Page 21

INTEGRA 9100 / 9100Q VERSION 4.28

SCREEN FUNCTIONS line of the description box (6) is displayed on all screens. Data critical to a given job should be entered on the first line.

1.6 Read head detection or lanes to use The read head (8) indicator is designed to display a check ma rk for every read head you have selected. Each lane has a specific channel number. The operator must choose which lanes are to be used by clicking on the individual boxes.

1.7

Range checking (Duplicate checking)

To enable Range checking, the operator must select from a drop-down list. The list will appear on the JOB SCREEN, and will be labeled Range error on the Alarm Screen. The choices will be, “Off”, “Individual lanes”, and “All lanes”. If the operator selects “Individual lanes”, then each lane is checked independently of all others. In other words, a label may appear in lane 1, and then appear in lane 3 at some other time. If the operator selects “All lanes”, then a label may only appear once during the life of the job. Selecting either “Individual lanes or “All lanes” enables the “range error checking” feature. When enabled, the computer will maintain an archive file for that job. The archive file will contain one line for each lane for each run. This file will be unlimited in length. It will not be subject to the 50-run limit all other jobs have. Each line will contain the date, time, lane number, the smallest label in the range, and the largest label in the range. Here is an example of an archive file. (The examples will show numbers incrementing by 1. It is important to understand that this feature will work equally well for decrementing numbers, or if the offset is a value other than 1.)

EXAMPLE ARCHIVE FILE Date

Time

Gate Lane 1

09/06/1999 09/06/1999 09/06/1999 09/06/1999 09/07/1999 09/07/1999 09/07/1999 09/07/1999

11:01am 1 11:01am 2 11:01am 3 11:01am 4 2:36pm 1 2:36pm 2 2:36pm 3 2:36pm 4

100001 200001 300001 400001 170001 270001 370001 470001

Lane 2 152183 252183 352183 452183 199777 299777 399777 499777

- 21 -

Page 22

INTEGRA 9100 / 9100Q VERSION 4.28

SCREEN FUNCTIONS

When the operator pushes the Start Button to begin a run, the computer will check to see if the Range checking is enabled. If it is, software will then check to make sure the operator also selected “Ascending” or “Descending”. If the operator selected either “Fixed” or “Variable”, then the run will not start and the following error message will be displayed:

Range checking has been enabled. This requires either Ascending or Descending.

If Range checking is enabled, then software will perform ext ra processing after reading the first row of labels. If “All lanes” was selected (instead of “Individual lanes”), and if a label appears in more than one lane, the operator will be warned:

Label ##########appeared in more than one lane.

If all of the labels are unique, or if the operator selected “Individual lanes”, the computer then checks that none of them fall within a range listed in the archive file. If the operator selected “Individual lanes”, then only those ranges for the same lane are checked. If the operator selected “All lanes”, then all lanes are checked. If a label falls within a previous range, then the following message is displayed:

Label #### overlaps #### - #### that was used on date / time.

If a range error is detected in the first row of labels, then all labels in that lane (or lanes) will be flagged as a range error for the remainder of the run. These errors will continue until the operator stops the job and corrects the problem. If no range errors are found, software is trained to use the archive file to determine which range comes before the label read, and which range comes after the label read. These two ranges determine the acceptable range for that lane. For example, suppose the operator selected “All lanes” and the following labels were read as the first row: 160001 260001 360001 460001

Using the EXAMPLE ARCHIVE FILE as listed at the beginning of this section, lane 1’s range is from 152184 to 200000, lane 2’s range is from 252184 to 3000000, and so on.

- 22 -

Page 23

INTEGRA 9100 / 9100Q VERSION 4.28

SCREEN FUNCTIONS

Not only must software scan the archive file, but it must use all of the labels in the first row as well. This is necessary in order to catch duplicates from one row to another. During a run, any type of Range error will continue to be flagged and reported indefinitely. This is because software determined the limits at the beginning of the run. There is insufficient processing available to re-compute this information after each label. Here is an example that illustrates this. The archive file would contain the following: 09/07/1999

5:10pm 1

200 299

The operator then begins the following run of labels:

100 101 102 103 Etc.

When 200 is read, a sequence error will be reported. In fact, labels 200 through 299 all will generate sequence errors. In fact, 300 and higher will also generate sequence errors. This is because, after the first row, software determined that the upper limit for lane 1 was 200. That is all it knows. Since 300 is beyond 200, it is an error. When a run is stopped, software will record the smallest and the largest label for each lane in the archive file. Any labels between the smallest and the largest label that were not included in the run will no longer be available for that job. Range checking assumes that a standard ASCII order is used. In other words, 0 through 9 precede A through Z. If Range Checking is selected, then a new button will appear on the job screen. This button will be labeled “Override Archive”. When activated, the archive file will be shown on the screen. The operator will be able to double-click on any line to disable that line (and all other lines for the same date and time) from being included in the override checking. There will be an area for the operator to enter a comment as to why the run should be ignored. The default value will be “No Reason Given”. A button will also appear allowing the operator to manually add new ranges to the archive file. This makes it possible to exclude ranges that were run prior to enabling this feature. Another button that will appear on the JOB SCREEN is “Query Archive”. Pressing this button allows the operator to test a number against the archive file. If an overlap is detected, the following message is displayed: Label #### overlaps #### - #### that was used on date / time.

The operator may choose to use this feature on every lane prior to starting the press, rather than wait for the Integra to flag an error on the first row. - 23 -

Page 24

INTEGRA 9100 / 9100Q VERSION 4.28

SCREEN FUNCTIONS

SETUP FUNCTION SCREEN

1

3

4 2

2.0

10

Setup screen

The Setup Screen is used to teach software what type of symbol and what parameters are being presented to the read head. All calibration functions are accomplished on the Setup Screen.

2.1 Video monitor A bar code label is placed into the read head’s field of view and can be seen in the Video monitor box. (1) Double clicking anywhere inside the Video monitor box (1) will cause the bar code image to magnify to a full screen display. Double clicking again anywhere on the magnified image will return it to the original size.

2.2 Multilane selection The box marked “Multilane Selection” (3) gives the operator an indication of which lane is being viewed. A “dot” under a specific lane number 1 thru 8 indicates which lane is in View.

- 24 -

Page 25

INTEGRA 9100 / 9100Q VERSION 4.28

SCREEN FUNCTIONS

2.3 Trigger In order to evaluate the quality of a bar code video image in motion, the photo eye must send software a signal which indicates that a bar code label is present or within the camera’s “field of view”.(10) The Traffic light located in the Trigger box will turn green when the photo eye is aligned properly to the video image. The Trigger box has two choices (2) “Normal ” and “Test”. Choosing “Test ” will allow the read head to fire at 10LPS (labels per second). This will allow the operator to see a live video bar code image within the Video monitor box. (1).

2.4 System Calibration Calibration is used to ensure correlation to the ISO/IEC standards. It is based on the Certified Contrast Calibration label, which is located in the back of this manual. The calibration label is coded to work with this software. No other bar code label can be used. The following is a step-by-step method of how to calibrate. Step 1: Make sure the read head is placed at the correct distance from the label. This distance is determined according to the type of read head and the size of the Job label. The distance is determined at the factory. Step 2: Place the Certified Contrast Calibration Label into the field of view as seen within the Video monitor window. Ignore the red box located within the Video monitor window. (The red box is used to set up the Job label only.) There are three sizes of bar codes printed on the calibration label. They are titled 80%, 100% and 150%. Since a Job label can be any size between .5 inches and 3 inches, the operator must use the size that comes closest to filling 80% of the field of view. Step 3: Push the Calibrate Button (4). The Screen will change to the Calibration mode. The top of the Setup box will turn yellow and say “Calibration label” . Step 4: Take the cover off of the read head to expose the video camera. With the Certified Contrast Calibration Label centered within the field of view, adjust the iris and focus on the video camera.

Calibration mode

- 25 -

Page 26

INTEGRA 9100 / 9100Q VERSION 4.28

SCREEN FUNCTIONS

Iris adjustment: The Iris on the video camera is adjusted so that the moving box within the Iris indicator (5) is centered and is green. If the Iris is not set correctly, the moving box will turn to the color of red.

5

6

Focus adjustment: Focus, located on the video camera, is adjusted so that The moving blue box within the Focus indicator (6) is “peaked” moving to the right as indicated on the Setup box. 7 Step 5: Push the “Save” button (7). The normal Setup screen will then re-appear. The system is now calibrated to ISO/IEC specifications. Replace the cover on the read head. Software now needs to learn the Job label.

Calibration Mode

Normal Setup Screen

The Setup Screen goes back to normal after Calibration This system will remember the calibration settings for all new jobs. Care should be taken to never adjust the iris (found within the read head) after the system has been calibrated. If the iris is adjusted, or the read head position is changed, the operator must re-calibrate. Calibration levels should be checked at least once a week.

- 26 -

Page 27

INTEGRA 9100 / 9100Q VERSION 4.28

2.5

SCREEN FUNCTIONS

Job Label Calibration

At the start of any old or a new Job, the operator must draw a red square around the bar code label. Allow for a maximum quiet zone on each side of the label. Pointing on the red square and dragging it across the image will re-draw the red square. When a new label is being verified or the current Job label is positioned differently, the operator must re-draw the red square. Software will not see any part of the label if positioned outside the red square. The red square is not recognized during the system Calibration process.

2.6

Label box

The Decode rate window (16) is a real time graph indicating label quality. A different color is used for each of the verification grade ranges. Next to the Decode rate window is a list of additional bar code symbol data. Label text.

The decoded alpha / numeric message.

Symbology.

What symbology is being detected.

Grade

The first box will shows the ISO/IEC grade as detected in real time. The second box will show the average ISO/IEC grade.

Blemish %

This is an indication of what percent of total bar height contains blemishes or printing errors. The first box will show the blemish percent in real time. The second box will show the average blemish percentage

Bar Growth %

Indicates Bar growth and shrinkage in percentages. The first box will show the blemish percent in real time. The second box will show the average blemish percentage. - 27 -

Page 28

INTEGRA 9100 / 9100Q VERSION 4.28

SCREEN FUNCTIONS

Labels / second Indicates how many bar code images are being analyzed per second. Xdim

This is a number that represents the microprocessor count for the smallest element found within a bar code image.

Height

Every bar code image is being measured for bar code height.

Mils

There are two boxes under this heading. The first box states the measurement of the smallest bar/space element found within the bar code image. It is stated in inches (mils). The second box will indicate the microprocessor count size for this smallest bar/space element. This is commonly called the “minimum X-dimension” for a bar code image (Xdim).

Size

There are two boxes under this heading. It is an indication (in inches) of the bar code symbols overall width and height.

2.6

ISO / IEC Parameters

The Setup screen on the INTEGRA-9100 will list 9 different parameters measured according to the ISO / IEC Bar Code Verification Standards. Each parameter will indicate a numeric number as well as a visual color change.

Color codes for ISO/IEC Grading. Reported ISO/IEC Verification parameters.

- 28 -

Page 29

INTEGRA 9100 / 9100Q VERSION 4.28

SCREEN FUNCTIONS

Alarm Function Screen

3

4

3.1 Output Matrix The Alarm Screen is used to set up specific alarm conditions. Choose the error conditions you want by checking a box listed under any of 3 outputs: LT2, LT3, LT4. These output signals are directly connected to individual relays located within the Light Tower Interface Unit. (See chapter on Light Tower Interface Unit.) Relays are used to interface with parts kickers, error markers or connected to the STOP MOTION of a press or re-winder. LT1 is generally dedicated to the green light “Good Read” indicator located on the Light Tower Interface Unit. This allows the operator to have a visual indication when software has read a bar code label correctly. Checking a box under a specific column will active the relay for the listed error conditions: Missing label, Unreadable label, Wrong message length, Mismatch, Sequence, Out of Range, Checksum, Grade error, Blemish error, Growth error, Grade warning, Blemish warning, Growth warning, and Good read. If an error condition box is not checked for any of the three outputs, then that error condition is not being checked. All error conditions used to turn “on” one of the 3 outputs are reported to the Reports screen. - 29 -

Page 30

INTEGRA 9100 / 9100Q VERSION 4.28

SCREEN FUNCTIONS

Alarm Screen

3.2

Available error conditions explained.

Missing: There are two ways to treat a “missing” bar code: ignore it or report it. If the box is checked “treat as OK” then a missing bar code will be ignored and it will not be counted in the final report. If the box is not checked, then any time a bar code is determined to be “missing” software will report it as an error condition.

Unreadable: An unreadable bar code means software has determined there is substantial evidence that a bar code is actually present (in contrast to missing) but was totally unreadable. To detect the difference between “missing” and “unreadable” bar code is designed to help the operator ignore printing conditions (especially at the beginning of a job) where a missing label is normal and should not be reported as an error.

Wrong length:

- 30 -