Page 17

SECTION 3. OPERATION This section contains check and card reading and cleaning procedures and LED indicator states. CHECK READING PROCEDURE 1.

Orient the check so the MICR line is down and the printed side faces the center of the MICRImage as indicated in Figure 3-1.

2.

Drop the check so the leading edge is in the open slot. Slide the check forward.

3.

When the MICRImage detects the presence of the check, the motor will turn on. At this time gently urge the check forward until the unit grabs the check. When this happens, release the check. The check will then be transported around the check path and will exit through the other side.

4.

After the check is read, the MICRImage will transmit the data as specified by the parameters.

5.

Remove the check. Slide Check Forward Until Reader Pulls Check In 2 Slowly Check Flush 1 Place Onto Entry Slot

Figure 3-1. Check Orientation - Insertion 9

Page 18

MICRImage Check Reader

CARD READING PROCEDURE 1.

Orient the card so that the magnetic stripe is down and facing away from the logo on the unit and toward the wide color stripe on the MRS, as indicated in Figure 3-2.

2.

Slide the card in one motion from the top of the unit down through the slot as indicated in the illustration.

3.

After the card is read, the MICRImage will transmit the data as specified by the parameters.

Figure 3-2. Optional Magnetic Swipe Reader Orientation

10

Page 19

Section 3. Operation

LED INDICATORS Table 3-1 describes the LED indicator conditions for check and card reading operations. The LED indicator is located below the slot where the check is first inserted for reading. Table 3-1. LED indicators LED INDICATOR DESCRIPTION OFF Power off SOLID GREEN Ready to read check or card Check read error OFF→ SOLID RED Good read OFF→ SOLID GREEN FLASH GREEN Needs initialization* FLASH RED/GREEN Magnetic Interference Detected FLASH RED/GREEN Data sensor blocked (motor does not run)* FLASH RED Motor sensor blocked (motor does not run)* *Refer to “Section 4. Troubleshooting Guide.”

CLEANING Clean the outside of the MICRImage unit with a soft, damp cloth and wipe with a dry cloth. Caution To avoid damaging the read head, do not get the inside of the check or card paths wet. Use the Cleaning Card, P/N 96700004, on the MSR as described below. Use the Cleaning Swab, P/N 97200078, to clean the Imager Scan Bar as shown and described below. Opening the Unit To open the check path and Imager, grip the access latch, and pull up and then back as shown in Figure 3-3. MSR Cleaning Card Orient the cleaning card similar to Figure 3-2. Swipe the card two or three times to clean the head.

11

Page 20

MICRImage Check Reader

Pull Latch Up Then Back Easy-Access Latch

Figure 3-3. Opening the Unit Cleaning Check Path and Imager 1.

When the unit is open, as shown in Figure 3-4, check the path for debris. To clean, turn the unit over and tap gently on the bottom. Imager Alignment Alignment Hole Pin

Easy-Access Latch

Figure 3-4. Cleaning Check Path and Imager 2. 12

Check the Imager to ensure there is no build-up of ink or paper debris.

Page 21

Section 3. Operation

3.

To clean the Imager, use the cleaning swab, shown in Figure 3-5. Activate the swab by bending the plastic tube until you hear a snap.

Figure 3-5. Activating the Cleaning Swab 4.

Wait until the liquid moves into the sponge tip. It should be damp when touched.

5.

When the tip of the swab is damp, clean the Imager by wiping the swab up and down the Imager as indicated in Figure 3-6.

Figure 3-6. Cleaning the Imager

13

Page 22

MICRImage Check Reader

Closing the Unit 1. Hold the unit as shown in Figure 3-7. Push the covers together while ensuring alignment of the pin and hole. 2. The unit is properly closed when the two panels are flush and the latch has "clicked" into position.

Imager Alignment Alignment Pin Hole

To Close: Push Panel Back And Ensure Alignment Pin And Hole Match.

Easy-Access Latch

Figure 3-7. Closing the Unit