Page 51

INTEGRA 9100 / 9100Q VERSION 4.28

MINIMUM REFLECTANCE

The ISO/ANSI formula for Minimum Reflectance is based on the DC amplitude difference between the greatest value of reflectance (spaces) and the smallest value of reflectance (bars) as observed in a SRP. It passes if the smallest value of reflectance is less than or equal to 50% of the greatest value. LVS software uses a MANAGED GLOBAL THRESHOLD (MGT) as established during SETUP. Any reflectance value deviation from “normal” will be detected and, consequently, will vary the Symbol Grade Score. “Normal” is defined as the level of reflectance obtained from the ISO/ANSI verified TARGET LABEL during SETUP. The INTEGRA-9000 does not grade Minimum Reflectance as a PASS or FAIL, it is reported as a defect when software compares it to what is “normal”. This is a Y-axis measurement. But, if a label degraded to where the minimum reflectance is greater than half of maximum reflectance, then the VSP could never duplicate what was measured during SETUP, and therefore report an “F” GRADE. Software checks for minimum reflectance every .006 inch of bar height.

MANAGED GLOBAL THRESHOLD (MGT) The Managed Global Threshold is the key to the INTEGRA-9100 process of verification. This method allows software to monitor the Y-axis positive and negative peaks of the VSP and reports any changes form what was determined as “normal” during SETUP. Another name for MGT is SWEEP. When a bar code symbol begins to have problems (Y-axis problems), it is first to show at the extreme peaks, both positive and negative, of the VSP. Software spends most of its time monitoring these peaks.

MINIMUM EDGE CONTRAST The ISO/ANSI formula for Minimum Edge Contrast is based on the smallest DC amplitude of a bar/space Transition as observed in a SRP/VSP. It is a Y-axis measurement. If the deviation is greater than 15% it is considered a PASS. Our system will report an “F” grade for any edge contrast level less than 15%. The “Managed Global Threshold” (MGT) method of measurement is used to establish edge contrast deviation percentages. Software checks for Minimum Edge Contrast every .006 inch of bar height.

- 51 -

Page 52

INTEGRA 9100 / 9100Q VERSION 4.28

SYMBOL CONTRAST Symbol contrast is measured the same way Minimum Edge Contrast was measured. It is a Y-axis measurement and is based on the absolute measurement established during SETUP. The amount of sweep measured on the “target label” is how symbol contrast is defined. Any minute change in symbol contrast will be detected at the positive and negative peaks of the SRP then deducted from the symbol grade score. The percentage of undecodable lines caused by the reduced amplitude of the SRP will follow ISO/ANSI’s contrast grade percentages very closely. Software checks for deviations in Symbol Contrast every .006 inch of bar height.

MODULATION Modulation is ratio of the minimum edge contrast to Symbol contrast inside an SRP. The grade scale for modulation was established during SETUP. It is a Y-axis measurement. Modulations changes are first noticed at the positive and negative peaks of the SRP. This is very similar to Symbol Contrast. Symbol contrast errors will change a multitude of peak amplitudes, where as when Modulation errors occur, only one or two peaks are effected. Software is trained to monitor both types of errors. These changes in modulation affect the overall percentages very close to the ISO modulation percentages. Due to the differences in scales used to determine the ISO/ANSI grades, Modulation errors will be reported slightly higher than actuality. Software checks for deviations in Modulation every .006 inch of bar height. It will grade according to specifications about 10% harder than recommended. This condition is created because software is trying to follow Symbol contrast, Decodability, and Modulation at the same time.

DECODE Decode is a Pass / Fail measurement. This rule applies to not only making sure that a bar code symbol can be decoded but also whether the check digit routine is consistent with the rules set up for standard check digits or specially developed check digit routines. Software checks for Decode every .006 inch of bar height. DEFECTS Another unique quality for the INTEGRA-9100 is in its ability to detect all types of blemishes large or small that affect the decode rate of a given label. It is a Y-axis measurement. If the TARGET label used during setup of the INTEGRA-9100 software indicates that there should be 200 decodes per label, then any blemish defect larger than .006 inch would decrease the decode rate by a percentage equal to the height of the defect. - 52 -

Page 53

INTEGRA 9100 / 9100Q VERSION 4.28

The ISO/ANSI GRADE labels made by Applied Images contain calibrated labels that help define what is an acceptable “spot” or “void” defect size. The INTEGRA-9100 does not use this scale of measurement and will not grade the Primary Calibration Standards according to a sliding scale from A (4.0) to F (.5). Instead, software is trained to sound an alarm on “any” defect level detected that is greater than 5% of the bar height. The actual level is set up by the operator during the SETUP process. The Primary Calibration labels made by Applied Image for “spots” and “voids” were made by creating a “spot” or “void” as a line along the entire bar height of the symbol. In this way, no matter where the operator would scan across the calibration label, a “spot” or “void” error would be found. Due to this one-dimensional approach to ISO/ANSI verification that wands inherently have, it is easy to see why the “spot” and “void” calibration standards were made in this manner. But, a traditional wand or laser based verifier cannot detect a “real” spot or void. A “real” spot or void would cause that line of bar code data to be undecodable. A standard verifier will not report whether the scanned line was good or bad. It doesn’t even know it exists. Vision based verification is a twodimensional process. In the two-dimensional world of vision, “real” spots or voids are called “blemishes”. Vision systems look at bar code data contiguously and will know when a line of bar code data is “not” decodable. The INTEGRA-9100 system checks every .006 inch of bar height for blemishes. The acceptable size for a blemish error is defined during SETUP.

This is an A GRADE label according to verification standards. The INTEGRA9000 will see this type of error as a Blemish.

- 53 -

Page 54

INTEGRA 9100 / 9100Q VERSION 4.28

DECODABILITY Decodability is a measure of how close the bar and space widths match ideal values and is an X-axis measurement. ISO/ANSI specifies a different algorithm for each symbology. The INTEGRA 9100 measures the decodability from the sums of adjacent bars and spaces, and implement special algorithms for UPC digits 1,2,7, and 8. The lookup table used to convert a microprocessor count to an element width will also includes 5 bits (32 possible values) for decodability. The INTEGRA 9100 remembers the worst decodability seen for the entire scan line. Code 39 and CodaBar have a space called the inter-character gap. The ISO/ANSI specification for decodability does not look at the gap, but the INTEGRA 9100 does. If the gap is more than 1X, then the system will give the symbol a lower grade. The measurement of Decodability is checked every .006 inch of bar height.

QUIET ZONES Quiet Zones are a measurement of uniform light contrast, adjacent to the outer edges of the left and right guard bars. This is a Pass / Fail measurement and is an intricate part of what software needs to see in order to decode a particular symbology. Software checks for presence of a Quiet Zone every .006 inch of bar height.

OVERALL SYMBOL GRADE The INTEGRA 9100 system cannot define individual problems associated with the SRP/VSP for a given label. It can only determine that its overall Symbol Grade is not how the “target symbol” measured. A line score is determined for each scan line. The line score is a number between 0 and 32. Undecoded scan lines get a line score of 0. Decoded scan lines get a score between 1 (worst) and 32 (best). This is a linear scale and correlates to the ISO/ANSI standards. - 54 -

Page 55

INTEGRA 9100 / 9100Q VERSION 4.28

The sum of all line scores is called the “symbol score”. If a symbol was perfect, it would be equal to 32 times the height of the symbol. Typically, the number is somewhere between 15 and 20 times the height of the symbol. The INTEGRA-9100 software will see a 100% U.P.C. bar code symbol about 150 times. Since software checks for bar code quality every .006 inch of bar height, we can multiply 150 times .006 inch. This equals to .9 inch which is what a 100% U.P.C. label should measure. This means that software will see this label 150 times at 10 feet per minute or at 1000 feet per minute. It will see the label this many times whether it is in a “ladder” or “picket fence” orientation. According to ISO specifications a verifier needs to scan a bar code symbol 10 times in order to get an accurate picture of bar code quality. The INTEGRA-9100 goes well beyond ISO requirements. Even a truncated UPC label measuring .25 inches would be scanned over 40 times, at any press speed, and in any orientation.

TRUNCATION / BAR HEIGHT

The INTEGRA-9100 measures and checks for the presence of a bar code symbol every .006 inch of bar height. During SETUP, software determines the height of a bar code label by counting how many lines were decoded. A truncated problem will show up as a “blemish”. Software can be set to sound an alarm when a bar code label becomes truncated by more than 5%.

OPACITY For the printing industry OPACITY is defined as the property of a material which allows you to see through a printed label substrate. The INTEGRA 9100 can be used to check for OPACTIY by placing a half black and half white background behind the “job label”. Any changes in OPACITY would then be detected as a change in contrast. A background plate could also be made to appear like the product the label is being used on. SETUP would see the different looking background due to OPACITY and the operator would determine what level of decode rate would be acceptable. Any deviation from “normal” due to OPACITY issues would be tracked. - 55 -

Page 56

INTEGRA 9100 / 9100Q VERSION 4.28

This type of check cannot be done with wand or laser based verifiers at press speeds. It is an area of neglect that deserves some mention. Opacity is one of the most common reasons for a bar code label to not be read at the retail store. This is due to printers checking for bar code quality without placing it onto the final product. The INTEGRA-9100 verifies problems with Opacity every .006 inch of bar height. The INTEGRA-9100 “Operations Screen” will show the Label Text and trend analysis for ISO/ANSI Grade, Blemish Percent, and Bar Growth / Shrinkage Percent for up to 8 different bar code symbols on one computer screen. Software is set to handle up to 60 different bar code symbols per second, per lane. Alarms can be set for the following: No dup licates Mismatch errors Checksum errors Sequence errors ISO/ANSI grade errors Blemish errors Bar shrinkage errors Bar growth errors Missing label errors Good read indicator

Software maintains a REPORTS LOG for all symbols read. It will list the Job numb er, Job start / stop time, what the ISO/ANSI grade was for every label and what kind of error was detected, and each line of data is date and time stamped.

- 56 -

Page 57

INTEGRA 9100 / 9100Q VERSION 4.28

3 LANE AND 8 LANE SYSTEM BOARD INPUT / OUTPUT PINS Pin 1 GND Pin 2 CAMERA A SHIELD Pin 3 GND Pin 4 CAMERA C SHIELD Pin 5 GND Pin 6 PXC SHIELD – BNC Pin 7 GND Pin 8 MUX 1 IN Pin 9 GND Pin 10 STROBE TRIGGER Pin 11 Pin 12 ACK RESET IN Pin 13 XTRA OUT 1 Pin 14 SPARE OUT 2 Pin 15 GND Pin 16 GND Pin 17 CAMERA A VIDEO Pin 18 CAMERA B VIDEO Pin 19 CAMERA C VIDEO Pin 20 CAMERA D VIDEO Pin 21 PCX VIDEO Pin 22 MONITOR A VIDEO Pin 23 GND Pin 24 XTRA IN 1 Pin 25 SPARE IN 2 Pin 26 PHOTO-EYE IN Pin 27 FRAME SYNC Pin 28 GND Pin 29 LIGHT TOWER 1 OUT Pin 30 LIGHT TOWER OUT 2 Pin 31 GND Pin 32 CAMERA B SHIELD Pin 33 GND

4 AND 8 INTEGRA 9000 COMPUTER BOARD

PIN 1

44 Pin

PIN 44

Pin 36 MONITOR A SHIELD Pin 37 GND Pin 38 LIGHT TOWER OUT 3 Pin 39 ACTIVE OUT Pin 40 GND Pin 41 RELAY COIL Pin 42 GND - 57 -

Page 58

INTEGRA 9100 / 9100Q VERSION 4.28

Pin 34 CAMERA D SHIELD Pin 35 GND

Pin 43 GND Pin 44

Cable Assembly CAB0120 (10 feet). Cable Assembly CAB0116 (30 feet). From the Read Head to the Computer with 1 to 4 lane system.

- 58 -

Page 59

INTEGRA 9100 / 9100Q VERSION 4.28

Cable Assembly CAB0157 (10 feet). From the Light Tower to the Read Head.

- 59 -

Page 60

INTEGRA 9100 / 9100Q VERSION 4.28

Cable Assembly CAB0159 (18 inches). From the Camera to the Camera Interface Board.