Chapter 6
Error Messages and Troubleshooting Procedures
This chapter provides error and status messages to help isolate the source of malfunctions that occur while the Series 4000 timeclock is operating. It includes the following sections: !
Error Messages - Includes descriptions and solutions for all errors that can be displayed at the timeclock
!
Troubleshooting - Includes procedures for diagnosing and resolving error conditions, communication, and operational problems
Page 112
Chapter 6
Error Messages and Troubleshooting Procedures
Error Messages The Series 4000 timeclock displays two types of messages that can provide helpful information when you are troubleshooting timeclock malfunctions: !
Error Messages
!
Status Messages
This chapter contains all of the error and status messages that the Series 4000 timeclock can display. It also describes the possible causes of the error message.
Transaction Error Messages These error conditions are found after a transaction is completed. Error 01-1: Error reading badge barcode The timeclock was able to detect that a badge was swiped, but the data on the badge could not be decoded into a barcode. It is possible that the barcode symbology is disabled. Swipe the badge again. Enable the barcode symbology if applicable. Error 02-1: Unrecognized badge format The timeclock was able to decode the data on the badge, but the barcode does not match any of the associated formats. The Series 4000 timeclock accepts only ADP standard badges; any other badge formats (generic barcode badges) must be identified via your host application software. Each step in a transaction has its own set of badge formats, so while the badge format might be known by the timeclock, it is possible it cannot be used for a specific step in a transaction. Re-enter using a different badge.
6-2
ADP, Inc.
Page 113
Error Messages
Error 04-1: Punch rejected The timeclock has detected that the time span since the last punch for this employee does not meet the minimum time between punches. The minimum time is configured using your host application software. Wait the appropriate amount of time, then punch again. Error 04-2: Last punch invalid The date and time of the last punch for this employee is in the future, making schedule enforcement impossible. Perform a Delete All Punches transaction in Maintenance Mode. For more information, see “Delete All Punches” in Chapter 4 on page 4-58. If data was already collected from the timeclock, you need to correct the data in the host application. Error 05-1: Punch rejected (xxx) Schedule enforcement logic has determined that the employee cannot punch. This error includes a reason (xxx) for the rejection. Values include: 101 - Schedule enforcement is disabled but a repunch error was detected 102 - The restriction profile the employee is assigned to is not available (not downloaded by DCM) 103 - The generic schedule the employee is assigned to is not available (not downloaded by DCM) 104 - The last punch is in the future (see Error 04-2) 105 - Repunch error (see Error 04-1) 106 - An error was found in the data in the generic schedule the employee is assigned to
Series 4000 Badge Timeclock User’s Guide
6-3
Page 114
Chapter 6
Error Messages and Troubleshooting Procedures
107 - According to the employee's generic schedule, it is a punch off time 108 - The employee is attempting to start a new shift but an individual or generic schedule cannot be found 109 - The employee is attempting to punch before a scheduled start time but earlier than is allowed (early start restriction) 110 - The employee is attempting to punch after the schedule start time but later than is allowed (late start restriction) 111 - The employee is attempting to punch after the schedule end time but later than the maximum time specified in the pay rules (late end restriction) Do one of the following: !
Swipe the employee badge while the timeclock is in Supervisor Mode.
!
Enable a single or global restriction credit from Supervisor Mode.
Error 06-1: Valid for home employees only This transaction can only be performed by home employees, but the employee badge does not match any of the home employees loaded in the timeclock. Perform this transaction with a home employee badge. Error 06-2: Unknown home employee The employee badge does not match any of the home employees loaded in the timeclock and punching by non-home employees is not allowed. Do one of the following:
6-4
!
In the host application, add the employee to the timeclock group and use the host application software to update the timeclock.
!
In the host application software, allow non-home employees to punch.
!
Swipe the employee badge while the timeclock is in Supervisor Mode.
!
Enable a single or global restriction credit from Supervisor Mode.
ADP, Inc.
Page 115
Error Messages
Error 08-1: Invalid restriction level The employee badge does not match any of the home employees loaded in the timeclock, punching by non-home employees is allowed, but not for the restriction level encoded on the badge. Do one of the following: !
In your host application software, allow the restriction level to be used by non-home employees.
!
Swipe the employee badge while the timeclock is in Supervisor Mode.
!
Enable a single or global restriction credit from Supervisor Mode.
Error 09-1: Invalid for home employees The employee badge matches a home employee loaded in the timeclock but this transaction can only be performed by non-home employees. Do one of the following: !
Re-enter the badge number.
!
Enable a single or global non-home restriction override from Supervisor Mode.
Error 36-1: System cannot save data - Contact supervisor An error was detected when the transaction was being written into the database. All activity at the timeclock will be suspended. Contact your TLM Representative. Error 41-1: Restriction profile not found The restriction profile the employee is assigned to is not available. Using your host application software, re-initialize the timeclock.
Series 4000 Badge Timeclock User’s Guide
6-5
Page 116
Chapter 6
Error Messages and Troubleshooting Procedures
Error 41-2: Generic schedule not found The generic schedule the employee is assigned to is not available. Using your host application software, re-initialize the timeclock. Error 41-3: Generic schedule not valid An error was found in the data in the generic schedule the employee is assigned to. Using your host application software, re-initialize the timeclock. Error 95-1: Password is incorrect An invalid password has been entered for the supervisor or maintenance badge. Enter the correct password.
Other Error Messages Data Error Messages Data error conditions are detected when you enter the data for a step in a transaction. These are format and content validation errors. The user must correct the rejected data in order to complete the step. These messages appear at the top of the display and the rest of the screen remains the same. The data error messages are:
6-6
!
75-1: Enter valid data
!
91-1: This field is required
!
92-1: Maximum value is xx
!
92-2: Minimum value is xx
!
93-1: Enter a numeric value
ADP, Inc.
Page 117
Error Messages
!
94-1: Enter a valid date
!
94-2: Enter a valid time
!
94-4: Enter xx digits after decimal
!
94-5: Enter data in decimal format
!
94-6: Badge data exceeds field length
!
94-7: Enter a valid IP address
!
94-8: Enter valid data
!
96-1: Maximum length is xx
!
96-2: Minimum length is xx
!
10-1: Unrecognized barcode
!
10-2: Use keypad to enter data
Transaction Error Conditions Transaction error conditions are detected after you enter all the data for a transaction. This is called transaction validation. You must correct all of the data in order to complete the transaction. The transaction error conditions are: !
91-2: Complete all fields
!
92-3: Maximum days in future is xx
!
92-4: Maximum days in past is xx
!
Effective date must be today or earlier
!
Error: The override ends in the past
Series 4000 Badge Timeclock User’s Guide
6-7
Page 118
Chapter 6
Error Messages and Troubleshooting Procedures
Status Messages The Series 4000 timeclock displays status messages that provide information, such as current mode of operation and FIFO status. !
Supervisor Mode
!
Maintenance Mode
!
Database is nearly full
!
Soft Load Mode
Supervisor Mode The timeclock is operating in Supervisor Mode. Maintenance Mode The timeclock is operating in Maintenance Mode. Database is nearly full The timeclock has reached the FIFO Nearly Full condition. Using your host application software, collect the punches from the timeclock. Soft Load Mode The timeclock is operating in Soft Load Mode. Text is visible showing the status of the soft load.
6-8
ADP, Inc.
Page 119
Troubleshooting
Troubleshooting This section provides troubleshooting procedures to help you isolate the source of hardware malfunctions that can occur while operating the Series 4000 timeclock. Troubleshooting procedures are provided for the following types of problems: !
Timeclock Hardware Failures
!
Troubleshooting Table
!
Verifying the Integrity of the Network
For diagnostic testing, refer to “What Are the Maintenance Functions?” on page 4-43.
Timeclock Hardware Failures Since error messages do not appear for most hardware failures, you must perform some hands-on troubleshooting to determine their causes. You need the following tools to troubleshoot the Series 4000 timeclock’s hardware: !
#0, #1, and #2 Phillips screwdrivers
!
1/8-inch and 1/4-inch flat blade screwdrivers
!
A nonmetallic pointed tool
!
5-32 security-head Allen wrench
!
AC/DC voltmeter
!
Ohmmeter
Series 4000 Badge Timeclock User’s Guide
6-9
Page 120
Chapter 6
Error Messages and Troubleshooting Procedures
You also need the following functioning elements of the front cover assembly. For part numbers, see “Replacing the Backup Battery Charger Board” on page 4-24. !
LCD display assembly
!
DC wall transformer
!
Keypad
!
Auxiliary power source (APS)
!
Remote swipe bar code badge reader
!
Ethernet option board
Troubleshooting Table The following table summarizes the steps that you should follow when troubleshooting the Series 4000 timeclock’s hardware. For additional information, contact your TLM Representative. Symptom
Probable Cause
Corrective Action
Make sure cable is connected to the The power LED is Display’s cable is not connected to mainboard. mainboard. turned on, but nothing appears on Display board is Replace the front cover assembly. Contact the screen. malfunctioning. your TLM Representative.
6-10
Mainboard is malfunctioning.
Replace the Field Replaceable Unit (FRU). Contact your TLM Representative.
Run the Display Test.
1. Access Maintenance Mode. 2. Press the More soft key. 3. Press the Display Test soft key. 4. Press ENTER to start the test and note the result. 5. Contact your TLM Representative.
ADP, Inc.