Page 161

Chapter 5 Operation This chapter describes RUN mode and the controls available during RUN mode operation. 5.1

Entering RUN Mode ........................................................... 152

5.2

Controls Available in RUN Mode ...................................... 153

Page 162

Chapter 5

Operation

5.1 Entering RUN Mode This section describes RUN mode. Before entering RUN mode, complete the settings described in “Chapter 4 Setting Procedure”. 1. Change the PROGRAM mode to RUN mode. •

With the panel keys Hold down the [RUN/PROGRAM] key for at least two seconds. SCREEN WINDOW RUN PROG PROGRAM No.

•

With the remote control console Use one of the following two methods to enter RUN mode. • Slide up the mode selection switch to “RUN”. • Unplug the remote control console from the controller.

RUN

5

PROG

RUN ENT

Mode selection slide switch

ESCAPE

2. Once the CV-701(P)/751(P) enters RUN mode, [RUN] appears in the upper right of the screen. • •

When “ARE/CON” mode is selected, the CV-701(P)/751(P) starts and continues detection, judgment, and displaying results. When a mode other than “ARE/CON” mode is selected, the CV-701(P)/ 751(P) starts detection, judgment, and displaying results every time a trigger signal is input.

NUM NUM NUM

C S , 1 2 3 cr Note: Once the CV-701(P)/751(P) enters RUN mode, the setting operation from the remote control console or the panel keys is disabled. You can use only the [SCREEN], [TRIG], [PROGRAM No.], and [WINDOW] keys and the mode selection slide switch.

Key-lock function (CV-751(P)) When the key-lock function is activated, the operation of all keys except for the [SCREEN] and [WINDOW] keys is disabled to prevent accidental key operation. Set the key-lock function in PROGRAM mode before entering RUN mode.

▲

▲

■ To set the key-lock function Hold down the [ ] and [ ] cursor keys simultaneously for at least two seconds. When the function is activated, [KEY LOCK] appears at the bottom of the menu screen.

▲

152

▲

■ To cancel the key-lock function Hold down the [ ] and [ ] cursor keys simultaneously for at least two seconds. The display [KEY LOCK] disappears and key operation is enabled.

KEY LOCK

Page 163

Chapter 5

Operation

5.2 Controls Available in RUN Mode In RUN mode, the CV-701(P)/751(P) can be controlled using external signals through the I/O terminals and RS-232C. Mode

RUN

How to enter the mode

Available operations

Set CHANGE in the environmental setting menu to CONSOLE and then set the console’ s slide switch to “ RUN” .

Terminal/ connector

Judgment result/numerical value output Trigger (TRG) input Coordinate value X/Y selection (PST) (Only when pattern search or edge search in both the X and Y directions is set.)

156

Unplug the remote control console from the controller.

Console

Trigger input Screen selection Window No. selection for display/data output RUN/PROGRAM selection

152

Trigger input Data output

187

Send the "R0cr" RS-232C command when the CV is in communication mode. Set CHANGE in the environmental setting menu to CONSOLE and then set the console’ s slide switch to “ RUN” .

Terminal/ connector

Judgment result/numerical value output Trigger (TRG) input Coordinate value X/Y selection (PST) (Only when pattern search or edge search in both the X and Y directions is set.) Window No. selection for display/data output (Wlx)

156

Unplug the remote control console from the controller.

Console

Trigger input Screen selection RUN/PROGRAM selection

152

Send the "R0cr" RS-232C command when the CV is in communication mode.

Trigger input Data output

187

Short-circuit the REC1 Terminal/ • REC2 and COM2 connector terminals when the CV is in RUN or RUN [EXT] mode.

Screen registration (By short-circuiting the TRG and COM1 terminals.)

164

Send the "O0cr" command.

Reading/writing output setting Reading/writing setting data Reading/writing registered screen Reading/writing program number Screen registration Reading input screen Saving setting data

188

RUN (External control)

Screen registration

Communication

Reference page

RS-232C

153

5

Page 164

Chapter 5

Operation

MEMO

5

154

Page 165

Chapter 6 I/O Timing and Analog Output Explains the input/output timing and analog output. 6.1

I/O Terminal Names and Functions .................................. 156

6.2

Input/Output Timing Diagrams ......................................... 160

6.3

I/O Circuit ............................................................................ 165

6.4

Analog Output .................................................................... 166

6.4.1 Analog output terminals ....................................................... 166 6.4.2 Changing analog output settings ......................................... 166 6.4.3 Scaling the analog output .................................................... 167

Page 166

Chapter 6

I/O Timing and Analog Output

6.1 I/O Terminal Names and Functions This section describes the names and functions of I/O terminals/connectors and the position of analog output.

The position of I/O terminals I/O connector Analog output

Analog output I/O connector I/O terminal

I/O terminal

Names and functions of I/O terminals and I/O connectors ● I/O terminal Terminal No. (controller side) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Terminal No.

Signal name

1

24 VDC

24 VDC power supply input

0V

0 V for power supply input

2

6

3

Description

See the table below.

4

TRG

Trigger input for timing signal

5

See the table below.

6

See the table below.

7

WO1

Window 1 comparator output

8

WO2

Window 2 comparator output

9

WO3

Window 3 comparator output

10

WO4

Window 4 comparator output

11

WO5

Window 5 comparator output

12

WO 6

Window 6 comparator output

13

WO7

Window 7 comparator output

14

WO8

Window 8 comparator output

15

WOR

OR output of WO1 to WO8

NPN (CV-701/751) 3 5 6

Common signal (0 V) for inputs/outputs STO Strobe signal output for output Common signal (0 V) for COM1 inputs/outputs COM1

PNP (CV-701P/751P) 3 5 6

Power supply for PNP output (5 to 24 V) Common signal (0 V) for COM1 inputs/outputs V1

STO

Strobe signal output for output

COM1 terminals 3 and 6 are common.

CAUTION

156

Terminal 0 V (for power supply input), COM1, and COM2 are common via a choke coil. Be sure that there is no potential difference among the three terminals.

Page 167

Chapter 6

I/O Timing and Analog Output

Connector pin No. (controller side)

● I/O connector

16 15 14 13 12 11 10 9

8

7

6

5

4

3

2

1

32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17

Pin No.

Signal name

1

Input terminal (not to be used)

2

CI0

Program No. input 0 (LSB)

3

CI 1

Program No. input 1

Orange

4

CI 2

Program No. input 2

Yellow

CI3

Program No. input 3 (MSB)

Green

6

COM2

Common signal (0 V) for inputs/outputs

Blue

7

COM2

8

D0

Common signal (0 V) for inputs/outputs

Purple

Data output 0 (LSB)

Gray

9

D1

Data output 1

White

10

D2

Data output 2

Black

11

D3

Data output 3

Brown

12

D4

Data output 4

Red

13

D5

Data output 5

Orange

14

D6

Data output 6

Yellow

15

D7

Data output 7

Green

16

D8

Data output 8

Blue

17

D9

Data output 9

Purple

18

D1 0

Data output 10

Gray

19

D11

Data output 11

White

20

D12

Black

22

Data output 12 (MSB) Position data sign output P.POLE (output upon negative signal) See the table below.

23

See the table below.

24

PST

25

WI0

26

WI 1

27

WI 2

28

CONT

29

Brown

Data output selection input Display and output window selection input 0 (LSB) Display and output window selection input 1

Yellow

Purple

BUSY

Display and output window selection input 2 Continuous operation input (When a program is switched, continuous judgment starts without an external trigger signal.) BUSY signal output

30

REC1

Screen registration input Camera 1

Black

31

REC2

Screen registration input Camera 2

Brown

Unused terminal

Red

32

COM2 COM2

Green Blue

Gray White

PNP (CV-701P/751P)

NPN (CV-701/751)

23

Red

5

21

22

Cable color* Brown

Description

Common signal (0 V) for inputs/outputs

Red

Common signal (0 V) for inputs/outputs

Orange

22, Unused terminal

23, Unused terminal Orange

Red

COM2 terminals 6, 7, 22, and 23 are common. * The colors represent the cable colors used in the special I/O cable (option: OP35341). Data outputs (D0 to D12) are 13-bit binary outputs (negative-true logic). D0 (LSB) to D12 (MSB) signals are in one-to-one correspondence with 1.2.4.8…4096, and they read data by doing sums of the terminals that are turned on. Tips

For screen registration input TRG with the REC (1 and/or 2) input. Simultaneous inputs of REC 1/2 and CONT show the raw screen with a cross-shaped cursor in the center.

157

6

Page 168

Chapter 6

I/O Timing and Analog Output

Binary data input (Output window selection input) Input W0

W1

W2

Window No.

OFF

OFF

OFF

1

ON

OFF

OFF

2

OFF

ON

OFF

3

ON

ON

OFF

4

OFF

OFF

ON

5

ON

OFF

ON

6

OFF

ON

ON

7

ON

ON

ON

8

Binary data output format from D0 to D12 The format of binary data output varies depending on the measurement mode. Note: The data output from the terminals is not binary-converted. Mode

Sub-mode

AREA OUTER/ INNER EDGE

6

GAP/PITCH EDGE NO

COUNT POINT STAIN GRAVITY PATT EDGE MODE

PST Output data Selection Open The last 13 bits of AREA measured data. Closed

The first 13 bits of AREA measured data.

Open

Edge measurements

Closed

Edge measurements

Open

Pitch average value

Closed

Pitch average value

Open

Edge number

Closed

Edge number

Open

Count number

Closed

Count number

Open

Dn1.: Pn2. [OFF: background, ON: extraction color] 3.

Closed

The detection result of Dn1.: Pn2. [OFF: x, ON: ❍] 3.

Open

Measured data

Closed

Measured data

Open

X coordinate of the detected point

Closed

Y coordinate of the detected point

Open

X coordinate of the detected point

Closed

Y coordinate of the detected point

Open

X coordinate of the detected point

Closed

Y coordinate of the detected point

1. The nth bit of output data 2. Point n 3. 1: ON/ 0: OFF 4. The decimal point is not output. (The ten-times value of the displayed value is output.)

158

Page 169

Chapter 6

I/O Timing and Analog Output

Point sensor (Supplemental) The status of each point (extracted color/non-extracted color) is output when the PST terminal is open. The detection result of each point is output when the PST terminal is short-circuited. (Turns ON when the results agree with the [SET] of each point.) Point 1 to 8 output data corresponding to D0 to D7. P1,

P2,

...……

P8

↓ D0,

↓ D2

...……

↓ D7

● Analog output Use the special cable (OP-41420) for connection.

6

159

Page 170

Chapter 6

I/O Timing and Analog Output

6.2 Input/Output Timing Diagrams This section describes the timing diagrams in RUN mode for each measurement mode.

ARE/CON timing 1/30 sec. 1

2

3

4

5

WO1 to WO8 WOR

1

2

3

4

2

3

Internal trigger

ANALOG OUTPUT

1

4

5 5

ON STO OFF

20ms

ON BUSY

OFF

RS-232C OUTPUT

1

4

CONT

• • •

6

160

The process is repeated every 1/30 of a second. The RS-232C output skips at a given interval. (The output cycle varies depending on the number of windows and the baud rate setting.) RS-232C data transmission is stopped when the CONT is short-circuited.