Page 51
Maintenance Basics
Safety Considerations The Series 4000 timeclock is approved by Underwriter’s Laboratories (UL), the Canadian Standards Association (CSA), and the Federal Communications Commission (FCC), and ships from the factory in a safe condition.
Warning This chapter contains information that you must follow to ensure safe operation and maintenance of the timeclock. Failure to follow a warning statement can result in personal injury.
Handling Static-Sensitive Components Many assemblies in the Series 4000 timeclock have static-sensitive components. Static electricity can cause hardware components to fail. Use the ADP Field Service Anti-Static Kit (part number 3600166-001) when handling static-sensitive assemblies. You can damage components if you do not take the following precautions: !
When handling a static sensitive assembly for any reason, first put on the Anti-Static Kit’s wrist strap. Wrap the conductive wrist strap around your wrist so that it is comfortable, and secure the fastener. Be sure the other end of the strap is grounded.
!
When you finish handling the assembly, replace it in the Series 4000 timeclock, or place it on a grounded conductive surface.
Series 4000 Badge Timeclock User’s Guide
4-3
Page 52
Chapter 4
Maintaining the Timeclock
Obtaining Replacement Parts The following listing shows the parts that you can order for the Series 4000 timeclock. To order a part, contact your TLM Representative.
4-4
Part Number
Description
8900052-001
Anchors, 3
8601763-001
Backup battery
9600015-001
Badge reader cover
6800134-001
Badges, maintenance
6800133-001
Badges, supervisor
9600020-001
Hinge
9000104-001
Hinge screws, 2
8601824-001
Internal AC outlet
9600016-001
I/O panel
9000151-001
Mounting screws, 3
7200200-001
Power cord, 6-foot
7200201-001
Power cord, 12-inch
8400408-001
Power cord strain relief clip
9100200-001
Power cord strain relief nuts, 2
9000203-001
Power cord strain relief screws, 2
8900018-001
Security wrench
8400428-001
Square cable plate
9100104-001
Square cable nuts, 2
7800102-001
Transformer
8400433-001
Transformer holder
ADP, Inc.
Page 53
Preventive Maintenance
Preventive Maintenance The Series 4000 timeclock requires periodic preventive maintenance to ensure trouble-free operation. ADP recommends that you perform preventive maintenance at least once a year, depending on the environment in which the timeclock is used.
Cleaning the Timeclock Keep the Series 4000 timeclock case and badge reader clean to prevent dirt and grease from obscuring the LCD display or getting inside the badge reader. To clean the timeclock’s case and keyboard: 1. Using a soft, lint-free cloth, and a spray bottle of glass cleaner, clean the outside of the Series 4000 timeclock’s cover and case. Do not spray the cleaner inside the timeclock’s case. When cleaning the timeclock’s case, spray the cleaner on the cloth - do not spray the cleaner directly on the timeclock. 2. Clean the polycarbonate lens that covers the timeclock’s display. Do not use steel wool or any other abrasives, or solvents such as alcohol, benzene, or acetone, as they can damage the timeclock. To clean the badge reader: 1. Fold a paper towel over an inactive badge. 2. Spray the towel gently with a glass cleaner. 3. Swipe the badge several times in the badge reader.
Series 4000 Badge Timeclock User’s Guide
4-5
Page 54
Chapter 4
Maintaining the Timeclock
About the Lithium and Lead Acid Batteries This section describes the two types of batteries used by the Series 4000 timeclock. Each Series 4000 timeclock is equipped with a lithium battery. As an option, you can also install a lead acid battery for backup power in the event of a power outage.
Note Be sure to check all local and national regulations pertaining to the proper storage and disposal of batteries.
Lithium Battery The lithium battery is a 3 VDC battery that powers the timeclock’s internal realtime clock if external power is lost. You cannot perform any timeclock operations while the timeclock is operating on lithium battery backup. You should replace the lithium battery when it is 3 years old or if the date and time do not reset correctly after a power failure. To replace the lithium battery, do the following: 1. Open the timeclock’s cover by using the security wrench to loosen the security screw on the right side of the timeclock. 2. Use a nonmetallic pointed tool to remove the lithium battery. 3. Install the new lithium battery. 4. Close and lock the timeclock cover using the security wrench.
4-6
ADP, Inc.
Page 55
Preventive Maintenance
Lead Acid Battery The lead acid battery is an optional 12-VDC backup battery that you can order separately. The lead acid battery provides up to two hours of full functionality in the event of a power failure, including support of: !
Full LCD display (backlight automatically dimmed)
!
Badge reader
!
Keypad entries
!
Ethernet communications
You should replace the backup battery when it is 4 years old. When you order a new backup battery, you also receive an installation guide.
Note It takes 24 hours for the Series 4000 timeclock to recharge the backup battery after the backup battery has been completely depleted.
Running Diagnostic Tests and Reports You can run diagnostic tests and reports to test parts of the timeclock or to get specific information about the timeclock. For more information about diagnostic tests and reports, see the “What Are the Maintenance Functions?” section beginning on page 4-43.
Series 4000 Badge Timeclock User’s Guide
4-7
Page 56
Chapter 4
Maintaining the Timeclock
Servicing the Timeclock Servicing the Series 4000 timeclock consists mainly of checking status, configuring the timeclock, testing components, and removing and replacing malfunctioning components of the timeclock. Depending on the nature of the problem you are having with the timeclock, you will do one of the following: !
Send the front cover assembly back to ADP, Inc. Do this if there is something wrong with the main board of the timeclock, or you and your TLM Representative cannot readily identify the problem with the timeclock. See the “Returning the Cover Assembly to ADP” section on page 4-10 in this chapter for detailed instructions.
!
Obtain a replacement part. Examples of replacement parts are the transformer, backup battery, and badge reader cover. See the “Replacing the Backup Battery Charger Board” section on page 4-24 in this chapter for a complete list of parts and the procedure for ordering parts.
Caution Before servicing the Series 4000 timeclock, save its data by using your host application software to collect the data. For more information about collecting data, see the “Using the Host Application Software to Collect Data” section on page 4-10.
4-8
ADP, Inc.
Page 57
Servicing the Timeclock
Interior of Fully-Assembled Timeclock The following figure shows the interior of the Series 4000 timeclock:
Number
Description
1
Battery charger board connection to the main board (if the backup battery is installed)
2
Transformer connection to main board
3
Ethernet connection to main board
4
Backup battery (optional)
5
Transformer
6
Ethernet cable (shown run through the wall and into the timeclock)
7
AC power cable
8
Battery charger board (if the backup battery is installed)
9
Cables for the transformer and battery charger board (optional) routed to their connection points on the main board (see numbers 1 and 2)
Series 4000 Badge Timeclock User’s Guide
4-9
Page 58
Chapter 4
Maintaining the Timeclock
Returning the Cover Assembly to ADP If the mainboard of the Series 4000 timeclock is not operating properly or you and your TLM Representative cannot identify a problem with the timeclock, you need to return the front cover assembly to ADP for repair or replacement. The front cover assembly includes the following major components: !
Main board
!
Badge reader and cover
!
DC power supply
!
Keypad
!
Keypad membrane
!
Liquid crystal display (LCD)
Using the Host Application Software to Collect Data Before you remove the front cover, use your host application software to collect all data. If your host application is eTIME, you use its data collection timeclock communication feature (Commlink application) to collect data. For more information about this process, see the eTIME System Manager Guide and the eTIME online Help. If your host application is Enterprise eTIME, you use Data Collection Manager (DCM) to collect data. For more information about this process, see the DCM System Administrator’s Guide and the DCM online Help.
4-10
ADP, Inc.
Page 59
Servicing the Timeclock
Removing the Cover Assembly from the Timeclock To remove the front cover, you must disconnect the timeclock from its power source. For example, you may have to remove and replace the timeclock’s lithium battery, or replace the timeclock itself. 1. Open the timeclock’s cover by using the security wrench to loosen the security screw on the right side of the timeclock.
Number
Description
1
Security screw
2
Security wrench
2. Disconnect the transformer in the timeclock from the AC power source. Depending on how you installed the timeclock, do one of the following: !
Unplug the power cord from an AC outlet external to the timeclock.
!
If the timeclock is mounted over an AC outlet, unplug the power cord from that outlet.
!
If you used the internal AC outlet, unplug the power cord from the internal outlet.
Series 4000 Badge Timeclock User’s Guide
4-11
Page 60
Chapter 4
Maintaining the Timeclock
3. Disconnect the following cables from the main board in the order shown. Refer to the following illustration:
4-12
!
Transformer cable
!
Backup battery cable (if the backup battery is installed)
!
Ethernet cable
Number
Description
1
Disconnecting the transformer from the main board
2
Disconnecting the battery charger board from the main board (if you installed the backup battery)
3
Disconnecting the Ethernet cable from the main board
ADP, Inc.