Page 101

Performing Maintenance Functions

Memory Report Use Memory Report to display the RAM size in the timeclock and the amount of available RAM. Step

Display

Action

1

Maintenance Mode idle display

Press the More... soft key twice.

2

Maintenance Mode display

Press the Memory Report soft key.

Readers Report Use Readers Report to display information about the bar code reader: Step

Display

Action

1

Maintenance Mode idle display

Press the More... soft key twice.

2

Maintenance Mode display

Press the Readers Report soft key.

Series 4000 Badge Timeclock User’s Guide

4-53

Page 102

Chapter 4

Maintaining the Timeclock

Badge Test Use Badge Test to check a badge or the badge reader. (The Badge test is not part of the “Sequential Tests” function on page 4-56.) Step

Display

Action

1

Maintenance Mode idle display

Press the More... soft key.

2

Maintenance Mode display

Press the Badge Test soft key.

3

Symboloy

Swipe a badge.

Badge Data

Beeper Test Use Beeper Test to check the Beeper. The beeper will beep twice at two different pitches during this test. (The Beeper test is part of the “Sequential Tests” function on page 4-56.) Step

Display

Action

1

Maintenance Mode idle display

Press the More... soft key.

2

Maintenance Mode display

Press the Beeper Test soft key.

3

Start Test?

Do one of the following: ! !

4-54

Press ENTER to accept the default answer. Press the toggle soft keys to select YES or NO, and press ENTER.

ADP, Inc.

Page 103

Performing Maintenance Functions

Display Test Use Display Test to check the timeclock display. The timeclock lights up the four quadrants of the display in a pattern during this test. (The Display test is part of the “Sequential Tests” function on page 4-56.) Step

Display

Action

1

Maintenance Mode idle display

Press the More... soft key.

2

Maintenance Mode display

Press the Display Test soft key.

3

Start Test?

Do one of the following: ! !

Press ENTER to accept the default answer. Press the toggle soft keys to select YES or NO, and press ENTER.

Keypad Test Use Keypad Test to check the keypad. (The Keypad test is not part of the “Sequential Tests” function on page 4-56.) Step

Display

Action

1

Maintenance Mode idle display

Press the More... soft key.

2

Maintenance Mode display

Press the Keypad Test soft key.

3

Key

Type various keys on the keypad, then press ESC to exit the Test Mode.

Series 4000 Badge Timeclock User’s Guide

4-55

Page 104

Chapter 4

Maintaining the Timeclock

LED Test Use LED Test to check the timeclock’s LEDs. During the test, the three LEDs in the top right corner of the timeclock flash in sequence twice. (The LED test is also part of the “Sequential Tests” function.) Then, the bottom LED remains lit to indicate that the timeclock is receiving power. Step

Display

Action

1

Maintenance Mode idle display

Press the More... soft key.

2

Maintenance Mode display

Press the LED Test soft key.

3

Start Test?

Do one of the following: ! !

Press ENTER to accept the default answer. Press the toggle soft keys to select YES or NO, and press ENTER.

Sequential Tests Use Sequential Test to run through the Display, LED, and Beeper diagnostic tests. The test is finished after sounding two pitches for the Beeper test.

Note You can run each test included in this Sequential Tests function individually, using each test’s own maintenance function.

4-56

Step

Display

Action

1

Maintenance Mode idle display

Press the More... soft key.

2

Maintenance Mode display

Press the Sequential Tests soft key.

ADP, Inc.

Page 105

Performing Maintenance Functions

Change Password Use Change Password to change the password for a specific Maintenance badge. Step

Display

Action

1

Maintenance Mode idle display

Press the More... soft key three times.

2

Maintenance Mode display

Press the Change Password soft key.

2

Old Password

Type the old password for the badge.

3

New Password

Type the new password.

4

Verify Password

Type the new password a second time.

FACTORY DEFAULT Use FACTORY DEFAULT to set the Series 4000 timeclock back to the factory defaults.

Warning Only use the FACTORY DEFAULT settings if your Series 4000 timeclock is not operating properly. You lose all settings and data if you complete this transaction.

Step

Display

Action

1

Maintenance Mode idle display

Press the FACTORY DEFAULT soft key.

2

FACTORY DEFAULT?

Do one of the following: ! !

3

Press ENTER to accept the default answer. Press the toggle soft keys to select YES or NO, and press ENTER.

Communication Settings Restore your Communication Settings. See display “Communication Setting (basic configuration)” on page 4-47.

Series 4000 Badge Timeclock User’s Guide

4-57

Page 106

Chapter 4

Maintaining the Timeclock

Delete All Punches Use Delete All Punches to delete all punches from the FIFO to correct the last punch invalid error. For more information, see “Error 04-2: Last punch invalid” in Chapter 6 on page 6-3. After performing the Delete All Punches transaction, the timeclock contains only home employee data associated with schedule enforcement.

Caution Performing Delete All Punches causes all transactions stored in the FIFO (collected and uncollected) to be deleted.

Step

Display

Action

1

Maintenance Mode idle display

Press the More... soft key three times.

2

Maintenance Mode display

Press the Delete All Punches soft key.

2

Delete all punches?

Do one of the following: ! !

Press ENTER to accept the default answer. Press the toggle soft keys to select YES or NO, and press ENTER.

Restart Use Restart to restart the Series 4000 timeclock. Step

Display

Action

1

Maintenance Mode idle display

Press the Restart soft key.

2

Restart?

Do one of the following: ! !

4-58

Press ENTER to accept the default answer. Press the toggle soft keys to select YES or NO, and press ENTER.

ADP, Inc.

Page 107

Chapter 5

Upgrading Timeclock Firmware

This chapter contains the following section: !

Overview of a Softload

!

Performing a Softload

Page 108

Chapter 5

Upgrading Timeclock Firmware

Overview of a Softload A communication protocol between Data Collection Manager (DCM) and the Series 4000 badge timeclock initiates and controls the softload process. The timeclock displays a message indicating that a softload is in progress. All user input is disabled. DCM performs a Batch first-in-first-out (FIFO) command to collect all uncollected punches from the FIFO database before the download process begins.

Note Before attempting to upgrade the firmware in your Series 4000 timeclock, check with your ADP TLM Representative or the customer support section of www.adp.com for the latest firmware information.

5-2

ADP, Inc.

Page 109

Performing a Softload

Performing a Softload Before you perform a softload, you should verify that the Data Collection Manager (DCM) Collection Agent is working. The softload process does not start until the Collection Agent completes the collection process.

Caution To ensure a successful softload, do not reboot the timeclock while it is in Softload Mode. To perform a softload, do the following: 1. Access the DCM Device Manager application. 2. Select Tools > Advanced Device Manager. 3. Select a device or device group in the left pane of the Advanced Device Manager window. 4. Select Device > Load Firmware. 5. In the Load Firmware Name dialog box, do the following: a. In the File of types textbox, select .krm. b. Browse to select the appropriate .krm file. c. Click Open. You can view the status of the softload process in the Request Status window in Advanced Device Manager. When the softload process is complete, you need to initialize your timeclock. For more information about initializing a timeclock, see the Data Collection Manager System Administrator’s Guide.

Series 4000 Badge Timeclock User’s Guide

5-3

Page 110

Chapter 5

5-4

Upgrading Timeclock Firmware

ADP, Inc.