Page 121

Troubleshooting

Symptom

Probable Cause

Corrective Action

The Series 4000 timeclock does not power up, and the power LED is not turned on.

The transformer is not plugged in properly to the timeclock’s main board, the AC outlet, or both.

Check the connections to the main board and the AC outlet. Important: If the power cord is not plugged into the AC outlet, do not plug it in until you ensure that the transformer is properly connected to the main board. For instructions, see “Supplying Power to the Timeclock” in the Series 4000 Badge Timeclock Installation Guide.

Power LED is off

No power available to AC outlet.

Restore power.

While running on backup battery power, the backup battery expired.

Restore power via AC outlet.

Poor connection to the main board.

Check the connections to the main board.

Bad cable.

Replace cable. Contact your TLM Representative.

Power supply is bad.

Replace power supply. See “Replacing the AC Power Supply (transformer)” in Chapter 4 on page 4-40.

LED indicator light is burned out.

Replace the front cover assembly. Contact your TLM Representative.

Run the LED test.

1. Access Maintenance Mode. 2. Press the More soft key. 3. Press the LED Test soft key. 4. Press ENTER to start the test and note the result. 5. Contact your TLM Representative.

Series 4000 Badge Timeclock User’s Guide

6-11

Page 122

Chapter 6

Error Messages and Troubleshooting Procedures

Symptom

Probable Cause

Corrective Action

Adjust the contrast and brightness of the No LCD backlight The contrast and brightness of the display display screen. See “Display Setting (basic configuration)” on page 4-49. screen are not appropriate for the timeclock’s environment. Keypad fails to work

Lead-acid battery failure

The keypad’s ribbon If you can, determine the exact nature of cable is improperly the problem (for example, is the cable connected to mainboard. twisted or cut?), then contact your TLM Representative. Run the Keypad test.

1. 2. 3. 4. 5. 6.

Access Maintenance Mode. Press the More soft key. Press the Keypad Test soft key. Type various keys on the keypad. Note which key or keys fail to work. Contact your TLM Representative.

The battery backup option is improperly installed.

Reinstall according to specifications.

Replace with functioning battery backup Battery backup board battery-charging circuit board. Contact your TLM Representative. is not functioning properly.

6-12

Battery is defective.

Replace with a functioning battery. Contact your TLM Representative.

Poor connections.

Check connections.

ADP, Inc.

Page 123

Troubleshooting

Symptom

Probable Cause

Corrective Action

Series 4000 timeclock fails to read badges.

The badge is unreadable 1. Inspect the badge for cleanliness. 2. Clean the badge and badge reader. or does not meet the required badge specification. PIN punching only is enabled.

Using Data Collection Manager (DCM), enable badge punching.

The bar code on the badge is worn or scraped off.

Replace the badge.

1. Access Maintenance Mode. You did not configure the timeclock to read the 2. Press the Symbology Setting soft key. 3. Turn on the appropriate symbology. symbology encoding your badges use. The timeclock is not enabled for the correct badge reader type or company ID code (if you are using a code).

Using Data Collection Manager (DCM), correct the badge reader and company ID code settings.

The badge reader may not be working correctly.

Run the Badge Test test: 1. Access Maintenance Mode. 2. Press the More soft key to display the test functions. 3. Press the Badge Test soft key. 4. Follow the prompts to conduct the test and note the result. If the test does not indicate a problem, run a Reader Report: 1. Access Maintenance Mode. 2. Press the More soft key twice. 3. Press the Reader Report soft key. Note the report results and contact your TLM Representative.

Series 4000 Badge Timeclock User’s Guide

6-13

Page 124

Chapter 6

Error Messages and Troubleshooting Procedures

Symptom

Probable Cause

Corrective Action

Communication fails.

Communication settings To check settings at the timeclock: are incorrect either at 1. Access Maintenance Mode. the timeclock or the host 2. Press the Communication Settings soft PC. key. 3. Check and, if necessary, correct the Device ID, IP Address, Gateway, and Subnet Mask settings. If communication continues to fail, check the communication settings at the host PC. Refer to the documentation for your ADP host application. Communications cabling is connected incorrectly.

Ensure that all communications cables are routed correctly and connected properly. If the connections are secure, determine whether the cable is defective by doing the following: !

Check to see if the green communications LED on the Series 4000 timeclock is lit. Use the security wrench to unlock and open the cover of the timeclock. The green LED is located inside the cover and to the left of the Ethernet connection on the main board. ! Check to see if the green link light on the hub to which the timeclock is connected. If both lights are lit, the cable is not defective. The problem may lie in the network configuration. If both lights are not lit, the cable may be defective. Consult with your system administrator to resolve the problem.

6-14

Poor connections.

Check connections.

Bad mainboard.

Replace the Field Replaceable Unit (FRU). Contact your TLM Representative.

ADP, Inc.

Page 125

Troubleshooting

Verifying the Integrity of the Network Verify the integrity of the Series 4000 timeclock’s communications capabilities by following these steps: 1. Perform a general inspection of the installation site. Ensure that all communications cables are routed properly and are securely connected to the timeclock(s), the host PC, and any other ADP equipment that may be installed at the site. 2. Inspect the cables. Make sure they are properly attached. 3. Check wires for any breaks. 4. Using a lap top connected to the Series 4000 timeclock’s Ethernet external jack, PING the host PC. If there are any communication problems, take appropriate action to resolve them. For more information, contact your TLM Representative.

Series 4000 Badge Timeclock User’s Guide

6-15

Page 126

Chapter 6

6-16

Error Messages and Troubleshooting Procedures

ADP, Inc.

Page 127

Appendix A

Timeclock Specifications

Case:

Black, advanced polycarbonate/ABS resin, dust and moisture-resistant

Dimensions:

Width: 10.75 inches (27.30 cm) Height: 11.75 inches (29.85 cm) Depth: 4 inches (10.16cm)

Weight:

5 lbs. (2.25 kg)

Keypad:

Silicon Elastomer numeric keypad and 8 programmable soft keys

Power Supply:

50/60 Hz 110/220 V transformer

Power requirements:

100 to 240V, 1.5A maximum

Display:

4 x 40 FSTN LCD

Host communications:

10/100 Mbit auto-sensing Ethernet

CPU:

Motorola MPC 860DT

Memory:

16 MB RAM, upgradeable to 64 MB 8 MB Flash, ability to upgrade to 100 MB

Badge Reader:

Integrated bar code badge reader

Battery Backup:

Optional, 12 VDC lead acid battery to provide the timeclock up to two hours of full functioning operation

Operating Environment: Temperature: 0 to 40o Celsius (32 to 104o Fahrenheit) Humidity: 10% to 95% non-condensing Shock:

Withstands 40 Gs of force when packed in original shipping carton

ESD Protection:

Withstands 20 kV electrostatic discharge without failures

Page 128

Appendix A

A-2

Timeclock Specifications

AC Surge Protection:

Timeclock withstands AC power surges induced by lightning, the local power company, or inductive switching transients as tested in accordance with IEEE Standard 587

FCC:

Meets all Federal Communications Commission (FCC) requirements for Class A computing device

Approvals:

Underwriter’s Laboratories (UL) Canadian Standards Association (CSA)

ADP, Inc.

Page 129

Appendix B

Differences Between the Series 4000 and the Series 400 Timeclocks

This appendix contains information about the differences between the Series 400 timeclocks and the Series 4000 timeclock. This appendix contains the following sections: !

Physical Differences

!

Functional Differences

Page 130

Appendix B

Differences Between the Series 4000 and the Series 400 Timeclocks

Physical Differences The following table shows the physical differences between the Series 4000 and the Series 400 timeclocks.

Display

B-2

Series 4000

Series 400

4.7”, 1/4 VGA LCD

2 X 20 LCD

Configurable soft keys 14 Employee Mode using DCM 14 Supervisor Mode

Used command numbers to perform functions

Device message length 40 character

20 characters

Host communications 10/100 Mbit auto-sensing Ethernet

N/A

Memory

128 kilobytes up to 256 kilobytes

16 MB RAM, upgradeable to 64 MB 8 MB Flash, ability to upgrade to 100 MB

ADP, Inc.