Manual · Leuze
MA 21 connector unit as Leuze multiNet plus slave and as protocol converter: Technical Description
Manual44 pagesPDF 1.1 MB
Technical description of the Leuze MA 21 connector unit, a multiNet plus slave and RS 232 protocol converter for scanners and ID devices.
Covers · 1 model
The models it covers
Summary
What is in it
The technical description of the Leuze MA 21 modular connector unit, which links Leuze identification systems and hand-held scanners with an RS 232 interface to the Leuze multiNet plus network or directly to a host over RS 232, RS 422, RS 485 or TTY. It covers safety, specifications and functions, network addressing, controls and service mode, mounting, wiring the host, multiNet and power connections, commissioning with the BCL-Config software, parameter sets and resets, diagnostics, the type overview and maintenance.
Its parts
- General information
- Safety notices
- Specifications of the MA 21
- Mounting
- Connection
- Commissioning
- Diagnostics and troubleshooting
- Type overview and accessories
- Maintenance
From the manual
Key facts from this manual
Each line names its page in the PDF.
Leuze technical description for the MA 21 connector unit, which links RS 232 ident devices such as hand-held scanners to a host over RS 232, RS 422, RS 485 or TTY, or to the Leuze multiNet plus network. It covers specifications, wiring, setup with BCL-Config, parameter sets, resets and troubleshooting for the MA 21 100, 100.2, 110, 120 and 130.
- What it is
- Connector unit linking Leuze RS 232 ident devices (BCL 22, RFM 32, VR, hand-held scanners) to RS 422, TTY or multiNet p. 5
- Host interface
- MA 21 100: RS 485; MA 21 100.2: RS 485 multiNet plus with system connectors; MA 21 110: RS 232; MA 21 120: TTY; MA 21 130: RS 422 p. 22
- Power
- 18 … 36 V DC; max. 9 VA with IDS, max. 4 VA without p. 9
- Service interface
- RS 232, 9-pin Sub-D (male) inside the housing; fixed 9600 baud, 8 data bits, 1 stop bit, no parity, no handshake p. 17, 18
- Status LEDs
- RDY (power), ERR (error message), ACT (transparent mode), DTR (data transmission) p. 9
- External device power
- All but MA 21 100.2: 5.2 V DC ± 5 %, max. 0.8 A (terminals 30, 31) and 24 V DC (terminals 15, 16) p. 13, 28
- Client interface
- All but MA 21 100.2: RS 232 on terminals 26 to 28 (RXD, TXD, GND); no RTS/CTS handshake p. 28, 30
- Protocols
- All but MA 21 100.2: selectable data and frame formats, including 3964/RK512 p. 11
- Network addresses
- Master MA 30 at 00; slaves 01 to 30, numbered without gaps p. 12
- Cable length
- RS 232 host: up to 10 m; TTY: up to 1000 m; RS 422 and RS 485: up to 1200 m p. 23, 24, 25
- Network cable
- Shielded twisted pair, min. 0.2 mm2 (e.g. LiYCY 2 x 0.2 mm2); 220 Ω terminator on the last slave p. 26, 27
- Parameter sets
- Current (0), customer-specific (1) and factory (2); copied with commands PC01, PC10, PC20 p. 31, 32, 33
- Software
- BCL-Config or RF-Config, via the service interface p. 19
What this manual walks you through
- Wiring the host interface for RS 232, TTY, RS 422 or RS 485 p. 22, 23, 24, 25
- Switching the TTY interface between active and passive p. 24
- Wiring a multiNet plus network p. 26, 27
- Connecting the supply voltage and an external RS 232 device p. 27, 28
- Using the service interface and service DIP switch p. 17, 18, 19
- Setting the host and client interfaces in BCL-Config p. 29, 30
- Starting the MA 21 as a multiNet plus slave p. 31
- Managing and restoring parameter sets p. 31, 32, 33
- Performing a warm or cold reset p. 33
- Troubleshooting start-up and operating errors p. 35, 36
Good to know
- Switching to service mode interrupts the connection to the host computer. p. 18
- The 485 A and 485 B wires must never be swapped, or the multiNet will not work. p. 27
- In a multiNet network, leave the host interface settings unchanged; the MA 21 sets the multiNet protocol itself. p. 30
- A cold start replaces the current parameter set, so its settings are lost. p. 33
- PE must be connected because of the interference-suppression circuit. p. 16
Questions this manual answers
How do I reset the MA 21 to factory settings?
Hold the RESET button for more than 4 s for a cold start; DIP switch 2 decides whether the factory or customer-specific parameter set loads. p. 33
What should I do if the MA 21 RDY LED does not light?
Perform a software reset by pressing the RESET button for more than 0.2 and less than 4.0 s. p. 33
What are the MA 21 service port settings?
With DIP switch 3 set to Service, the port runs at 9600 baud, 8 data bits, 1 stop bit, no parity and no handshake. p. 18
Which MA 21 version connects to an RS 422 host?
The MA 21 130, which converts the RS 232 client interface to RS 422. p. 25
Why does the DTR LED flash but no data reach the host?
The host interface protocol may not match the host computer, or DIP switch 3 is set to Service instead of Host. p. 36
Contents
Chapters and sections
Each line opens the PDF at its page.
- MA 21 connector unit as Leuze multiNet plus slave and as protocol converter1
- 1 General information5
- 2 Safety notices7
- 3 Specifications of the MA 219
- 4 Mounting20
- 5 Connection22
- 6 Commissioning29
- 7 Diagnostics and troubleshooting35
- 8 Type overview and accessories37
- 9 Maintenance38
- 10 Appendix39
1 more line, from page 40 on
The whole text · 7 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file