The text of a manual · part 2 of 7
INTEGRA 9100 Operator's Manual, pages 11 to 20
Pages 11 to 20 of 70
The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Label Vision LNT-92A
Page 11
INTEGRA 9100 / 9100Q VERSION 4.28
INSTALLATION
Read Head Placement continued
SINGLE -LANE READ HEAD. LNT-92A SERIES
The Single Lane Read Head uses a swivel pole joint which can be locked down at a specific angle and object distance. The object distance refers to the distance between the bottom of the read head bezel and the surface of the label. This distance will vary from job to job depending on the width of the bar code label. The read head should be mounted away from any solenoids, motors, relays, or AC lines. Also, it should be mounted away from overhead fluorescent lights. LNT-92A Single Lane Read Head
WARNING: An overhead fluorescent light source, if allowed to illuminate any part of the label surface, will induce a 60 hertz error signal into the INTEGRA system. This may cause errors in ISO/IEC grading.
READ HEAD
OBJECT DISTANCE (FACTORY SPECIFIC)
SURFACE OF LABEL
Object distance using the LNT-92A read head - 11 -
Page 12
INTEGRA 9100 / 9100Q VERSION 4.28
INSTALLATION
PHOTO-EYE LOCATION and TYPE The photo-eye is sent already connected to a bracket which can be mounted anywhere that allows the operator the ability to adjust its position easily. The operator may need to adjust the photo-eye position many times during a day. There are two types of Photo-eyes used with this system: Through the Web and Reflective. Through the Web type detects the gap between labels. The Reflective type requires the photo-eye to detect a printed registration mark. See pictures below.
1. This is a picture of a Throughthe- web Photo-eye mounted on its bracket.
2. This is a picture of a Reflective Photo-eye mounted on its bracket.
1. Through the Web Many printers die cut the labels and then removes the unwanted portion of the matrix created by the die cut. This creates a separation of the labels, which can be seen by a “through the web” photo eye. Thus, the photo eye at the start of every label generates a registration signal. 2. Reflective A reflective photo eye is designed to see contrast changes on the web surface. A registration mark can be printed on the edge of the web. When the photo eye sees the registration mark, a registration signal is generated in conjunction with the presence of a bar code symbol.
- 12 -
Page 13
INTEGRA 9100 / 9100Q VERSION 4.28
INSTALLATION
ENCODER LOCATION (ENCODER IS OPTIONAL) An encoder is an option that can be used in place of a photo-eye. The encoder will automatically generate a Registration trigger for each label. The advantage of using an encoder instead of a photo-eye is that a photo-eye needs to be adjusted for every JOB. With a photo-eye, it may also be necessary to change from a “Through the Web” type to a “Reflective” type. The encoder comes with a mounting kit. See below picture. It needs to be mounted on any “gear driven” idler found along the path of the label stock. All necessary mounting brackets are supplied.
Encoder with Mounting Hardware
- 13 -
Page 14
INTEGRA 9100 / 9100Q VERSION 4.28
INSTALLATION
Software Rebuilds and Upgrades The system is delivered with software fully installed. In the event a major software failure occurs, call the LVS factory at 1-800-432-9430. If recommended, a Software Rebuild may be necessary to solve the problem. The Software Rebuild CD contains all programs and all drivers necessary to return the INTEGRA-9100 back to factory specifications. Also, throughout the coarse of time, various Software Upgrades may be supplied. Upgrades are used to enhance the system or perhaps to solve software glitches.
SOFTWARE UPGRADES Software Upgrades are supplied to you on a CD. To upgrade a system the following steps are taken: 1. Insert the Upgrade CD into the DVD driver. It will automatically load. 2. A pop-up window will prompt you to upgrade the existing software. Choose yes. 3. Remove the CD and restart your computer.
SOFTWARE REBUILD Each system has a CD, which contains the entire build program. To rebuild systems software the following steps are taken: 1. Insert the Rebuild CD into the DVD drive. Press [Ctrl] + [Alt] + [Del] to restart the system. 2. The automatic restore program will ask, “Will you use the changer drive? [Y / N]. Type N. 3. Input the number corresponding to where the backed up data is to be restored in [SELECT NO.1], then press ENTER. 4. The following message appears when restoration is complete: Restore complete, press any key. 5. Press Enter key to return to MS-DOS. 6. Eject the CD backup disk, and then restart the system. WARNING: WHEN IT IS NECESSARY TO REBUILD THE SOFTWARE, ALL EXISTING JOB REPORTS AND RUN REPORTS WILL BE LOST. IT MAY BE NECESSARY TO ARCHIVE THESE FILES TO ANOTHER CD PRIOR TO THE REBUILD COMMAND. - 14 -
Page 15
INTEGRA 9100 / 9100Q VERSION 4.28
INSTALLATION
PREVENTIVE MAINTENANCE Maintenance will consist of monthly and annual duties. Since there are no moving parts within this system, there are no parts that wear out. MONTHLY Preventive Maintenance schedule: 1. Remove the read head cover. Using an air hose (50 to 80 psi), blow out the inside of the read head. This should remove any paper dust that might have settled on the lens, glass window, or fluorescent lights. WARNING: NEVER REMOVE THE LENS FROM THE VIDEO CAMERA. 2. Clean the outside of the glass window with a glass cleaner and a soft paper towel. 3. Clean the 8 fluorescent lights, located on the read head bezel, with a cotton swab and window cleaner. 4. There are two optical windows on the photo-eye. Clean them with a cotton swab and window cleaner.
ANNUAL Preventive Maintenance schedule: 1. Clean or replace the filters on the computer. Follow manufacturer guidelines. 2. Remove the read head cover. Clean the outside lens of the video camera. WARNING: NEVER REMOVE THE LENS FROM THE VIDEO CAMERA. There is nothing to clean inside. 3. Replace the Contrast Calibration Label. 4. Clean the inside and outside of the read head glass window with window cleaner and a soft paper towel.
BI-ANNUAL Preventive Maintenance schedule: 1. Replace the light bezel on the read head.
- 15 -
Page 16
INTEGRA 9100 / 9100Q VERSION 4.28
INSTALLATION
SPARE PARTS LIST PART NUMBER
PART DESCRIPTION
AVERAGE LIFE
LIG0030 LIG0006 LIG0031 VID0030 VID0031 VID0032 VID0033 LAB0008 LIG1025 LIG1026
LOL-10.0 strobe lamp LOL-2.5 strobe lamp LOL-5.0 strobe lamp 12“ DC Fluorescent assembly 16“ DC Fluorescent assembly 18“ DC Fluorescent assemb ly 20“ DC Fluorescent assembly Contrast Calibration Label LNT-92A Light bezel LNT-93A Light bezel
2 years 2 years 2 years 30000 hours 30000 hours 30000 hours 25000 hours 1 year 2 years 2 years
- 16 -
Page 17
INTEGRA 9100 / 9100Q VERSION 4.28
INSTALLATION
DESCRIPTION OF OPERATIONS The video signa l from the read head is sent to firmware and software located inside the computer. The Windows based software program processes the many functions necessary to track the trends of print quality for the bar code image. A matrix of error detections are ava ilable to shut down the machine or simply sound an alarm. If an error is detected, the operator can program the INTEGRA 9100 / 9100Q to shut down the press or rewinder. A final report is generated which contains the ISO/IEC overall grade point average for each label. The OPERATE Screen has a real-time graph for ISO/IEC overall label grade as well as individual ISO/IEC grades for Decodability, Modulation, and Contrast. There is also a real time graph for bar growth and blemishes. This will help the operator to monitor specific changes in bar code quality before they become a problem. All levels of quality can be preset by the operator to sound an alarm if preset conditions are exceeded. The special blemish detector is used to detect ink spots or voids. It can be set to sound an alarm on blemishes as small as 5% of the total bar height. A real time graph for blemish detection is displayed on the Operate Screen. The INTEGRA 9100 / 9100Q uses a Windows based software operating system. All functions are divided into 6 screens: 1. Welcome Screen- This screen displays the operating systems serial number and run number. 2. Job Screen- This screen is used to create files to store important information concerning previous jobs. It can update the operator as to what kind of label they use, the last job summary, sequence information and video setup from the last job. 3. Setup Screen- All automatic controls necessary to align the bar code symbol to the INTEGRA 9100 / 9100Q are on this screen. This is where all calibration functions occur. 4. Alarm Screen- This screen enables the user to define what error conditions will activate the relay contacts out and/ or activate one of three warning light outputs. 5. Operate Screen- This screen displays a graph for various conditions necessary to track trends in print quality. Bar growth, bar shrinkage, blemish detection, label grade, web speed, decoded data and more. This screen is generally what the operator would monitor during a job of label inspection. 6. Reports Screen- This screen gives a summary or log of all labels read during a RUN or during a JOB. These reports can be outputted to a printer. - 17 -
Page 18
INTEGRA 9100 / 9100Q VERSION 4.28
SCREEN FUNCTIONS
WELCOME SCREEN
The Welcome Screen is important when problems occur and you need technical support. The technician will need to know what run and what serial number is being used. It is found on this screen.
18
Page 19
INTEGRA 9100 / 9100Q VERSION 4.28
SCREEN FUNCTIONS
JOB FUNCTION SCREEN
2 4
3
1.0
JOB SCREEN
The Job Screen has many functions. The main functions are: choosing a job, password protection, choosing a Check digit routine, and Range checking. The operator can choose an existing job or start a new one. To start a new job, push the Create new job button. The operator proceeds by typing in a new job name. Software will then ask the operator to choose between the default settings or the previous job settings. Most operators will choose the default settings providing the default parameters were set up correctly.
1.1 Setting Default parameters There is a file listed on the Job screen called “default.job”. This file is what the operator uses to set up all variable parameters located within the INTEGRA 9100 / 9100Q software. The operator should take the time to choose the “default.job”. (2) Then, review all screens. The values you choose while in the “default.job” file will become the Default parameters for all new jobs. Pay particular attention to the alarm screen.
- 19 -
Page 20
INTEGRA 9100 / 9100Q VERSION 4.28
1.2
SCREEN FUNCTIONS
Password protection
There is a box titled “Allow changes” under the Job options section. Removing the check mark will cause the current job to be password protected.
1.3
Live output
Within the “Job options” box there is as box titled “Live output”. This feature allows the operator to send all reported bar code verification information directly to a printer or any other RS-232 product via the serial port. This would occur during the “Operate mode” only. Serial port communications are set up by changing the parameters listed in the “Serial port” box. 6
5 9 8
Job screen
1.4
Check digit (9)
This system always performs the MOD 103 check digit algorithm on code 128. If the hidden check character is wrong, the label won’t be read at all. There are many special check digit routines. Currently, this system supports 3131 weighting algorithm providing the symbol starts at the most significant digit and Mod 11.
1.5
The Description box
The description box can contain a short or long message. (5) Place the cursor inside the box and enter. The operator can type any length of message. Remember that the first
- 20 -