Page 81
Servicing the Timeclock
5. Disconnect the transformer cable from the timeclock’s main board.
Number
Description
1
Transformer cable
2
Hooks for routing the cable
3
Transformer connection to the main board (DC power)
6. Trace the wire back to the transformer, freeing it from the hooks molded into the base of the timeclock.
Series 4000 Badge Timeclock User’s Guide
4-33
Page 82
Chapter 4
Maintaining the Timeclock
7. Lift the transformer from behind the wire clip and out of the timeclock.
8. Unplug the AC power cord from the top of the transformer and lay the transformer in a safe place.
4-34
ADP, Inc.
Page 83
Servicing the Timeclock
9. Use a utility knife to remove the two round spacers from the back of the timeclock where the transformer had been positioned.
Number
Description
1
Badge reader spacers molded into the base.
10. Install the transformer back in the timeclock as follows: a. Position the transformer behind the wire clip in the timeclock. b. Route the transformer cable to its connection point on the main board and plug the connector in. c. Plug the transformer back into the AC outlet. If you are plugging the timeclock into an external AC outlet, route the power cord out of the timeclock and re-assemble the strain relief clip to secure the cord. 11. Close and lock the timeclock cover using the security wrench.
Series 4000 Badge Timeclock User’s Guide
4-35
Page 84
Chapter 4
Maintaining the Timeclock
Installing the Reader Spacers You need to widen the badge reader slot if the badges your employees use are more than .125 in (3.175 mm) thick. To widen the slot, you install two reader spacers that come molded into the base of the timeclock.
Note If you did not remove the spacers before you installed the Series 4000 timeclock, you will need to remove them as explained in “Removing the Reader Spacers” on page 4-32. 1. Open the timeclock’s cover by using the security wrench to loosen the security screw on the right side of the timeclock. 2. Use a Phillips screwdriver to loosen the two captive screws inside the timeclock cover that hold the badge reader cover in place.
4-36
Number
Description
1
Screws that hold the badge reader cover in place
ADP, Inc.
Page 85
Servicing the Timeclock
3. On the outside of the timeclock cover, press the two spacers onto the tops of the channels that hold the screws for the reader cover. 4. Position the reader cover back into place and tighten the two screws.
Number
Description
1
Badge reader spacers
2
Badge reader cover
Series 4000 Badge Timeclock User’s Guide
4-37
Page 86
Chapter 4
Maintaining the Timeclock
Replacing the Badge Reader Cover 1. Open the timeclock’s cover by using the security wrench to loosen the security screw on the right side of the timeclock. 2. Use a Phillips screwdriver to loosen the two captive screws inside the timeclock cover, that hold the badge reader cover in place.
4-38
Number
Description
1
Screws that hold the badge reader cover in place
ADP, Inc.
Page 87
Servicing the Timeclock
3. Position the new reader cover into place and tighten the two screws.
Series 4000 Badge Timeclock User’s Guide
4-39
Page 88
Chapter 4
Maintaining the Timeclock
Replacing the AC Power Supply (transformer) 1. Before you begin, collect data from the timeclock using your host application software. For more information, see the “Using the Host Application Software to Collect Data” section in this chapter. 2. Open the timeclock’s cover by using the security wrench to loosen the security screw on the right side of the timeclock. 3. Unplug the transformer from the AC power source. If you plugged the timeclock into an external outlet, disassemble the strain relief clip at the power cord’s point of entry into the timeclock.
4. Unplug the power cord from the transformer.
4-40
ADP, Inc.
Page 89
Servicing the Timeclock
5. Disconnect the transformer cable from the timeclock’s main board.
Number
Description
1
Transformer cable
2
Hooks for routing the cable
3
Transformer connection to the main board (DC power)
6. Trace the wire back to the transformer, freeing it from the hooks molded into the base of the timeclock.
Series 4000 Badge Timeclock User’s Guide
4-41
Page 90
Chapter 4
Maintaining the Timeclock
7. Lift the transformer from behind the wire clip and out of the timeclock.
8. Unplug the AC power cable from the top of the transformer. 9. Install the new transformer as follows: a. Plug the AC power cord into the top of the transformer. b. Position the transformer behind the wire clip in the timeclock. c. Route the transformer cable to its connection point on the main board and plug in the connector. d. Plug the transformer back into the AC outlet. If you are plugging the timeclock into an external AC outlet, route the power cord out of the timeclock and re-assemble the strain relief clip to secure the cord. 10. Close and lock the timeclock cover using the security wrench.
4-42
ADP, Inc.