Page 829

The text of this page cannot be shown here; see it in the PDF.

Page 830

Leuze electronic KRTG 20 Function principle of the contrast scanner These contrast scanners are devices which, with the aid of a green LED transmitter, can differentiate between extremely small differences in contrast (grey scale values). Their dynamic range is much wider compared to known devices. This is made possible by automatic amplifier adaptation and use of several transmission levels (brightnesses). In this way any number of marker/background combinations can be detected with remarkably increased functional safety. Shiny markers can be safely detected. By continuously measuring and regulating the emitted light, the devices are able to function in a very temperature-stable manner. The marker does not, as a result, need to be retaught. The diaphragm mounted in front of the receiver and the extremely bright light spot guarantee a high reproducibility and precision in positioning. With this teaching type, background and marker must be placed statically below the light spot. Using the synchronisation input, the switching output can be activated or deactivated.

Controls and indicators LED ON (green) for "Ready"

LED Q/T (yellow) for "Object detected" and "Error display" (flashing)

LED Delay (green) for pulse stretching 20ms (LED=ON) LED L/D (green) for dark switching (LED=ON)

Switching threshold with preset dark markers Label Teach Sync Q/T Switching output with light switching Switching output with dark switching

Teach process The teach process is performed with the aid of the teach button or external teach lines. The two processes work in the same way. Operation

Transmitter

Position the light spot on the background

Green light spot visible

Press the teach button approx. 1s or set the teach line to high level

Green light spot visible

All LEDs flash

Position the light spot on the marker

All colours are on White light spot is visible

All LEDs flash

Press the teach button approx. 1s or set the teach line to low level

Green light spot visible

ON (green) illuminated Q/T (yellow) off Q/T (yellow) flashing (error)

Teaching error start new teaching process

No light spot visible

ON (green) illuminated Q/T (yellow) flashing (error)

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 830 –

Indicator LED

KRTG 20… - 01 Static teach-in

Page 831

Leuze electronic KRTG 20

Transmitter colour Light spot orientation

Optical outlet Output wiring

Other features l

KRTG 20M/V-50-1626-S12 Part No. 500 34931 l

KRTG 20M/V-50-1526-S12 Part No. 500 34930 l

KRTG 20M/N-50-1320-S12 Part No. 500 32797 l

KRTG 20M/P-50-1320-S12 Part No. 500 32793 l

KRTG 20M/V-20-1626-S12 Part No. 500 34929 l

KRTG 20M/V-20-1526-S12 Part No. 500 34928 l

KRTG 20M/N-20-1320-S12 Part No. 500 32796 l

KRTG 20M/P-20-1320-S12 Part No. 500 32792

12mm 20mm 50mm RGB green vertical horizontal round front head PNP NPN analogue current static teach-in dynamic teach-in, standard dynamic teach-in with marker preselection teach-in, background synchronous input

KRTG 20M/V-12-1626-S12 Part No. 500 32789

Equipment Ï Scanning range

KRTG 20M/V-12-1526-S12 Part No. 500 32787

Order code Í

KRTG 20M/N-12-1320-S12 Part No. 500 32795

Selection table

KRTG 20M/P-12-1320-S12 Part No. 500 32791

Preferred types l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l

Additional types on request

KRTG 20… - 01 Static teach-in

0202

– 831 –

Page 832

Leuze electronic KRTG 20

Green light contrast scanner Dimensioned drawing

12mm 20mm 50mm 12 - 30 V DC l Standard dynamic teach-in procedure l Switching frequency 25,000Hz l Green transmitter LED with variable brightness l Programming by means of teach-in (via button or remote calibration)

We reserve the right to make changes • FMT_KRT05e.fm

A B C D E F

ISO 9001

Light spot orientation vertical Optical axis M5/5.5mm deep Scanning range Front Head

Electrical connection IP 67

25 kHz IEC 60947...

IEC 60947...

Accessories: (available separately • see page 856)

l M12 connectors, 5-pin (KD …) l Interchangeable objectives l Tool for changing objectives

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 832 –

KRTG 20… - 01 Dynamic teach-in, standard

Page 833

The text of this page cannot be shown here; see it in the PDF.

Page 834

Leuze electronic KRTG 20 Function principle of the contrast scanner These contrast scanners are devices which, with the aid of a green LED transmitter, can differentiate between extremely small differences in contrast (grey scale values). Their dynamic range is much wider compared to known devices. This is made possible by automatic amplifier adaptation and use of several transmission levels (brightnesses). In this way critical marker/background combinations can be detected with remarkably increased functional safety. Shiny markers can be safely detected. By continuously measuring and regulating the emitted light, the devices are able to function in a very temperature-stable manner. The marker does not, as a result, need to be retaught. The diaphragm mounted in front of the receiver and the extremely bright light spot guarantee a high reproducibility and precision in positioning. With this teaching type, the teaching process must be started on the background. Using the synchronisation input, the switching output can be activated or deactivated. Adaptation of the taught switching threshold is performed as described under Remarks. See also Remarks and Diagrams

Controls and indicators LED ON (green) for "Ready"

LED Q/T (yellow) for "Object detected" and "Error display" (flashing)

LED Delay (green) for pulse stretching 20ms (LED=ON) LED L/D (green) for dark switching (LED=ON)

Signal propagation After activating the teaching function, the markers have to be moved past the sensor for at least one pattern length. The teaching process must be started on the background and can be stopped anywhere. The sensor scans the paper in 10ms intervals and reveals the minimum and maximum contrast. After completing the teaching function, the switching threshold is set.

Centered switching threshold Pattern length

Label Teach input/teach button Received signal Switching threshold Synchronous input LED Q/T Switching output with light switching Switching output with dark switching

Switching threshold close to marker contrast Pattern length

Label Teach input/teach button Received signal Switching threshold Synchronous input LED Q/T Switching output with light switching Switching output with dark switching Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 834 –

KRTG 20… - 01 Dynamic teach-in, standard

Page 835

Leuze electronic KRTG 20 Teach process The teach process is performed with the aid of the teach button or external teach lines. The two processes work in the same way. Operation

Transmitter

Indicator LED

Position the sensor above the background

Green light spot visible

Press the teach button approx. 1s or set the teach line to high level

Green light spot visible

All LEDs flash

Move paper sheet for at least one pattern length

Green light spot visible

All LEDs flash

Press the teach button approx. 1s or set the teach line to low level

Green light spot visible

ON (green) illuminated Q/T (yellow) off Q/T (yellow) flashing (error)

Teaching error start new teaching process

No light spot visible

ON (green) illuminated Q/T (yellow) flashing (error)

Transmitter colour Light spot orientation

Optical outlet Output wiring

Other features l

KRTG 20M/V-50-1428 -S12 Part No. 500 34940 l

KRTG 20M/V-50-1427-S12 Part No. 500 34939 l

KRTG 20M/N-50-1420-S12 Part No. 500 34951 l

KRTG 20M/P-50-1420-S12 Part No. 500 34950 l

KRTG 20M/V-20-1428-S12 Part No. 500 34938 l

KRTG 20M/V-20-1427-S12 Part No. 500 34937 l

KRTG 20M/N-20-1420-S12 Part No. 500 34949 l

KRTG 20M/P-20-1420-S12 Part No. 500 34948

12mm 20mm 50mm RGB green vertical horizontal round front head PNP NPN analogue voltage analogue current static teach-in dynamic teach-in, standard dynamic teach-in with marker preselection teach-in, background synchronous input

KRTG 20M/V-12-1428-S12 Part No. 500 34936

Equipment Ï Scanning range

KRTG 20M/V-12-1427-S12 Part No. 500 34935

Order code Í

KRTG 20M/N-12-1420-S12 Part No. 500 34947

Selection table

KRTG 20M/P-12-1420-S12 Part No. 500 34946

Preferred types l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l

Additional types on request

KRTG 20… - 01 Dynamic teach-in, standard

0202

– 835 –

Page 836

Leuze electronic KRTG 20

Green light contrast scanner Dimensioned drawing

12mm 20mm 50mm 12 - 30 V DC l Teach-in only on background l Switching frequency 25,000Hz l Green transmitter LED with variable brightness l Programming by means of teach-in (via button or remote calibration) l Detection of bright and dark contrasts

We reserve the right to make changes • FMT_KRT06e.fm

A B C D E F

ISO 9001

Light spot orientation vertical Optical axis M5/5.5 mm deep Scanning range Front Head

Electrical connection IP 67

25 kHz IEC 60947...

IEC 60947...

Accessories: (available separately • see page 856)

l M12 connectors, 5-pin (KD …) l Interchangeable objectives l Tool for changing objectives

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 836 –

KRTG 20… - 01 Teach-in, background

Page 837

The text of this page cannot be shown here; see it in the PDF.

Page 838

Leuze electronic KRTG 20 Function principle of the contrast scanner These contrast scanners are devices which, with the aid of a green LED transmitter, can differentiate between extremely small differences in contrast (greyscale values). Their dynamic range is much wider compared to known devices. This is made possible by automatic amplifier adaptation and use of several transmission levels (brightnesses). In this way, critical marker/background combinations can be detected with considerably increased functional safety. Shiny markers can be safely detected. By continuously measuring and regulating the emitted light, the devices are able to function in a very temperature-stable manner. The marker does not, as a result, need to be retaught. The diaphragm mounted in front of the receiver and the extremely bright light spot guarantee a high reproducibility and precision in positioning. With this teaching type, the teaching process must only be performed on the background. Using the synchronisation input, the switching output can be activated or deactivated. Adaptation of the taught switching threshold is performed as described under Remarks. See also Remarks and Diagrams

Controls and indicators LED ON (green) for "Ready"

LED Q/T (yellow) for "Object detected" and "Error display" (flashing)

LED Delay (green) for pulse stretching 20ms (LED=ON) LED L/D (green) for dark switching (LED=ON)

Signal propagation When the teach function is activated, the background must be statically positioned under the sensor. The switching threshold lies above and below the teach value. Upon conclusion of the teach function, the switching threshold is set on both sides of the background contrast. The switching threshold (sensitivity) can be changed, see remarks for additional information. Label Teach input/teach button Upper switching threshold Background contrast Lower switching threshold Synchronous input LED Q/T Switching output with light switching Switching output with dark switching

Teach process The teach process is performed with the aid of the teach button or external teach lines. The two processes work in the same way. Operation

Transmitter

Position the sensor above the background

Green light spot visible

Press the teach button approx. 1s or set the teach line to high level

Green light spot visible

All LEDs flash

Release the teach button or set the teach line to low level

Green light spot visible

ON (green) illuminated Q/T (yellow) off Q/T (yellow) flashing (error)

Teaching error start new teaching process

No light spot visible

ON (green) illuminated Q/T (yellow) flashing (error)

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 838 –

Indicator LED

KRTG 20… - 01 Teach-in, background