suffix Character #5 †
0
³
Assigns a 4th configurable suffix character.
9
0
4
9
0
0
Assigns a 5th configurable suffix character.
† While using the Multi-Code method, scan this bar code followed by the 3 code byte bar codes in Section M that represents the desired character. (Refer to the Multi-Code method on page x.)
~ Configurable Suffix Character #6 †
³
9
0
5
0
0
~ Configurable Suffix Character #7 †
0
³
Assigns a 6th configurable suffix character.
9
0
5
1
0
0
Assigns 7th configurable suffix character. Prefixes/Suffixes
E
17
Page 104
Prefixes/Suffixes
SECTION E
CONFIGURABLE SUFFIXES, ALL DATA
~ Configurable Suffix Character #8 †
³
9
0
5
2
18
E
0
~ Configurable Suffix Character #9 †
0
³
9
0
5
3
0
0
Assigns a 8th configurable suffix character.
Assigns a 9th configurable suffix character.
~ Configurable Suffix Character #10 †
† While using the MultiCode method, scan this bar code followed by the 3 code byte bar codes in Section M that represent the desired character. (Refer to the Multi-Code method on page x.)
³
9
0
5
4
0
0
Assigns a 10th configurable suffix character.
* Clear All User Configurable Suffixes
³
9
9
9
9
8
4
Page 105
SECTION E
SPECIAL FORMATS
Enable SINEKO Mode
* Disable SINEKO Mode
³
1
0
7
9
1
4
³
Enable Newcode Formatting Mode A
³
1
1
6
7
1
1
6
7
0
7
9
0
4
* Disable Newcode Formatting Mode A
1
1
³
Enable Newcode Formatting Mode B
³
1
1
1
6
7
0
1
* Disable Newcode Formatting Mode B
1
0
³
Prefixes/Suffixes
1
E
1
19
6
7
0
0
Page 106
Prefixes/Suffixes
SECTION E
E
20
CHARACTER REPLACEMENTS
To replace a character: 1. Scan the Enter/Exit Configuration Mode bar code (located on page x, at the front of this guide) 2. Scan the Character to Replace Code (shown below) 3. Scan the ASCII Code Byte value of the character you with to replace. (refer to the ASCII reference table in Section M) 4. Scan the Replacement Character bar code 5. Scan the ASCII Code Byte value of the replacement character. 6. Scan the Enter/Exit Configuration Mode bar code. (located on page x, at the front of this guide) Character to Replace
³
9
3
8
6
0
No Replacement
0
Replacement Character
³
9
3
8
7
0
0
³
8
3
8
6
0
0
Page 107
SECTION F
UPC/EAN
* Transmit UPC-A Check Digit
³
1
0
7
5
Do not Transmit UPC-A Check Digit
1
7
³
Transmit UPC-E Check Digit
³
1
0
7
5
1
0
7
5
0
* Do Not Transmit UPC-E Check Digit
1
6
³
1
0
7
5
0
Expand UPC-E to 12 Digits
* Do Not Expand UPC-E To 12 Digits
³
³
1
0
7
5
7
1
5
Expand UPC-E bar codes to the 12 digit equivalent, UPC-A bar codes.
1
0
7
5
0
6
5
Do not expand UPC-E to the 12 digit equivalent, UPC-A bar code. Code Formatting
F
1
Page 108
Code Formatting
2
F
SECTION F
UPC/EAN
Convert UPC-A to EAN-13
* Do Not Convert UPC-A to EAN-13
³
³
1
0
7
5
1
4
1
0
7
5
0
4
The scanner converts UPC-A to EAN-13 by transmitting a leading zero before the bar code.
The scanner will not convert UPC-A to EAN-13.
Transmit Lead Zero on UPC-E
Do Not Transmit Lead Zero on UPC-E
³
1
0
7
5
1
3
³
1
0
7
5
0
3
This option will transmit a zero before each UPC-E bar code.
This option will not transmit a zero before each UPC-E bar code.
Convert EAN-8 to EAN-13
* Do Not Convert EAN-8 to EAN-13
³
³
1
0
7
5
1
2
The scanner will transmit five zeros before the bar code to convert EAN-8 to EAN-13.
1
0
7
5
0
2
The scanner will not convert EAN-8 to EAN-13.
Page 109
SECTION F
UPC/EAN
* Transmit UPC-A Number System
³
1
0
7
5
Do Not Transmit UPC-A Number System
1
1
³
1
0
7
5
0
1
Metrologic strongly discourages using this feature. Duplicate numbers may result in the database.
* Transmit UPC-A MFR #
³
1
0
7
6
Do Not Transmit UPC-A MFR #
1
1
³
* Transmit UPC-A ITEM #
³
1
0
7
6
1
0
7
6
0
1
0
0
Do Not Transmit UPC-A ITEM #
1
0
³
Code Formatting
1
0
F
7
6
3
Page 110
Code Formatting
SECTION F
UPC/EAN
* Transmit EAN-8 Check Digit
³
1
0
7
9
Do Not Transmit EAN-8 Check Digit
1
0
³
* Transmit EAN-13 Check Digit
³
1
0
7
9
1
2
³
0
7
5
0
7
9
0
0
1
0
7
9
0
2
No GTIN-14 Format † †
1
1
Do Not Transmit EAN-13 Check Digit
GTIN-14 Format †
³
4
F
1
0
For MS7220, MS7320 and MS7600 scanners only.
³
1
0
7
5
0
0