MICRImage Check Reader Technical Reference Manual: SECTION 2. INSTALLATION

Pages 13 to 16 of 38, from MICRImage Check Reader Technical Reference Manual

The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the MagTek MICRImage

Page 13

SECTION 2. INSTALLATION The installation for the MICRImage Check Reader is described below. Figure 2-1 shows the unit with the MSR.

Card Path

Easy-Access Latch Check Path

LED

Figure 2-1. MICRImage with MSR REQUIREMENTS The following is required for the Installation:

• MICRImage • Interface Cable, • Power Adapter 12 VDC, 1.5 Amp

5

Page 14

MICRImage Check Reader

CABLING PROCEDURE The pin lists for all connections are shown in Appendix A. Perform the following steps: 1.

Connect the male DB25 connector to the MICRImage as shown in Figure 2-2.

Easy-Access Latch LED

Pin 1

Pin 14

Pin 13

Pin 25 Pin 13 Pin 25

Pin 14

Pin 1

Figure 2-2. DB25 Connection 2.

Connect the DB9 connector to the PC as shown in Figure 2-3, 2-4, and 2-5.

3.

Connect RJ45 Jack to the network connection as indicated in Figure 2-5.

4.

On the AC power adapter, connect the jack to the plug on the cable.

5.

On the AC power adapter, connect the plug to the wall outlet.

6.

The LED indicator on the MICRImage Reader should turn on to a steady green. The LED indicator is located on the slot where the check is first inserted for reading (see Figure 2-1).

6

Page 15

Section 2. Installation

Caution Do not place the MICRImage Reader within 6 inches of a computer monitor or power supply. These devices may cause undesirable interference with the check reading operation. For a single PC, install the MICRImage cables as shown in Figure 2-3.

P/N 22410302

MICRImage

12 VDC Power Adapter

Figure 2-3. Cabling – Single PC

7

Page 16

MICRImage Check Reader

For a Terminal and Auxiliary Device, install the MICRImage cables as shown in Figure 2-4.

12 VDC Power Adapter

P/N 22410306

Terminal

MICRImage

RS-232 Peripheral

Figure 2-4. Cabling –Terminal and Auxiliary Device For a PC and Network connection, install the MICRImage cables as indicated in Figure 2-5.

12 VDC Power Adapter

MICRImage

P/N 22410307 (Ethernet) or 22410310 (Modem)

To Network Connection or Phone Jack

Figure 2-5. Cabling – PC and Ethernet or Modem Connection 8