Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 10 of 15

User's Guide: Series 4000 Badge Timeclock, pages 91 to 100

Pages 91 to 100 of 146

The original document is the PDF (1.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Kronos System 4500

Page 91

What Are the Maintenance Functions?

What Are the Maintenance Functions? Maintenance Mode allows you to display technical information about the timeclock, perform configuration functions, and execute the diagnostic tests. The diagnostic tests are extremely useful when troubleshooting hardware malfunctions. The following figure is a sample of Maintenance Mode:

2:03

PM

Fri Aug - 24 - 2001 Maintenance Mode

Comm Setting

Symbology Setting

Display Setting

Restart

Audio Setting

FACTORY DEFAULT

Date/Time Setting

More...

Note You can access Maintenance Mode only if you are authorized to use a Maintenance badge at the Series 4000 timeclock.

Series 4000 Badge Timeclock User’s Guide

4-43

Page 92

Chapter 4

Maintaining the Timeclock

The following list shows the Maintenance functions that you can perform using the Series 4000 timeclock. The remainder of this chapter contains more information about each of these functions. Settings !

Audio Setting (basic configuration)

!

Communication Setting (basic configuration)

!

Date/Time Setting (basic configuration)

!

Display Setting (basic configuration)

!

Symbology Setting (basic configuration)

Reports !

Database Report

!

Device Status Report

!

Ethernet Report

!

File System Report

!

Memory Report

!

Readers Report

Diagnostic Tests !

Badge Test

!

Beeper Test

!

Display Test

!

Keypad Test

!

LED Test

!

Sequential Tests

Miscellaneous

4-44

!

Change Password

!

FACTORY DEFAULT

!

Delete All Punches

!

Restart

ADP, Inc.

Page 93

What Are the Maintenance Functions?

To perform Maintenance functions, you must first access Maintenance Mode. Then, you can select the desired Maintenance command.

Note The first time that you power up the Series 4000 timeclock, the Communication Settings screen will appear. For more information about what to enter in communication settings, see the “Communication Setting (basic configuration),” section in this chapter. To access Maintenance Mode: Step

Display

Action

1

Idle screen

Swipe the Maintenance badge from top to bottom.

2

Maintenance Login

Type the password (up to 6 digits), and press ENTER. If you enter the wrong password, an error message appears. Press CLR to clear the screen, then type the password again.

3

Maintenance Mode idle screen

Press the desired Maintenance Command soft key.

To exit from Maintenance Mode, press ESC.

Note If the timeclock is idle for 45 seconds without any input from the keypad, it automatically exits Maintenance Mode and returns to Employee Mode.

Series 4000 Badge Timeclock User’s Guide

4-45

Page 94

Chapter 4

Maintaining the Timeclock

Performing Maintenance Functions This section presents brief descriptions of Maintenance functions, and instructions about how to perform them.

Audio Setting (basic configuration) Use Audio Setting to adjust the volume of the beeper and to enable or disable the keys click when pressed. The beeper volume is saved when you exit the Beeper Volume field. The Beeper Volume soft key is used to test the volume.

Note These settings are part of the basic configuration of the timeclock. You must complete these settings when you power up the timeclock for the first time and if you replace the cover assembly.

4-46

Step

Display

Action

1

Maintenance Mode idle display

Press the Audio Setting soft key.

2

Beeper Volume (1-14)

Press the (+) and (-) soft keys to adjust the volume, then press ENTER.

3

Key Click

Press the (Off) and (On) soft keys to enable or disable the key click, then press ENTER.

ADP, Inc.

Page 95

Performing Maintenance Functions

Communication Setting (basic configuration) Use Communication Setting to establish communications with the host application. This screen will appear if any information is missing from the text boxes when the Series 4000 timeclock is powered on. The following settings are in Communication Setting: !

Device ID - A six-digit ID number that identifies the timeclock. The host application uses this number to identify the timeclock.

!

IP Address - The IP address, including the periods, assigned to the timeclock by your system administrator.

!

Gateway - The IP address, including the periods, of the default device that forwards data to the host application. This field holds up to 15 digits.

!

Subnet Mask - A number that identifies a subnetwork so that an IP address can be found on a local area network (LAN). This field holds up to 15 digits.

Note These settings are part of the basic configuration of the timeclock. You must complete these settings when you power up the timeclock for the first time and if you replace the cover assembly. You need to enter the periods as you type the settings in Communication Setting. When you complete the screen, the timeclock reboots so that the settings can take effect. Step

Display

Action

1

Maintenance Mode idle display

Press the Communication Setting soft key.

2

Device ID

Type the Device ID setting and press ENTER.

3

IP Address

Type the IP Address setting and press ENTER.

4

Gateway

Type the Gateway setting and press ENTER.

5

Subnet Mask

Type the Subnet Mask setting and press ENTER.

Series 4000 Badge Timeclock User’s Guide

4-47

Page 96

Chapter 4

Maintaining the Timeclock

Date/Time Setting (basic configuration) Use Date/Time Setting to set the date and time on the timeclock display. Note that you must enter the time in 24-hour format.

Note These settings are part of the basic configuration of the timeclock. You must complete these settings when you power up the timeclock for the first time and if you replace the cover assembly.

Step

Display

Action

1

Maintenance Mode idle display

Press the Date/Time Setting soft key.

2

Date (mm/dd/yyyy)

Do one of the following: ! !

3

Time (24-hour)

Do one of the following: ! !

4-48

Press ENTER to accept the default date. Type the date using mm/dd/yyyy format, and press ENTER. Press ENTER to accept the default time. Type the time using hh:mm format, and press ENTER.

ADP, Inc.

Page 97

Performing Maintenance Functions

Display Setting (basic configuration) Use Display Setting to set the contrast and brightness of the display screen. The screen shows the effect after you have completed the transaction.

Note These settings are part of the basic configuration of the timeclock. You must complete these settings when you power up the timeclock for the first time and if you replace the cover assembly.

Step

Display

Action

1

Maintenance Mode idle display

Press the Display Setting soft key.

2

Contrast (16-22)

Press the (+) and (-) soft keys to adjust the contrast of the display, then press ENTER.

3

Brightness (4-16)

Press the (+) and (-) soft keys to adjust the brightness of the display, then press ENTER.

Series 4000 Badge Timeclock User’s Guide

4-49

Page 98

Chapter 4

Maintaining the Timeclock

Symbology Setting (basic configuration) Use Symbology Setting to indicate the type of bar code used on your employees’ badges, so that the timeclock can read the badges properly.

Caution If you shut the Interleaved 12-of-5 setting off, you will not be able to read a maintenance badge, preventing you from accessing Maintenance Mode.

Note These settings are part of the basic configuration of the timeclock. You must complete these settings when you power up the timeclock for the first time and if you replace the cover assembly.

Step

Display

Action

1

Maintenance Mode idle display

Press the Symbology Setting soft key.

2

Code 3-of-9

For each of the symbology settings, do one of the following:

12-of-5 UPC-A UPC-E

! !

Press ENTER to accept the default setting. Press the toggle soft keys to select OFF or ON and press ENTER.

Code 128 EAN-8

Note

EAN-13

Press ENTER on the last field to complete the transaction.

Codabar

4-50

ADP, Inc.

Page 99

Performing Maintenance Functions

Database Report Use Database Report to display information about the database. Step

Display

Action

1

Maintenance Mode idle display

Press the More... soft key twice.

2

Maintenance Mode display

Press the Database Report soft key.

Device Status Report Use Device Status Report to display information about the timeclock such as: !

Application version

!

Boot version

!

Comm version

!

OS version

Step

Display

Action

1

Maintenance Mode idle display

Press the More... soft key twice.

2

Maintenance Mode display

Press the Device Status Report soft key.

Series 4000 Badge Timeclock User’s Guide

4-51

Page 100

Chapter 4

Maintaining the Timeclock

Ethernet Report Use Ethernet Report to display the following information about the Ethernet connection to the timeclock: !

Speed

!

Receive error count

!

False carrier count

!

Remote Faults

Step

Display

Action

1

Maintenance Mode idle display

Press the More... soft key twice.

2

Maintenance Mode display

Press the Ethernet Report soft key.

File System Report Use File System Report to display the amount of space available in the timeclock.

4-52

Step

Display

Action

1

Maintenance Mode idle display

Press the More... soft key twice.

2

Maintenance Mode display

Press the File System Report soft key.

ADP, Inc.