Page 26
Leuze electronic
Installation
6
Installation
6.1
Storage, Transportation Attention! When transporting, package the device so that it is protected against collision and humidity. Optimal protection is achieved when using the original packaging. Heed the required environmental conditions specified in the technical data.
Unpacking • Check the packaging for any damage. If damage is found, notify the post office or shipping agent as well as the supplier. • Check the delivery contents using your order and the delivery papers: • delivered quantity • device type and model as indicated on the nameplate • Accessories • operating manual(s)
Figure 6.1:
Device nameplates MA 10 and BCL 80
• Save the original packaging in case the device must be stored or shipped at a later time. If you have any questions concerning your shipment, please contact your supplier or your local Leuze electronic sales office (see the last page of this operating manual). • Observe the applicable local regulations when disposing of the packaging materials.
Cleaning • Clean the glass window of the BCL 80 with a soft cloth before mounting. Remove any remaining packaging from the device such as cardboard fibres and Styrofoam balls, particularly in the area of the connector socket.
Attention! Do not use aggressive cleaning agents such as thinner or acetone for cleaning the device.
24
Technical Description BCL 80
Leuze electronic
Page 27
Leuze electronic 6.2
Installation
Mounting
6.2.1 Types of Mounting Accessories A wide range of mounting accessories are available for mounting the BCL 80 and MA 10 (Chapter 5 "Accessories / Order Designation").
BCL 80 without oscillating mirror add-on Mounting the BCL 80 There are two basic types of mounting arrangements for the BCL 80: • using the dovetail groove and the corresponding mounting accessories • using the fastening threads on the back- and underside of the devices (see Chapter 4.2 "Dimensioned drawings")
Figure 6.2:
TNT 35/7-24V
BT 56
Mounting example BCL 80 'stand alone'
Mounting BCL 80 and MA 10 You can fasten the scanner BCL 80 and connector unit MA 10 tightly together to form a single compact unit. • Plug the two devices together at the 15 pin SubD connector. Be sure that there is no dirt in the area of the seal (this guarantees an IP 65 protection class). Insert the two M4 x 30 screws included with the connector unit MA 10 into the countersunk drill holes on the bottom side of the MA 10, screw them into the corresponding threads in the BCL 80 and tighten them down. There are three basic mounting arrangements for the BCL 80 / MA 10 unit: • using the dovetail groove of the BCL 80 or the MA 10 and the corresponding mounting accessories • using the two upper fastening threads on the back side of the BCL 80 • using the four fastening threads on the underside of the MA 10 (see Chapter 4.2 "Dimensioned drawings")
Leuze electronic
Technical Description BCL 80
25
Page 28
Leuze electronic
Installation
Note! The cable screw glands of the MA 10 can be set either on the right or the left side of the unit. Loosen the four Phillips screws on the back side of the MA 10, carefully lift off the cover, replace it into the desired position and tighten down the four screws again. Be careful not to damage the ribbon cable.
BT 56
Figure 6.3:
Mounting example for the combined BCL 80 / MA 10 unit
Independent mounting BCL 80 / MA 10 Independent mounting of the BCL 80 and MA 10 is necessary when • the available mounting depth is not sufficient for both devices, e.g. is less than 85 mm, or • access to the mounting location of the scanner is difficult, but easy installation, commissioning and service are required, or • the operating status LEDs on the back side of the MA 10 must be easily seen.
BT 56
BT 56
Figure 6.4:
26
Mounting examples for the BCL 80 and MA 10 mounted independently
Technical Description BCL 80
Leuze electronic
Page 29
Leuze electronic
Installation
You can mount the individual devices in the following way as already described above: • using the dovetail groove of the BCL 80 or the MA 10 and the corresponding mounting accessories • using the fastening threads on the back- or underside of the devices • the connector unit can additionally be mounted using two M5 screws into the threaded holes that are otherwise used for fastening the BCL 80. The threaded holes have M5 threads
BCL 80 with oscillating mirror add-on For weight reasons, we do not recommend to mount the unit together with the MA 10. Always use a BT 58 when installing the BCL 80 with oscillating mirror.
BT 56
BT 58
6.3
BCL 80 with oscillating mirror and MA 10, mounted separately TNT 35/7-24V
Figure 6.5:
Proper Configuration of the Devices
Selecting a mounting location In order to select the right mounting location, several factors must be considered: • size, orientation, and position tolerance of the bar codes on the objects to be scanned • the reading field of the BCL 80 in relation to the bar-code module width • the resulting minimum and maximum reading distance from the respective reading field (see Chapter 4.3 "Optical Data") The best reading results with the line scanner are obtained when • • • • the bar code is moved along the reading window at an angle of approx. 9 … 15° the bars of the label are perpendicular to the scan line the reading distance lies in the middle area of the reading field high gloss labels or labels made from thermopaper are not used
Leuze electronic
Technical Description BCL 80
27
Page 30
Leuze electronic
Installation Best reading results with the oscillating mirror version are obtained if
• the unit is tilted downwards by 10 … 30° to avoid total reflections and to achieve the best depth of focus, or • it is rotated by 5 … 20° around its vertical axis.
Large depth of focus Due to the large reading distance and the large depth of focus, the BCL 80 is especially suited for applications with varying goods or reading distances. Examples are transport of pallets and packages, sorting and distribution applications. BCL 80 (oscillating mirror)
BCL 80
BCL 80 and MA 10
Depth: 170
Depth: 100
Depth: 100 + cabling space or rotation around vertical axis
171.5
Figure 6.6:
160 angle between bar code and reading window tilt angle of device
155
90
186
130
Minimum space requirements for installation
Note! The beam of the BCL 80 without oscillating mirror is emitted perpendicular to the housing’s lid. Therefore, you should mount the unit at an angle of 9 … 15° or move the labels past the housing at the same angle. When selecting a mounting location, pay attention to • maintaining the required environmental conditions (temperature, humidity) • possible soiling of the reading window due to liquids, abrasion by boxes, or packaging material residues • reducing the chance of damage to the scanner by mechanical collision or jammed parts
28
Technical Description BCL 80
Leuze electronic
Page 31
Leuze electronic
Installation
Application example: Packet conveyor belt BCL 80 Optical sensor
MA 10
Connection cable MA 10 / BCL 80 Voltage supply
Connection cable MA 10 / opt. sensor
Host interface Application example ’Packet conveyor belt’
Due to the great depth of focus, the BCL 80 is ideally suited for packet and pallet transportation applications.
6.4
Connection Attention! Connection of the device and maintenance work while under voltage must only be carried out by a qualified electrician.
If faults cannot be corrected, the device should be removed from operation and protected against possible use. Before connecting the device, be sure that the supply voltage agrees with the value printed on the nameplate. The power supply unit used to power the BCL 80 and MA 10 must have protected electrical separation by way of a safety transformer with double insulation according to DIN VDE 0551 (equivalent IEC 742). Be sure that the earthing conductor is connected correctly. Error-free operation is only guaranteed when the device is properly earthed.
Leuze electronic
Technical Description BCL 80
29
TNT 35/7-24V
Figure 6.7:
Page 32
Leuze electronic
Installation 6.4.1 Connecting the BCL 80 for ’Stand Alone’ Operation
If you would like to connect the BCL 80 for ’stand alone’ operation, you must make a corresponding connector cable with a 15 pin SubD plug (female) for the following connections: • power supply of 18 … 36 V DC, 5 W max. power • host RS 232 interface, or RS 485 when operating as a 'multiNet slave' • a sensor connection for triggering a read process RS 232 Terminal interface for commissioning and service
15 pin SubD female connector
Sensor connection (photoelec. sensor, key) for triggering a read process
Interface Host RS 485 / RS 232
Voltage supply 18 … 36 V DC Figure 6.8:
Connecting the BCL 80 'stand alone'
Attention! When using a normal 15 pin SubD plug, the device only has a protection class of IP 54 instead of IP 65! Therefore, use the original Leuze cable from the accessories list. These cables are fitted with a seal so that protection class IP 65 is maintained. Switching inputs A read process can be triggered by applying a voltage of 12 … 36 V DC to the switched input connections 'Sensor 1A' and 'Sensor 1B'. The switched input maintains an electrical separation of up to max. 250 V.
30
Technical Description BCL 80
Leuze electronic
Page 33
Leuze electronic
Installation
1 2 3 4 5 6 7 8
GND Sensor 1A CTS (Host) RTS (Host) TXD Service MODE_F reserved V_IN
9 Sensor 1B 10 NC 11 RXD (Host) 12 TXD (Host) 13 RXD Service 14 MODE_S 15 GND_IN
15 pin SubD type connector (male) Insert a resistor R = 220 Ω / 0.25 W here, if the device is the last subscriber on the RS 485 data line. Do not use a resistor, if the RS 485 line continues.
Operating mode
4 leave open
Connection diagram for the SubD connector plug
TNT 35/7-24V
Figure 6.9:
bridge
Wiring description Pin 1 Pin 2 Pin 3 Pin 4 Pin 5
GND Sensor 1A CTS (Host) RTS (Host) TXD service
Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Pin 11 Pin 12 Pin 13
MODE_F Reserved, V_IN Sensor 1B NC RXD (Host) TXD (Host) RXD service
Pin 14 Pin 15
MODE_S GND_IN
Leuze electronic
0 V signal reference potential (RS 232 / RS 485) switched input 1A, 12 … 36 V DC, see fig. 6.18 and 6.19 for wiring CTS signal, host interface RS 232 / RS 485 B RTS signal, host interface RS 232 / RS 485 B used when MA 10 is connected / without MA 10: service interface, standard protocol RS 232: open; RS 485: connect with MODE_S must not be used supply voltage + 18 … 36 V DC switched input 1B, 12 … 36 V DC, see fig. 6.18 and 6.19 for wiring not used RXD signal, host interface RS 232 / RS 485 A TXD signal, host interface RS 232 / RS 485 A used when MA 10 is connected / without MA 10: service interface, standard protocol RS 232: open; RS 485: connect with MODE_F Supply voltage 0 V DC
Technical Description BCL 80
31