The text of a manual · part 7 of 15
User's Guide: Series 4000 Badge Timeclock, pages 61 to 70
Pages 61 to 70 of 146
The original document is the PDF (1.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Kronos System 4500
Page 61
Servicing the Timeclock
4. Locate and remove the two screws on the left side of the base. See the following illustration. Keep the screws in a safe place.
5. While supporting the cover with one hand, squeeze the two clips shown in the following illustration to release the hinge clip holding the cover in place.
Series 4000 Badge Timeclock User’s Guide
4-13
Page 62
Chapter 4
Maintaining the Timeclock
6. Separate the cover from the base.
Number
Description
1
Recessed areas in the base where the hinges were seated
Returning the Cover Assembly When you return the cover assembly to ADP for any reason, you must use the original ADP carton in which it was shipped.
4-14
ADP, Inc.
Page 63
Servicing the Timeclock
Attaching the Cover Assemby to the Timeclock 1. Release the plastic hinge clip by squeezing the retainers at each hinge position. You can squeeze each retainer one at a time or simultaneously until you feel the clip release.
2. Rotate the hinge clip to the left.
Series 4000 Badge Timeclock User’s Guide
4-15
Page 64
Chapter 4
Maintaining the Timeclock
3. Fit the two hinges on the cover into the corresponding areas molded in the base.
4-16
Number
Description
1
Recessed areas in the timeclock base for seating the hinges
ADP, Inc.
Page 65
Servicing the Timeclock
4. Carefully close the cover of the timeclock, making sure that the two hinges remain properly seated in place.
Caution After the cover is closed, continue to hold it securely in place as you perform the next step.
Series 4000 Badge Timeclock User’s Guide
4-17
Page 66
Chapter 4
Maintaining the Timeclock
5. Rotate the hinge clip forward until it snaps into place.
6. Open the cover and install the two small, flat (not pointed) screws to secure the hinge clip, as shown in the following illustration.
4-18
ADP, Inc.
Page 67
Servicing the Timeclock
7. Reconnect the cables inside the timeclock and plug in the power cable. If necessary, refer to the Series 4000 Badge Timeclock Installation Guide that you received with your timeclock. When the Series 4000 timeclock is initialized and the Communication Setting screen appears, go to “Performing Basic Configuration at the Series 4000 Timeclock” on page 4-20 to perform basic configuration at the timeclock.
Series 4000 Badge Timeclock User’s Guide
4-19
Page 68
Chapter 4
Maintaining the Timeclock
Performing Basic Configuration at the Series 4000 Timeclock Whenever you restore the Series 4000 timeclock to the factory defaults, you must complete the basic configuration settings on the timeclock before you can restore the timeclock’s overall configuration from the host application. When the Series 4000 timeclock is first powered on and initializes (“boots up”), the Communications Setting screen appears: Changing comm settings causes a reboot! Device ID IP Address Gateway Subnet Mask
1. On the Communication Setting screen, complete the following fields, with the help of your network administrator:
4-20
Settings
Description
Device ID
Enter an ID number (at least six digits) for the timeclock. The host application uses this number to identify the timeclock.
IP Address
Enter the IP address, including the periods, assigned to the timeclock by your system administrator.
Gateway
Enter the IP address, including the periods, of the default device that forwards data to the host application. This field holds up to 15 digits.
Subnet Mask
Specify a number that identifies a subnetwork so that an IP address can be found on a LAN. This field holds up to 15 digits.
ADP, Inc.
Page 69
Servicing the Timeclock
2. Press ENTER at the last prompt. The timeclock reboots itself so that the new communications settings take effect, and then the idle screen appears:
2:03
PM
Fri 17–Aug–2001
3. Swipe the Maintenance badge that came with the Series 4000 timeclock (the badge has an “M” on the front). To do this, hold the badge so that the bar code is positioned on the back left edge and swipe the badge up or down through the reader’s slot. The Maintenance Mode menu screen appears:
2:03
PM
Fri 17–Aug–2001 Maintenance Mode
Comm Setting
Symbology Setting
Display Setting
Restart
Audio Setting
FACTORY DEFAULT
Date/Time Setting
More...
Series 4000 Badge Timeclock User’s Guide
4-21
Page 70
Chapter 4
Maintaining the Timeclock
4. To change the current appearance of text on the screen, press the Display Setting soft key and complete the following fields. To quickly set a field to its minimum value, press CLR. Settings
Description
Contrast
Use the + and - keys indicated at the bottom of the screen to increase or decrease the degree of difference between light and dark extremes of color on the timeclock’s display. The minimum value is 16; the maximum value is 22.
Brightness
Use the + and - keys indicated at the bottom of the screen to increase and decrease the brightness of the timeclock display.
5. Press ENTER to save the settings and return to the Maintenance Mode screen. 6. To change, enable, or disable the key click, or adjust the beeper volume, press the Audio Setting soft key and complete the following fields: Settings
Description
Beeper volume Use the + and - keys indicated at the bottom of the screen to increase and decrease the degree of beeper volume. The minimum value is 1; the maximum value is 7. Key click
Use the Off and On keys indicated at the bottom of the screen to enable or disable the key click sound. The Off/On choices appear when you position the cursor in this field.
7. Press ENTER to save the settings and return to the Maintenance Mode screen. 8. Press the Date/Time Setting soft key and enter the current date and time using the indicated format. Settings
Description
Date (mm/dd/yyyy) Enter the current month, day, and year. For the year, enter all four digits. Do not enter the slashes. Time (24 hour)
4-22
Enter the current time of day in 24-hour format. Do not enter the colon. For example, enter 1730.
ADP, Inc.