Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 88 of 105

Catalog: Optical electronic sensors: Contrast Scanners – Colour Sensors – Luminescence Scanners, pages 849 to 858

Pages 849 to 858 of 1000, from Catalog: Optical electronic sensors

The original document is the PDF (46 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Leuze FRK 92, Leuze PRK406 and Leuze PRK 3

Page 849

The text of this page cannot be shown here; see it in the PDF.

Page 850

Leuze electronic CRTM 20 Function principle of the colour sensor This colour sensor is a device which relays the object colour to the control system via just one analogue output through the use of multiple transmitter colours. For this purpose, the transmitter colours (red, green, blue) must be changed over. The corresponding colour values (RGB) of the object are then output in sequence at the analogue output. The control system needs to supply just one analogue input and one digital output. The otherwise standard, three-channel analogue analysis, which requires a considerable amount of hardware, is thus not necessary. The currently activated transmitter colour is output via RGB-Out. Each transmitter colour consists of 4 LEDs. An elongated light spot containing four dots is thereby formed at the focal point. In the event that inhomogenous colours are detected, the light spot can be defocused by slightly changing the scanning distance in such a way that a homogenous, rectangular light spot is formed.

Controls and indicators

LED ON (green) for "Ready"

LED Q/T (yellow) "error indicator" (flashing) or white calibration

The Teach, Delay and LD buttons are not active

Signal propagation Parameterising the transmitter colour via pin 5 (RGB-In) RGB changeover Transmitter colour A=green

B=red

C=blue

Feedback of the transmitter colour via pin 4 (RGB-Out)

green red blue

White calibration The device is delivered with a 50mm objective. White calibration was performed prior to delivery for this scanning range. 12mm, 20mm and 50mm objectives are available. The scanning range and light-spot geometry can, in this way, be adjusted for the given application. White calibration should be performed again after changing the objective. This is done by positioning a sheet of white paper (90%) at the appropriate scanning range (12mm, 20mm or 50mm) below the light spot. Then simultaneously press the Delay and L/D buttons for approx. 5sec. The sensor acknowledges the new white calibration by briefly flashing the Q/T LED. The entire dynamic range of the sensor is then also available for the changed scanning range. Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 850 –

CRTM 20M/V-50-0001-S12 - 02

Page 851

Leuze electronic CRTM 20 Selection table

Order code Í

Equipment Ï Scanning range

Transmitter colour Light spot orientation

Optical outlet Output wiring

Other features

12mm 20mm 50mm RGB green vertical horizontal round front head PNP NPN analogue voltage analogue current RGB transmitter can be changed over

CRTM 20M/V-50-0001-S12 Part No. 500 36094

Preferred types l l l l l l

Additional types on request

CRTM 20M/V-50-0001-S12 - 02

0202

– 851 –

Page 852

Leuze electronic LRT 440

Luminescence scanner Dimensioned drawing

0 … 70mm 0 … 120mm 0 … 300mm 10 - 30 V DC l LED with UV light l Detection of luminescent objects and markings l Round light spot l Various filterings l Large scanning range l Analogue output

We reserve the right to make changes • FMT_LRT01e.fm

A B C

ISO 9001

IEC 60947...

Control button panel Indicator diode Optical axis

Electrical connection IP 65

IEC 60947...

without analogue output with analogue output

Accessories (available separately • see page 856)

l M12 connectors (KD …) l Ready-made cables (KB …) (part of the delivery contents):

l 2m connection cable

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 852 –

LRT 440… - 02

Page 853

The text of this page cannot be shown here; see it in the PDF.

Page 854

Leuze electronic LRT 40

Luminescence scanner Dimensioned drawing LRT 40/4-10-04, 5000

2 … 40mm

A B C D

Indicator diode Transmitter Receiver Optical axis

10 - 30 V

LRT 40/4-10-14

DC l LED with UV light l Detection of luminescent objects and markings l Round light spot l Various filterings l Large scanning range

We reserve the right to make changes • FMT_LRT02e.fm

A B

ISO 9001

C D E

Indicator diode Sensitivity adjustment Transmitter Receiver Optical axis

IP 65

Electrical connection IEC 60947...

IEC 60947...

LRT 40/4-10-04, 5000

Accessories (available separately • see page 856)

l M12 connectors (KD …) l Ready-made cables (KB …) (part of the delivery contents):

l 2m connection cable

Leuze electronic GmbH + Co. http://www.leuze.de

LRT 40/4-10-14

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 854 –

LRT 40… - 01

Page 855

The text of this page cannot be shown here; see it in the PDF.

Page 856

Accessories

Leuze electronic

KRTM[G], CRT[M], LRT

Accessories

M12 connectors

Dimensioned drawings

For devices with M12 connectors, there are available: 2 connectors with ready-made 5m cable and 2 connectors with screw connection.

Additional information in section "Accessories" from page 925 onwards!

Protection class (DIN 40050) plugged and screwed: IP 67 Important: With throughbeam photoelectric sensors, a connector is required both for the transmitter and the receiver.

Selection table M12 connectors with cable (5m, 5-pin)

without cable

KB 095-5000-5

KB 095-5000-5A

KD 095-5

KD 095-5A

Part No. 500 20500

Part No. 500 20499

Part No. 500 20502

Part No. 500 20501 with cable (2m/5m, 8-pin) KB 448-2000-8A Part No. 500 32411

KB 448-5000-8A

We reserve the right to make changes • fmt_zu_e.fm

Part No. 500 33061

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 856 –

Accessories KRTM[G], CRT[M], LRT - 01

Page 857

Leuze electronic KRTM[G], CRT[M], LRT Dimensioned drawings

Mounting systems

UMS 96

UMS 96 (Part No. 500 26204)

A A

A

Sensor

OB-12 (Part No. 500 34051) OB-20 (Part No. 500 34050) OB-12

OB-20

OB-50

WZ-OB

OB-50 (Part No. 500 34049)

WZ-OB (Part No. 500 34118)

Accessories KRTM[G], CRT[M], LRT - 01

0202

– 857 –

Page 858

Leuze electronic

Leuze electronic GmbH + Co. http://www.leuze.de

Post-box 1111 D-73277 Owen-Teck Tel. ++49 7021 5730

– 858 –