The text of a manual · part 87 of 105
Catalog: Optical electronic sensors: Contrast Scanners – Colour Sensors – Luminescence Scanners, pages 839 to 848
Pages 839 to 848 of 1000, from Catalog: Optical electronic sensors
The original document is the PDF (46 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Leuze FRK 92, Leuze PRK406 and Leuze PRK 3
Page 839
Leuze electronic KRTG 20
Order code Í
Equipment Ï Scanning range
Transmitter colour Light spot orientation
Optical outlet Output wiring
Other features
12mm 20mm 50mm RGB green vertical horizontal round front head PNP NPN analogue voltage analogue current static teach-in dynamic teach-in, standard dynamic teach-in with marker preselection teach-in, background synchronous input
KRTG 20M/N-20-1820-S12 Part No. 500 36506
Selection table
KRTG 20M/P-20-1820-S12 Part No. 500 36504
Preferred types l l l l l l l l l l l l l l
Additional types on request
KRTG 20… - 01 Teach-in, background
0202
– 839 –
Page 840
Leuze electronic KRTG 8
Green light contrast scanner Dimensioned drawing
10mm 10 - 30 V DC
10 kHz l Static teach-in procedure l Switching frequency 10,000 Hz l Green transmission LED l M12 turning connector
We reserve the right to make changes • 8_e02e.fm
ISO 9001
A B C D E F G
Transmitter Receiver Optical axis Operational control LED green LED yellow 90° turning connector
IP 67
Electrical connection IEC 60947...
IEC 60947...
Accessories: (available separately • see page 856)
l M12 connectors (KD …) l Cable (KB …) l Mounting systems
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 840 –
KRTG 8/24 … - 01
Page 841
Page 842
Leuze electronic KRTG 8 Controls and indicators a b c d e f g
Step switch
Switch position Run Switch position + Switch position Teach Switch position Delay Switch position Operation and teach indicator (LED green) Object/light path (LED yellow)
Function
Run
Teach and Run position for marker contrast
Teach
Teach position for background contrast
+
Switching threshold is increased by +5%
-
Switching threshold is reduced by -5%
Delay
Activate/deactivate 10ms pulse stretching
The step switch must be set to > 1s to allow the individual functions to be activated.
Signal propagation Label Switch position Teach Switch position Run LED yellow Switching output with light switching
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 842 –
KRTG 8/24 … - 01
Page 843
Leuze electronic KRTG 8 Teach procedure for statical teach-in Operation
Transmitter
LED green LED yellow
1
Position the light spot on the background
Green light spot visible
ON
ON/OFF
2
Switch the step switch from Run -> Teach
Green light spot visible
3Hz
OFF
3
Position the light spot on the marker
Green light spot visible
3Hz
OFF
4
Switch the step switch from Teach -> Run
Green light spot visible
3Hz
OFF
Teach-in successful
Green light spot visible
ON
ON
Teach-in error
Green light spot flashes with 3Hz OFF
3Hz
The step switch must be set to > 1s to allow the individual functions to be activated.
Changing the switching threshold Operation
Transmitter
LED green LED yellow
1
Step switch in position Run
Green light spot visible
ON
ON/OFF
2
Switch the step switch from Run -> (+/-)
Green light spot visible
OFF
OFF
3
Sensitivity is changed in steps of 5% each
Green light spot visible
1Hz
OFF
4
Switch the step switch from (+/-) -> Run
Green light spot visible
ON
ON/OFF
In switch position (+), the switching threshold is increased by 5% every second. In switch position (-), the switching threshold is increased by 5% every second. Modification of switching threshold activated:green LED = 1Hz Maximum value switching threshold reached:LED green = ON Minimum value switching threshold reached:LED green = OFF
Pulse stretching on/off Operation
Transmitter
LED green LED yellow
1
Step switch in position Run
Green light spot visible
ON
ON/OFF
2
Switch the step switch from Run -> Delay
Green light spot visible
OFF
ON/OFF
3
Status display of the pulse stretching
Green light spot OFF
10Hz
Status display: ON=Delay active OFF=Delay not active
4
10s waiting time before switching After 10s delay value modified
Green light spot OFF
10Hz
Status display: ON=Delay active OFF=Delay not active
5
Switch the step switch from Delay -> Run
Green light spot visible
ON
ON/OFF
KRTG 8/24 … - 01
0208
– 843 –
Page 844
Leuze electronic CRT 448
Colour sensors with digital outputs Dimensioned drawing
40mm 10 - 30 V DC l Scanner with visible light spot for colour detection l Independent teach-in of up to 4 reference colours (channels) l Separately adjustable tolerance steps for each colour (channel) l Easy adjustment through clearly organised control panel with 3 buttons or via control input
We reserve the right to make changes • FMT_CRT01e.fm
A B C
ISO 9001
Scanning range Transmitter axis Receiver axis
Electrical connection IP 67
1,6 kHz IEC 60947...
IEC 60947...
Accessories: (available separately • see page 856)
l M12 connectors, 8-pin (KD …) l Ready-made cables (KB …)
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 844 –
CRT 448 - 02
Page 845
Page 846
Leuze electronic CRT 448 Function principle of the colour sensor Many sensors are capable of differentiating between light and dark or matt and shiny. As soon as colour is to serve as a distinguishing criterium, however, normal sensors are quickly pushed to their limits. As a result, colour sensors are of increasing importance in industrial automation. The applications range from sorting coloured objects to the detection or inspection of coloured surfaces. Materials such as powders, granulates, fluids as well as metals, glasses, papers, plastics and textiles can be reliably detected in this way. Simple operation makes it possible to teach-in the reference colour and to adjust the tolerance range. During operation, the colour sensor compares the taught-in colour with the measured colour. If the values lie within the set tolerance range, the sensor passes on the match to the controller via a switching output.
Controls and indicators Indicator LED CH (yellow)
Button for channel selection (CH button) CH
Indicator LED TOL (green)
TOL
Button for tolerance selection (TOL button)
Indicator LED SET (orange)
SET
Button for teach mode (SET button)
Indicator LED CH4 x yellow
Run mode Switching state display of output/channel 1 to 4. Run mode is indicated by illumination of all LEDs.
TOL3 x green SET1 x orange
Control button CH button for channel selection TOL button for tolerance selection SET button for teach mode
Teach-in mode Display of the selected channel from 1 to 4. Display of the selected tolerance level (1 … 5) of the selected channel. Illuminated LED indicates the teach mode. Flashing LED indicates measurement in progress. Slowly or fast flashing LED indicates errors during the measurement procedure.
Run mode Without function
Teach-in mode a) selection of the next channel b) back to run mode on error Without function a) selection of the next level with higher tolerance b) back to run mode on error The device changes to teach mode after the a) measurement procedure is started. button is pressed for more than 1.5s. b) the values are stored and the device goes back to run mode
Run mode/operating mode The sensor is in run mode after application of the operating voltage. - All three green tolerance LEDs (TOL-LEDs) are illuminated - The four yellow LEDs (CH-LEDs) display the state of the outputs (channels)
Manual teach-in mode To teach the colours and the tolerance level, proceed as follows: 1. Position the sensor correctly towards the object (scanning distance, angle, etc.). 2. Pressing the SET button for at least 1.5s switches the sensor to the teach mode and switches on the orange SET LED. 3. Pressing the CH button always selects the next channel, which is indicated by the associated yellow LED. Channel 1 follows channel 4. 4. Pressing the TOL button always selects the next-higher tolerance level (1 to 5), which is indicated by the corresponding green LED(s). Tolerance level 1 follows tolerance level 5. Tolerance levels: Tolerance level 1 Tolerance level 2 For distinguishing between subtle differences in colour
Leuze electronic GmbH + Co. http://www.leuze.de
Tolerance level 3
Tolerance level 4
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 846 –
Tolerance level 5 For distinguishing between coarse differences in colour
CRT 448 - 02
Page 847
Page 848
Leuze electronic CRTM 20
Colour sensors with analogue output Dimensioned drawing
12mm 20mm 50mm 12 - 30 V DC l Scanner for colour detection with analogue output l Red, green, and blue measurement via just one analogue output l Remote changeover of transmitter colours
We reserve the right to make changes • FMT_CRT02e.fm
A B C D E F
ISO 9001
Light spot orientation vertical Optical axis M5/5.5mm deep Scanning range Front Head
Electrical connection IP 67
25 kHz IEC 60947...
IEC 60947...
Accessories: (available separately • see page 856)
l M12 connector, 5-pin (KD …) l Interchangeable objectives l Tool for changing objectives
Leuze electronic GmbH + Co. http://www.leuze.de
Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730
– 848 –
CRTM 20M/V-50-0001-S12 - 02