Page 91

SECTION E

CONFIGURABLE ID CHARACTERS, CODE SPECIFIC

~ Configurable Code 93 ID †

~ Configurable Code 11 ID †

³

³

9

0

6

3

0

0

9

0

6

4

0

0

0

0

† While using the Multi-Code method, scan this bar code followed by the 3 code byte bar codes in Section M that represent a unique ID character to be associated with this bar code type. (Refer to the Multi-Code method on page x.)

~ Configurable Telepen ID †

~ Configurable TRI-OPTIC ID †

³

³

9

0

6

2

0

0

Prefixes/Suffixes

9

E

0

5

7

2

Page 92

Prefixes/Suffixes

SECTION E

CONFIGURABLE ID CHARACTERS, CODE SPECIFIC

~ Configurable Standard 2 of 5 ID †

³

9

0

7

1

6

E

0

~ Configurable Interleaved 2 of 5 ID †

0

³

9

0

6

7

0

0

† While using the Multi-Code method, scan this bar code followed by the 3 code byte bar codes in Section M that represent a unique ID character to be associated with this bar code type. (Refer to the Multi-Code method on page x.)

~ Configurable Matrix 2 of 5 ID †

³

9

0

6

8

~ Configurable Airline 2 of 5 ID †

0

0

³

9

0

6

9

0

0

Page 93

SECTION E

CONFIGURABLE ID CHARACTERS CODE SPECIFIC

~ Configurable MSI Plessey ID †

³

9

0

6

5

0

~ Configurable UK Plessey ID†

0

³

9

0

7

0

0

0

† While using the Multi-Code method, scan this bar code followed by the 3 code byte bar codes in Section M that represent a unique ID character to be associated with this bar code type. (Refer to the Multi-Code method on page x.)

~ Configurable Codabar ID †

³

9

0

6

* Clear all Configurable Code Specific ID’s †

6

0

0

³

Prefixes/Suffixes

9

E

9

7

9

9

8

3

Page 94

Prefixes/Suffixes

SECTION E

STANDARD PREFIX CHARACTERS

Enable STX Prefix

³

1

1

6

6

8

E

* Disable STX Prefix

1

5

³

1

1

6

6

0

5

The scanner will transmit a Start of TeXt (ASCII 02H) before each bar code.

Will not transmit a Start of TeXt (ASCII 02H) before each bar code.

Enable Rockford-Thompson Mode

* Disable RockfordThompson Mode

³

³

1

0

5

5

1

3

1

0

5

5

Enable AIM ID Characters

* Disable AIM ID Characters

³

³

1

0

7

9

1

5

The scanner will transmit AIM symbology identifiers. Some scanner models may not support this feature.

1

0

7

9

0

3

0

5

The scanner will not transmit AIM symbology identifiers.

Page 95

SECTION E

STANDARD PREFIX CHARACTERS

Enable UPC Prefix ID

³

1

1

6

6

1

* Disable UPC Prefix ID

7

³

When enabled, the scanner will transmit a prefix before any UPC/EAN bar code.

1

1

6

6

0

7

Do not send prefix ID Characters with UPC/EAN codes.

The prefixes are as follows: A (UPC-A), E0 (UPC-E), F (EAN-13), and FF (EAN-8).

Enable NCR Prefix ID

³

1

0

7

9

1

* Disable NCR Prefix ID

1

³

1

0

When enabled, the scanner will transmit a prefix before the following code types. The prefixes are as follows: A (UPC-A), E0 (UPC-E), FF (EAN-8), F (EAN-13), B1 (Code 39), B2 (ITF) and B3 (Code 128 & other codes).

Prefixes/Suffixes

E

9

7

9

0

1

Page 96

Prefixes/Suffixes

SECTION E

STANDARD PREFIX CHARACTERS

Enable Nixdorf ID Characters

³

1

0

7

9

10

E

* Disable Nixdorf ID Characters

1

7

³

1

0

7

9

0

7

This option transmits code identifiers before each bar code for many Siemens/Nixdorf registers.

This option will not transmit Siemens/Nixdorf code identifiers.

Enable SANYO ID Characters

* Disable SANYO ID Characters

³

1

0

7

9

1

6

³

1

0

7

9

0

6

Transmit Sanyo ID Characters.

Do not transmit Sanyo ID Characters.

Enable TEC Register Format ID Characters

Disable TEC Register Format ID Characters

³

1

2

4

7

1

0

³

1

2

4

7

0

0

Page 97

SECTION E

STANDARD PREFIX CHARACTERS

Enable Manufacturer ID Prefix

³

1

0

5

5

1

* Disable Manufacturer ID Prefix

2

³

1

0

5

5

0

2

Transmits “METROLOGIC” before all bar code data to identify the scanner as a Metrologic Scanner.

The scanner will not transmit the manufacturer identification string.

Enable “C” Prefix

* Disable “C” Prefix

³

1

0

5

5

1

1

³

Enable “$” Prefix ID for UPC/EAN

³

1

0

5

5

1

1

0

5

5

0

1

* Disable “$” Prefix ID for UPC/EAN

0

³

Prefixes/Suffixes

1

E

0

11

5

5

0

0

Page 98

Prefixes/Suffixes

SECTION E

STANDARD PREFIX CHARACTERS

Enable Tab Prefix

³

1

1

6

6

12

E

* Disable Tab Prefix

1

1

³

1

1

6

6

0

1

The scanner will transmit a TAB (ASCII 09H) before each bar code.

The scanner will not transmit a TAB.

Enable SNI Beetle Mode

* Disable SNI Beetle Mode

³

³

1

1

6

1

1

1

1

1

6

1

0

1

Enable Cipher 1021 IDs

* Disable Cipher 1021 IDs

³

³

1

1

6

1

1

3

1

1

6

1

0

3

Page 99

SECTION E

STANDARD SUFFIX CHARACTERS

* Enable CR Suffix

³

1

1

6

6

1

Disable CR Suffix

3

³

1

1

6

6

0

3

The scanner will transmit a Carriage Return after each bar code.

The scanner will not transmit a Carriage Return after each bar code.

* Enable LF Suffix

Disable LF Suffix

³

1

1

6

6

1

2

³

The scanner will transmit a Line Feed after each bar code.

1

1

6

6

0

2

The scanner will not transmit a Line Feed after each bar code.

This feature is Disabled when keyboard wedge defaults are loaded.

Enable Tab Suffix

³

1

1

6

6

* Disable Tab Suffix

1

0

³

The scanner will transmit a TAB (ASCII 09H) after each bar code.

1

1

6

6

0

0

The scanner will not transmit a TAB (ASCII 09H) after each bar code. Prefixes/Suffixes

E

13

Page 100

Prefixes/Suffixes

SECTION E

STANDARD SUFFIX CHARACTERS

Enable ETX Suffix

³

1

1

6

6

14

E

* Disable ETX Suffix

1

4

³

1

1

6

6

0

4

The scanner will transmit End of TeXt (ASCII 03H) after the bar code data.

The scanner will not transmit End of TeXt (ASCII 03H).

Enable UPC Suffix ID

* Disable UPC Suffix ID

³

1

1

6

6

1

6

The scanner will transmit a suffix after any UPC/EAN bar code. The suffixes are as follows: A (UPC-A), E (UPC-E), F (EAN-13) and F (EAN-8).

³

1

1

6

6

0

The scanner will not transmit a suffix after UPC/EAN bar codes.

6