Page 41

INTEGRA 9100 / 9100Q VERSION 4.28

Applications and Guidelines – continued 2. What size bar code can I grade? A. Width Bar code symbols vary in width. A formula called the “BAR ELEMENT RESOLUTION” (BER) is used to determine if the bar code symbol is too wide to be verified by an INTEGRA 9100 / 9100Q. The BER should be less than 200. The formula for BER is as follows :

BER

= WIDTH OF BAR CODE (in) or (mm) NARROW BAR WIDTH (in) or (mm)

Example of a bar code symbol which can not be verified by the INTEGRA 9100 / 9100Q : 3.5 in 88.9 mm 3.5in = 500BER .007in

NO 88.9mm = 500BER 0.178mm

.007 in/(0.178 mm)

Example of a bar code symbol which can be verified by the INTEGRA 9000 / 9000Q : 1.5 in 38.1 mm 1.5in = 75BER .02 in OK 38.1mm =75 BER 0.51mm

.02 in/ (0.51mm)

B. Height: If the height of the bars in your bar code is .25in/ (6.35 mm) or less, the INTEGRA 9100 / 9100Q may not be able to provide an accurate ISO/IEC/ANSI grade.

- 41 -

Page 42

INTEGRA 9100 / 9100Q VERSION 4.28

Applications and Guidelines – continued 3. How far can the system controller be from the readhead(s)? The maximum cable length cannot exceed 25ft/ (13m) 4. How does the INTEGRA 9100 / 9100Q know when the bar code is in the camera’s field of view? The INTEGRA 9100 / 9100Q must be ‘told’ that a bar code is in the field of view. You must provide a consistent registration mark. Various types of equipment can be used to detect the registration mark, they include ‘through the web sensors’, ‘reflective sensors’, ‘a proximity switch’, or a computer generated signal. You must decide which method is best for your application. (SEE CHAPTER ON REGISTRATION MARK TRIGGER) 5. How does the INTEGRA 9100 / 9100Q ‘see’ the bar code when it is moving at high speeds? A. Web Direction Bar codes in motion can be horizontally or vertically inserted in the ‘field of view’. A strobe unit is used to eliminate the effects of motion. It is important that ambient light is controlled so that it does not over power the strobe light. B. Orientation The bar codes on the web may be in a picket fence or ladder orientation. However the read head must be positioned so that the bar code appears on the monitor to be in a picket fence orientation. The bar code must be perpendicular in the field of view.

- 42 -

Page 43

INTEGRA 9100 / 9100Q VERSION 4.28

Applications and Guidelines – continued C. Bounce At times the vibration of the web will cause the bar code to ‘bounce’ up and down. ‘Bounce’ changes the distance from the camera lens to the surface of the bar code, or ‘depth of focus’. Changes in the depth of focus may result in variations in the ISO/CEN/ANSI grade of the bar code symbol. It is mandatory that this bounce deviation does not exceed a + or - .125 in (3.175mm). 7. Does the web have to be flat? As the bar code passes under the readhead it is important that it be flat and parallel to the readhead. If one side of the code is closer to the readhead, or a portion of the bar code is curved it will change the depth of focus. Changes in the depth of focus may result in variations in the ISO/CEN/ANSI grade of the bar code symbol. 8. How will the label stock affect the ISO/IEC grading? A. Reflectivity If your label stock is highly reflective, the position of your read head must be positioned so that the strobe light does not create a ‘hot spot’ or reflection on the bar code surface. B. Opacity You must take into consideration the opacity of the label stock. If you can ‘see through’ the label stock, a background plate may need to be installed, which is designed to be a color consistent with the intended final use of the bar code. 9. If I do not meet the guidelines can I still use the INTEGRA 9100 / 9100Q? Maybe. It is our recommendation that actual production samples be tested as part of the decision process to determine if the INTEGRA 9100 / 9100Q can be used in your application. 10. The Final INTEGRA-9100 grade. What does it tell you? The INTEGRA 9100 / 9100Q gives you an overall ISO/CEN/ANSI grade out. It does not report what part of the specifications is wrong. An off- line certified verifier needs to be used to establish what is wrong.

- 43 -

Page 44

INTEGRA 9100 / 9100Q VERSION 4.28

Applications and Guidelines – continued 11. Why does the INTEGRA-9100 grade Spots and Voids differently? According to the standards, spots and voids are measured as a ratio between the deviation of non-uniformity found within bars / spaces, and symbol contrast. It is stated as a measurement of signal amplitude as evaluated within the Scan Reflectance Profile (SRP). Any non-uniformity mark which decreases the symbol contrast within a bar or space element by 30% is considered to be an “F GRADE DEFECT”. Here are some problems encountered when using these rules: Problem A: The Primary Calibration Standard labels for Spots and Voids created by Applied Ima ge are made by drawing an “error line” through a bar or through a space vertically. This was done in order for a wand or laser to “see” the blemish on all scans. But, it is not a true representation of a Spot or Void. It is a streak. A very narrow streak. The Primary Calibration Standard label made by Applied Image for an A to F GRADE Spot/ Void’s inserts this “error line” vertically. For an F GRADE label, this “error line” measures 20 microns in width. This is less than the width of a human hair. In inches this is equal to .0008 “ wide. When a verifier scans over this small of a line, it sees only a slight reduction or addition in contrast. Normal scanners used in the retail market cannot see this small of an error. Problem B: The sample bar code images below demonstrate yet another problem with other verifiers. Both of these examples are A GRADE labels according to the ISO/IEC Standards. This is because a verifier cannot see these two-dimensional “real” spots and voids.

Both examples of spots and voids are detected by the INTEGRA-9100. Typical verifiers using the ISO/IEC Standards cannot detect these types of errors.

The INTEGRA-9100 verification system is designed to grade every .006 inch of bar height. The blemishes and streaks represented above would be detected and reported as an error. This goes against the Standards. Label Vision Systems, Inc., however, believe that this is a better way to detect Spots and Voids.

- 44 -

Page 45

INTEGRA 9100 / 9100Q VERSION 4.28

Applications and Guidelines – continued 12. The INTEGRA-9100 uses a white light source. How can it verify correctly? The ISO/ANSI standards state that the wavelength of a diffuse light source mus t be suited to the intended scanning environment. The INTEGRA-9100 will use a DC Fluorescent white light source or a xenon strobe white light along with the addition of a Wratten 26 red filter when necessary. Each customer will be different depending on their needs. According to the ISO/IEC Standards, using a Wratten 26 red filter with a white light source is an acceptable way to correlate to the Standards. Verification equipment needs to be certified according to the ISO/CEN/ANSI standards. There is a company located in Rochester, New York where a set of black and white Primary Calibration Standards for UPC/EAN symbols can be purchased. This set of standards will certify whether a verifier is calibrated correctly and would therefore be recognized by ANSI, UCC, and NIST. But this is only for symbols made of black bars and white background. They do not have a set of standards for various color combinations. According to the standards, the best color combination for maximum contrast is black bars on a white background. Other color combinations can be used providing the bars are black, blue, or green and the background is white, red, or yellow. These color combinations were created because most scanners and verifiers cannot detect anything printed in red. The INTEGRA 9100 / 9100Q can and will detect the color of red. This means that a bar code label which uses red bars on a black background can be graded with this system. Other verifiers may not be able to detect the red bars.

- 45 -

Page 46

INTEGRA 9100 / 9100Q VERSION 4.28

Static and Dynamic Bar Code Verifier Conformance Specifications INTRODUCTION

Printed bar code quality was first addressed by the Uniform Code Council (UCC) using UPC symbols. Then in 1990 the American National Standard Institute (ANSI) published the first manual for Bar Code Print Quality (ANSI X3.182-1990). This document outlines the parameters of bar code print quality based upon the optics of a bar code scanning system. These parameters were now to be tested with respect to the analog electronic signal generated by the optical image detector found within all scanners. This analog electronic signal was now to be called a Scan Reflectance Profile (SRP). Grade quality for any given label would now be based upon formulas surrounding the SRP. ANSI updated their document in 1995. At the same time, the Committee for European Normalization (CEN) and the International Standards Organizations (ISO) published their version of printed bar code quality. (Document number: EN 1635) In the year 2000, ANSI, CEN, and ISO decid ed to publish one document designed to unify all bar code verifier conformance specifications throughout the world. The document number is: ISO/IEC 15416:2000(E). This document titled “Bar Code Verifier Conformance Specifications” is how the INTEGRA-9100 is certified and is recognized by UCC, AIAG, HIBCC, and EAN. Part of the Bar Code Verifier Conformance Specifications titled: INTERNATIONAL STANDARD ISO/IEC 15426-1:2000(E) Part 1: Section 2 titled “Conformance” states the following: The instrument shall be considered to conform with this part of ISO/IEC 15426 if it performs the functions defined in 6.3 and if the results of measurements of primary reference test symbols carried out in accordance with clause 8 meet the following conditions: a) the measured overall symbol grade, to one decimal place, is within +/- 0,2 of the overall symbol grade declaired by the supplier of the primary reference test symbol, and b) the arithmetic means of the ten measurements of individual reported parameters are within the tolerances shown in Table 1 below, and

- 46 -

Page 47

INTEGRA 9100 / 9100Q VERSION 4.28 continued c) the ten measured grades for the individual reported parameters, rounded to the nearest whole number, are the same as the grade declaired by the supplier of the primary reference test symbol.

Table 1 Parameter

Tolerance

Rmax

+/- 5% reflectance

Rmin

+/- 3% reflectance

Decodability

+/- 0,08

Defects

+/- 0,08

NOTE: The tolerances are additional to any tolerances stasted by the supplier of the primary reference test symbols.

Section 6.3 Mandatory functions A bar code verifier, in accordance with ISO/IEC 15416, shall be capable of: _collecting reflectance measurements from points along one or more scan paths across a bar code symbol: _establishing a scan reflectance profile from these measurements: _analyze the scan reflectance profile; _reporting individual scan reflectance profile parameter grades; _determining and reporting overall symbol grade (including aperture diameter and peak wave length of light used; _reporting the decoded data; _reporting all encoded symbol characters. The method of reporting is not specified but may be by means of, for example, a display screen in the instrument, a printed report, or electronic communication with another device such as a computer. End of quoted section - 47 -

Page 48

INTEGRA 9100 / 9100Q VERSION 4.28

SCANS PER LABEL AND LABEL ORIENTATION: The INTEGRA-9100 scans a 100% UPC bar code symbol around 145 times, static or dynamic, ladder or picket fence orientation, creating a Scan Reflectance Profile for each of the 145 scan lines. The standards state that at least 10 scans are required.

OVERALL SYMBOL GRADE AVERAGE: The INTEGRA-9100 does not report individual parameter grades. It reports the overall symbol grade average only. An external verifier is required to evaluate why the grade is low. When reporting the overall grade average, the ISO/IEC standards will round off that number to the nearest whole number. The INTEGRA-9000 will not do this. It will report the overall grade out to one decimal point. This is done so the operator can measure the difference between a low value within a grade and a high value within that same grade. In other words, it will report a low B GRADE as a 2.6 and a high B grade as a 3.4. The ISO/IEC standards would report both of these grades as a 3.0 B GRADE.

STATIC verses. DYNAMIC VERIFICATION

There are two kinds of verifiers, static and dynamic. A “static” verifier is one that is used to verify the quality of a bar code symbol which is no t in motion. In other words, it is being checked “off- line”. A “dynamic” verifier is one that is used to verify the quality of a bar code symbol while it is in motion or “on- line”. The INTEGRA-9100 is a dynamic verification system. It is used to check the quality of bar code symbols as they are being printed. Speeds greater than 1000 feet per minute have been achieved. It is capable of grading 480 different bar code symbols per second in any orientation. A “real-time” (See Figure: 1) graph is displa yed on a computer monitor that gives the operator full knowledge of over-all grade quality as they are being printed. If and when the printing process begins to deviate in quality, the INTEGRA-9100 reports this trend as it happens. The operator can then make an adjustment to the printing process…...correct the problem….and continue to print quality labels…...with little or no “downtime”. The INTEGRA-9100 software does not recognize motion. Bar code label images are collected as a whole. The number of scans it uses to determine a grade depends on the height of bar code. A typical 100% UPC label will be scanned 150 times at any speed and in any orientation providing the bars of the code are perpendicular to the field of view. Every .006” of bar height is checked for quality. This system identifies the quality of labels in motion as if it was being done “statically”. - 48 -

Page 49

INTEGRA 9100 / 9100Q VERSION 4.28

LIGHT SOURCE and APERTURE Vision based systems use a diffuse light source and then use an array of tightly spaced horizontal pixels mounted on a chip (CCD CHIP) to examine the reflected image. And, with vision, the aperture is called by a different name. It is called the iris. The iris controls the amount of light entering the CCD chip. The iris must be adjusted according to a Contrast Calibration Label supplied with the system. This teaches the INTEGRA-9100 system to correlate light intensity to the established Standards according to the measured bar width. This aperture adjustment is done manually during the SETUP of all jobs. The ISO/ANSI standards state that the wavelength of a diffuse light source must be suited to the intended scanning environment. The INTEGRA-9100 will use a DC Fluorescent white light source, a xenon strobe white light, with a Wratten 26 red filter. Each customer will be different depending on their needs. A xenon strobe is used to eliminate the effects of motion for high speed applications which might exceed 300 feet per minute. A DC Fluorescent light source is used in applications where the web speed is less than 300 feet per minute.

The SCAN REFLECTANCE PROFILE

The bar code image is focused on the video camera's array of horizontal pixels. These small pixels (12 microns square) create a string of DC levels that represent the bars and spaces of the bar code image. Wand based systems would call this string of data a Scan Reflectance Profile (SRP). In the world of vision it is called a Video Signal Profile (VSP). The SRP and the VSP are the same thing. The video camera should have a horizontal pixel count greater than 760 pixels in order to obtain data resolute enough to measure high density bar code labels. With a camera, lens, and linear light source, a VSP is generated for every .006 inch of bar height. The VSP is then sent to the microprocessor for decoding. With vision, the actual xdimension (smallest bar width in a bar code image) for a given label does not really change. By using different lenses a 2 mil label is no different than a 20 mil label. Since laser based systems are limited in their resolution, certain attention must be given to the measured xdimension with respect to the resolution of the intended scanning environment. In other words, the INTEGRA-9100 system can correlate any size bar width label, but that doesn’t mean the intended reading device has the resolution capable of seeing it. The SRP is what all verification software uses to inspect quality. With a wand based system, the SRP is obtained by moving the wand (called scanning) somewhat quickly through the bar and spaces of the bar code image. This presents many challenges to operators who are trying to understand bar code quality since no two scans are alike. No - 49 -

Page 50

INTEGRA 9100 / 9100Q VERSION 4.28 two operators will scan the same. Too fast, too slow, too much of an angle, or too much of a jerky motion are some of many problems associated with wand based verification. It is also impossible for a wand based verifier to scan bar code labels as it would be scanned at the grocery store. Nearly all retail stores now use vision (CCD) or laser technology. With the addition of two-dimensional coding, verifiers of the future will all be vision based. A Scan Reflectance Profile (SRP) can be represented as an X-Y graph. X would represent a measurement of time while Y would represent the amplitude of reflected light. Points and distances along the X-axis are completely relative. The Y-axis of the SRP is a measurement of reflectivity. A wand based system will measure the highest possible point (white) as 100% reflectivity. The lowest possible point is 0% reflectivity (black). The points and distances along the Y-axis are absolute, not relative. ISO/ANSI established the following list of measurements to determine bar code symbol quality. Next to the measurement indicates which axis (X-Y chart) of the Scan Reflectance Profile is being measured. 1. Edge determination 2. Reflectance minimum (Y-axis) 3. Edge contrast minimum (Y-axis) 4. Symbol contrast (Y-axis) 5. Modulation (Y-axis) 6. Defects (Y-axis) 7. Decodability (X-axis) 8. Decode 9. Overall grade EDGE DETERMINATION The ISO/ANSI formula for Edge Determination is directly related to the placement of the Global Threshold. The Global Threshold (GT) is defined as a DC voltage level positioned on a SRP or a VSP half way between the highest reflectance DC level and the lowest reflectance DC level. Software for the INTEGRA-9000 modulates the GT in order to establish an absolute level of reflectance. We call this a Managed Global Threshold (MGT) and is the heartbeat of the LVS system. MGT is better explained later. The Global Threshold is placed at a DC position to this formula. GT = Rmin + SC/2 If the GT is at this position and the bar code label image meets the decodability requirements then it is decodable and considered to PASS the Edge Determination test. Software evaluates Edge Determination every .006 inch of bar height

- 50 -