The text of a manual · part 4 of 7
INTEGRA 9100 Operator's Manual, pages 31 to 40
Pages 31 to 40 of 70
The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Label Vision LNT-92A
Page 31
INTEGRA 9100 / 9100Q VERSION 4.28
SCREEN FUNCTIONS
This is referring to the message length of the encoded bar code data. When checked, software will report an error for any detected bar code which does not contain the same number of digits as originally set up for that specific job.
Mismatch: There is a box on the Alarms screen titled “Sequencing”. When “Fixed” is chosen, the operator will type in a number into the Sequence box (4). This teaches software to accept all bar codes containing the same message. If any other character string is detected a “mismatch” error will be reported.
Sequence: Bar code can be sequentially checked. The ascending or the descending box needs to be selected.
4
8
5 6
Reading columns or rows of symbols might cause a natural sequence order to jump by a set number of digits. This can be arranged by selecting “delta” (6). A range of numbers is presented to you. Choose the right delta sequence number. The operator also has the ability to check all numeric-alpha sequences from base 10 to base 36. A green background box (7) indicates which character is part of the sequence. Software also allows the operator to create any base numbering system by clicking the base 36 button, then
7
Sequencing box
“remove” or “add” characters as required. Typically, operators will choose to remove vowels from the character string. Remember that this is only for numeric/alpha sequences. It will not work for alpha/numeric. Up to 4 “Check digits” (8) can be turned off so as to not interfere with sequential checking. Inside the Sequence area is a box called Variable. This box must be checked if the job calls for labels that are neither fixed nor sequential. Failure to do so will cause the system to report eve ry different label as an error.
Range: Some jobs require that there are no duplicates within a set of bar codes. Range checking performs this function. (See Section 1.5.) Basically, software will check the bar code numbers of a “run” to make sure it was never duplicated within that specific “job”. (A “job” is made up of many “runs”.) This data is then archived in a “range” format. - 31 -
Page 32
INTEGRA 9100 / 9100Q VERSION 4.28
SCREEN FUNCTIONS
Software will remember the first and the last number of all “runs”. Software will then check new “runs” within a “job” against these stored ranges.
Some jobs require the operator to create “sets” of numbers. And, at the same time, not allow any duplicates between the “sets”. This is allowed by locating the “Repeat ” number box within the Sequencing section and selecting a number equal to how many times a specific bar code number is to be repeated within a “set”. Duplicating checking with Checksum: Repeat numbers. Checksum is a mathematical trick added to a bar code data string whose value is used to check the validity of the bar code data. From 1 to 4 digits are added to the original bar code data. There are various routines on the market. The Check digit routines supported by the INTEGRA-9100 are Modulus 11, and 3131. If the operator checked this box on the Alarm matrix, then an alarm will be activated if the checksum does not add up correctly. Located on the Job Screen Grade Error: To the left of the Grade Error row is a software dial which allows the operator to preselect when to activate a grade error signal. These levels are according to the ISO/IEC standards. Also, trends in grade quality are displayed as a histogram on the Operate Screen. This means that the operator can observe trends in grade quality as it is being printed.
Blemish Error: Each bar code symbol is checked every .006 inch (.15mm) for bar height. A spot, void, or blemish greater than .006 inch of bar height will be deducted from the expected total bar height. This is reported to the operator as a percent of failure. The percent of blemish error detection can be entered from 5% to 95%. Factory default is set to 50%.
Also, blemish trends are displayed as a histogram on the Operate Screen.
- 32 -
Page 33
INTEGRA 9100 / 9100Q VERSION 4.28
SCREEN FUNCTIONS
Growth error: Various methods of printing bar code symbols can create uneven widths of bars and spaces due to uneven print plate pressure or deviations in ink viscosity. The industry standard for bar growth tolerances is 75% and 125%. To the left of the Grade Error row is a software dial that allows the operator to pre-select when to activate a bar growth error signal. Bar growth and shrinkage trends are also displayed as a histogram on the Operate Screen.
Grade warning: To the left of the Grade warning row is a software dial that allows the operator to preselect when to activate a grade warning signal. This feature is one of the most important features of this system. Properly set, software will warn the operator when the quality of the bar code is slipping. The operator can then adjust his printing process to improve on the grade quality often without the need to stop the printing process. Trends in grade quality for Contrast, Modulation, Decodability, are displayed as a histogram on the Operate Screen. This means that the operator can observe trends in grade quality as it is being printed.
Blemish warning: Each bar code symbol is checked every .006 inch (.15mm) for bar height. A spot, void, or blemish greater than .006 inch of bar height will be deducted from the expected total bar height. This is reported to the operator as a percent of failure. The percent of allowable blemish detection can be entered from 5% to 95%. Factory default is set to 50%. Also, blemish trends are displayed as a histogram on the Operate Screen. - 33 -
Page 34
INTEGRA 9100 / 9100Q VERSION 4.28
SCREEN FUNCTIONS
Growth warning: Various methods of printing bar code symbols can create uneven widths of bars and spaces due to uneven print plate pressure or deviations in ink viscosity. The industry standard for bar growth tolerances is 75% and 125%. To the left of the Grade warning row is a software dial that allows the operator to pre-select when to activate a grade warning signal. Bar growth and shrinkage trends are displayed as a histogram on the Operate Screen. Good read: The Good read signal is not an error condition. It is used to give the operator an indication when a bar code label has passed the verification test. Typically, it is set up to activate the green light tower.
3.3.0
Output signal timing.
At the bottom of the Alarm matrix are some boxes marked Consecutive errors, Gate delay, and Dwell time :
Bottom of Alarm matrix
Consecutive errors: An operator may not wish to activate STOP MOTION when a single error occurs. This box allows the operator to set up a certain number of consecutive errors before an error condition will activate a relay.
Gate delay: This feature allows the operator to activate a parts kicker, error marker, or STOP MOTION at a different position along the path of the label matrix. Since “errors” are reported immediately, this feature allows the operator to delay the error signal until the label reaches a specific lo cation. The distance between the beginning of a label and the beginning the very next label is called the “label repeat”. One Gate delay is equal to this distance.
Dwell time: When software detects an error condition, it reports the error to the Light Tower Interface Unit. The Dwell time allows the operator to set the amount of time the error condition is allowed to stay “on”. Four different “on” times are available: .02 sec. .1 sec., 1.0 sec., 5.0 sec., and “hold”. When the “hold” dwell time is chosen, the operator must push the “clear” button (3) that is located at the top of every screen.
- 34 -
Page 35
INTEGRA 9100 / 9100Q VERSION 4.28
SCREEN FUNCTIONS
Operate Function Screen 2 3
5 6
7 1 4
4.0
Operate screen
There are several functions on the Operate screen. At the bottom right is a Start / Pause button (1). The Start button is color green. Once the Start button is pushed, it will change to a yellow color and will be titled Pause. The Start button is used to begin the dynamic verification process. This is called a “run”. The Pause button is used to pause a “run”. There is no reporting while the system is “paused”. This feature is used when the operator needs to stop the press or rewinder to make adjustments. Once the adjustments are made, the same “run” is continued. There is no gap in the reporting process. The Stop button is used to stop a “run”. In contrast to the Pause feature, pushing the Stop button will cause software to end that “run” and report the results. If the operator starts again, software will begin collect data within a new “run”. At the top of the Operate screen is a clear alarms button. (2) When any alarm matrix function is placed into the “hold” position, this button will clear the alarm being held. The Overall ISO/IEC grade is displayed in the Label text window next to the decoded data (7). - 35 -
Page 36
INTEGRA 9100 / 9100Q VERSION 4.28
4.1
SCREEN FUNCTIONS
Real-time histograms
There are up to 8 lanes of bar code data at the top of the Operate screen. The yellow box (3) surrounding one of the 8 lanes is an indication of which lane is being displayed at the bottom of the screen. The five histograms will show contrast, modulation, decodability, blemish, and bar growth for every label within the selected lane.
ISO grade
Each lane at the top of the Operate screen will show grade quality, level of blemishes, and a bar growth indicator super imposed on top of each other.
Blemish
Bar growth
4.2 Additional information There are 3 small boxes on the bottom right (6) for indicating Labels per second, Press speed and number of Errors within the current “run”. While in the operate mode, software will allow the operator to visit the Reports Screen without interfering with incoming data. No other screen is accessible during a “run”. The video display (5) will also show a visual picture as seen by the read head for the selected lane.
3
5 6
- 36 -
Page 37
INTEGRA 9100 / 9100Q VERSION 4.28
SCREEN FUNCTIONS
Reports Function Screen
1
2
5.0
Reports screen
The Reports screen is a visual collection of all data analyzed by the system for one “run” within a “job”. A “job” can have up to 50 different “runs”. Each “run” has a start time and a stop time indicated. (1). The Reports screen can be accessed during a “run”. The Report screen will visually display bar code quality as well as all reported errors (2) for any individual lane or show all lanes collectively.
5.1
Viewing or printing a “run”.
At the bottom of the Reports Screen is a series of buttons used to activate specific features as defined here: Previous run: This allows the operator to view the log for any of the previous “runs” within that “job”. Next run: While viewing a previous “run”, this allows the operator to toggle to the next “run”. Delete run: This allows the operator to delete a specific “run”. - 37 -
Page 38
INTEGRA 9100 / 9100Q VERSION 4.28
SCREEN FUNCTIONS
Summary, Log, Errors: When any of these three boxes are activated, a pop- up menu will be displayed. They will look like this:
The operator can then choose an action. They can view a summary report, a log report, or an errors only report. Or, they can choose to save a summary, or a log, or errors only to a floppy or CD. All systems come with a Read/write CD burner. When the operator requires a report to be saved to a CD, the following pop- up window will be displayed:
Press the appropriate task required.
- 38 -
Page 39
INTEGRA 9100 / 9100Q VERSION 4.28
5.2
SCREEN FUNCTIONS
Reports
This is what a typical report looks like for one lane.
Error code ISO/IEC grade Gate number
Bar code data Date Time
The report will list each row of bar code labels with a “gate” number. Next to that is the date when data was collected followed by the time of day. Next is the encoded bar code data followed by the ISO/IEC verification grade. Finally, printed after the verification grade is a two-digit error code. When an error is detected a two-digit code is listed according to the Output matrix listed on the Alarm screen. Only one error condition is reported in a hierarchy. The top error condition (missing labels) has the highest priority.
- 39 -
Page 40
INTEGRA 9100 / 9100Q VERSION 4.28
APPLICATIONS AND GUIDELINES Here are a few questions you need to ask yourself when determining if an INTEGRA 9100 / 9100Q will work in your application. 1.
How fast can I go?
A. Frequency of labels The INTEGRA 9100 / 9100Q systems verify up to 30 bar codes per second per lane. B. Web Speed The following formula will enable you to determine your maximum web speed for a given job. BAR CODE REPEAT (in) x 300 = F/M (FEET per minute)
Example of Label Repeat:
1 in 25.4mm 1.5 in 38.1 mm
1 in x 300=300 FPM 25.4 x 3.63 = 92.2 MPM
1.5 in x 300=450FPM 38.1 x 3.63 = 138.3 MPM
- 40 -