Page 1 of MICRImage Check Reader Technical Reference Manual

Manual · MagTek

MICRImage Check Reader Technical Reference Manual

Manual38 pagesPDF 1.1 MB

Technical reference manual for the MagTek MICRImage check reader and imager: configurations, specifications, installation and operation.

Download the PDF1.1 MB

Covers · 1 model

The models it covers

Summary

What is in it

The technical reference manual for the MagTek MICRImage Check Reader, which reads the MICR line at the bottom of a check and produces a digitized image of the whole check for a host system. It lists the configurations (RS-232, Ethernet, V.34 modem, optional 3-track card reader), features, accessories and specifications, then covers installation and cabling, check and card reading, LED indicators, cleaning, troubleshooting, interface cable pin lists, ASCII codes and check layouts.

Its parts

  1. Overview
  2. Installation
  3. Operation
  4. Troubleshooting Guide

From the manual

Key facts from this manual

Each line names its page in the PDF.

Technical reference manual for the MagTek MICRImage check reader, which reads the MICR line and images the check. It gives the features, accessories and specifications, then covers cabling, reading checks and cards, the LED indicators, cleaning, a step-by-step troubleshooting guide and the interface cable pin list.

Read for this summary: pages 1 to 2, 4 and 9 to 31 of 38.

What it is
MICR check reader that also images the whole check in a single pass and sends both to a host p. 9
Interfaces
RS-232 (dual RS-232 support, one path for MICR and one for image data); models with Ethernet or V. 34 modem p. 9, 10
Power
AC power adapter with cable, 120VAC to 12 VDC, 1.5 Amp, Part Number 64300090 p. 10
MICR fonts
E13-B and CMC-7; Enhanced Reading compares up to 3 reads p. 9, 10
Imaging
200 dpi image of the entire front of the check; CCITT G4 compression; whole image or user-specified portions p. 10
Card reader
Optional three-track MSR that tells ISO, CDL and AAMVA card formats apart p. 9
Data output
MICR data sent as ASCII characters, with automatic parsing of fields such as transit and account p. 9
Interface cables
22410302 RS-232 with DB9 female host end; 22410306 for a terminal and auxiliary device; 22410307 Ethernet; 22410310 modem p. 16, 23
Accessories
MICRbase Program 22000021; sample checks 96530005; cleaning cards 96700004; cleaning swabs 97200078 p. 10
Reader connector
DB25 connector on the reader end of the cable p. 14
Document size
4"x 8.5" maximum p. 2, 11
Size and weight
Length 9.0”, Width 3.9”, Height 6.0”; 2.5 lbs. p. 11
Rated life
Electronics 125,000 hours; check read head and MSR read head 1,000,000 passes each p. 11

What this manual walks you through

  • Connecting the cables and power adapter p. 14
  • Cabling for a single PC, a terminal with an auxiliary device, or a PC with Ethernet or modem p. 15, 16
  • Feeding a check through the reader p. 17
  • Swiping a card through the optional MSR p. 18
  • Reading the LED indicator p. 19
  • Cleaning the MSR head, check path and imager p. 19, 20, 21
  • Step-by-step troubleshooting with the MICRbase program p. 23, 24, 25, 26, 27, 28
  • DB9 to DB25 interface cable pin list p. 31

Good to know

  • Keep the reader at least 6 inches from a computer monitor or power supply, which can disturb check reading. p. 15
  • Do not get the inside of the check or card paths wet; it can damage the read head. p. 19
  • Let go of the check as soon as the reader grabs it. p. 25

Questions this manual answers

What power adapter does the MagTek MICRImage use?

An AC adapter, 120VAC to 12 VDC, 1.5 Amp, Part Number 64300090. p. 10

What does a flashing red light mean on the MICRImage?

The motor sensor is blocked and the motor does not run; the troubleshooting guide says to clean the sensor with forced air. p. 19, 27

Why does my MICRImage read checks but send no data?

Check in MICRbase that Send Data After Error is YES and that Use CTS/DSR is set to IGNORE unless those signals are enabled. p. 25

Which cable connects the MICRImage to a PC?

Interface cable 22410302, with a DB9 female host end and a DB25 connector at the reader. p. 23

Does the MICRImage read CMC-7 checks?

Yes, it reads both E13-B and CMC-7 MICR fonts. p. 10

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. MICRImage1
    1. CHECK READER1
  2. Manual Part Number: 99875173 Rev 81
  3. OCTOBER 20081
    1. REGISTERED TO ISO 9001:20001
  4. REVISIONS2
  5. SECTION 1. OVERVIEW9
    1. CONFIGURATION9
    2. FEATURES9
    3. ACCESSORIES10
    4. SPECIFICATIONS10
  6. SECTION 2. INSTALLATION13
    1. REQUIREMENTS13
    2. CABLING PROCEDURE14
  7. SECTION 3. OPERATION17
    1. CHECK READING PROCEDURE17
    2. CARD READING PROCEDURE18
    3. LED INDICATORS19
    4. CLEANING19
  8. SECTION 4. TROUBLESHOOTING GUIDE23
    1. REQUIREMENTS23
    2. SET-UP23
  9. APPENDIX A. INTERFACE CABLE PIN LISTS31
  10. APPENDIX B. ASCII CODES33
  11. APPENDIX C. CHECK READING35
    1. E13-B CHARACTER SET35
    2. CMC-7 CHARACTER SET35
    3. CHECK LAYOUTS36
    4. MICR FIELDS37

From the PDF’s own bookmarks.

The whole text · 7 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 81-8
  2. SECTION 1. OVERVIEW9-12
  3. SECTION 2. INSTALLATION13-16
  4. SECTION 3. OPERATION17-22
  5. SECTION 4. TROUBLESHOOTING GUIDE23-30
  6. Pages 31 to 3431-34
  7. APPENDIX C. CHECK READING35-38

The file

Revision and size

RevisionManual Part Number: 99875173 Rev 8, October 2008
PublisherMagTek, Inc.
Pages38
PDF1.1 MB
TextText from the PDF itself.

The first pages · 3 of 38

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 38
Page 2
Page 2of 38
Page 3
Page 3of 38