Page 71

Servicing the Timeclock

9. Press ENTER to save the settings and return to the Maintenance Mode screen. 10. Press the Symbology Setting soft key and use the On and Off soft keys to indicate the type of bar codes used on your employees’ badges. This allows the timeclock to read the badges properly. Symbology Setting Code 3-of-9: 12-of-5: UPC-A: UPC-E: Code 128: EAN-8: EAN-13: Codabar:

Off On Off Off Off Off Off Off

On

Off

11. Press ENTER to save the settings and return to the Maintenance Mode screen. 12. To create a password that allows access to the Maintenance Mode screen in the future, press the More soft key and then the Change Password soft key. Complete the following fields: Settings

Description

Old Password

Enter the old password, if there was one.

New Password

Enter the new password.

Verify Password

Enter the new password again to verify that you entered it correctly.

13. Press ENTER to save the password and return to the Maintenance Mode screen. 14. Press ESC to exit Maintenance Mode and return to the idle screen.

Series 4000 Badge Timeclock User’s Guide

4-23

Page 72

Chapter 4

Maintaining the Timeclock

Replacing the Backup Battery Charger Board 1. Before you begin, collect data from the timeclock using your host application software. For more information, see the “Using the Host Application Software to Collect Data” section on page 4-10. 2. Open the timeclock’s cover by using the security wrench to loosen the security screw on the right side of the timeclock. 3. To disconnect and remove the battery charger board, you must first remove the transformer. Do the following: a. Unplug the transformer from the AC power source. If you plugged the timeclock into an external outlet, disassemble the strain relief clip at the power cord’s point of entry into the timeclock. See the following illustration.

4-24

ADP, Inc.

Page 73

Servicing the Timeclock b. Unplug the power cord from the transformer. c. Disconnect the transformer cable from the timeclock’s main board.

Number

Description

1

Transformer cable

2

Hooks holding the cable in place

3

Transformer connection to the main board (DC power)

d. Trace the wire back to the transformer, freeing it from the hooks molded into the base of the timeclock.

Series 4000 Badge Timeclock User’s Guide

4-25

Page 74

Chapter 4

Maintaining the Timeclock e. Lift the transformer from behind the wire clip, and out of the timeclock.

4-26

ADP, Inc.

Page 75

Servicing the Timeclock

4. Disconnect the battery charger board from the timeclock’s main board.

Number

Description

1

Battery charger board cable

2

Charger board connection to the main board

5. Trace the wires back to the charger board.

Series 4000 Badge Timeclock User’s Guide

4-27

Page 76

Chapter 4

Maintaining the Timeclock

6. Disconnect the battery charger board from the positive and negative terminals of the backup battery.

4-28

Number

Description

1

Hooks molded into the base

2

Negative terminal connection

3

Positive terminal connection

ADP, Inc.

Page 77

Servicing the Timeclock

7. Loosen the screw in the center of the battery charger board and remove the board from the timeclock.

Mlinst38

8. Unplug the cables from the connectors on the charger board. 9. Plug the cables into the connectors on the new charger board. Match the ends of each cable with the appropriate pin connector on the charger board.

10. Re-install the battery charger board into the timeclock. 11. Reconnect the wires from the charger board to the battery terminals.

Series 4000 Badge Timeclock User’s Guide

4-29

Page 78

Chapter 4

Maintaining the Timeclock

12. Position the transformer back into place behind the wire clip, route the cable back to its connection on the main board, and plug in the cable.

4-30

Number

Description

1

Transformer cable

2

Hooks for routing the cable

3

Transformer connection to the main board (DC power)

ADP, Inc.

Page 79

Servicing the Timeclock

13. Route the charger board cable back to its connection on the main board and plug in the cable.

Number

Description

1

Battery charger board cable

2

Charger board connection to the main board

14. Plug the transformer back into the AC power source. 15. Test the battery backup by watching the amber LED on the front of the Series 4000 timeclock. When you remove AC power while the battery backup option is installed, the amber LED flashes on and off, indicating that the timeclock is being powered by battery. When you restore AC power, the LED lights continuously.

Series 4000 Badge Timeclock User’s Guide

4-31

Page 80

Chapter 4

Maintaining the Timeclock

Adjusting the Width of the Badge Reader Slot Removing the Reader Spacers If you did not remove the spacers before you installed the Series 4000 timeclock, you need to perform the following procedure to remove them from the back of the timeclock: 1. Before you begin, collect data from the timeclock using your host application software. For more information, see the “Using the Host Application Software to Collect Data” section in this chapter. 2. Open the timeclock’s cover by using the security wrench to loosen the security screw on the right side of the timeclock. 3. Unplug the transformer from the AC power source. If you plugged the timeclock into an external outlet, disassemble the strain relief clip at the power cord’s point of entry into the timeclock.

4. Unplug the power cord from the transformer.

4-32

ADP, Inc.