The text of a manual · part 16 of 24
CV-700 Series User's Manual: High-speed, High-accuracy, Color Vision System, pages 151 to 160
Pages 151 to 160 of 232
The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Keyence CV-070
Page 151
Chapter 4
Setting Procedure
6. Place the cursor on [SAVE] and press the [ENT] key.
SETUP SAVE CAM1 7. The saving of settings is completed. Press the [ESCAPE] key to display the environmental setting menu.
4.12.2 Comparing with the saved setting status Compare the saved setting status with the current setting status. 1. Put the CV-701(P)/751(P) into “PROGRAM” mode. 2. Hold down the [ESCAPE] key for at least two seconds.
4
The environmental setting menu appears on the screen. 3. Place the cursor on [SETUP MENU] and press the [ENT] key. The setup menu appears on the screen. 4. Place the test piece prepared in step 1 of “Saving the setting status” on the previous page into the field of view. Make sure the black rectangle is in the center of the monitor screen. Place the test piece on a flat surface so that it will not have any R. Make sure to use the same test piece used for the previous saving. The screen updates every time the [TRIG] key is pressed. 5. Compare the saved status and current status. Check the screen for the exposure and focus status. The blue lines indicate saved status, and the red lines indicate the current status. The longer bar indicates an increased exposure to light. The larger circle indicates a looser focus. Indicates the center position. The blue line indicates the saved status, and the red line indicates the current status.
Indicates the exposure status. The blue indicator shows the saved status, and the red indicator shows the current status.
SETUP SAVE CAM1
CAL AREA PINT
Indicates the focus. The blue circle indicates the saved status, and the red circle indicates the current status.
SET 00/03/30 06:41:13 NOW
Note: Be sure the black rectangle does not cover the exposure bars on the four sides of the screen. 6. Adjust all of the settings so that they will agree with the saved status. 7. The operation check of the setting status is complete. Press the [ESCAPE] key to display the environmental setting menu.
141
Page 152
Chapter 4
Setting Procedure
4.13 Initialization Initialize the settings when you want to reset all of the settings or when the CV701(P)/751(P) operates abnormally. Note 1: Initialization clears all settings to the factory-set values. Note 2: If you need to save the settings, save them in the CompactFlash memory, personal computer through the RS-232C, or take note of the necessary settings.
4.13.1 Initialization of all settings 1. Hold down the [CLEAR] key and turn on the power. The message <INIT SETTING> appears on the screen and initialization starts.
4
KEYENCE
INIT SETTING
4.13.2 Initialization by program number You can initialize the settings of one of the 16 programs from 0 to 15 by selecting the saved program number. 1. Use the [ENT] and [ESCAPE] keys to place the cursor on the [No.] of the program to be initialized.
CAM1 CAM2 PROGRAM No.00 MODE 2. Hold down the [CLEAR] key for at least two seconds. The message <ERASE SETTINGS N/Y> appears on the screen. • To cancel initialization, select [N] and press the [ENT] key. • To execute initialization, select [Y] and press the [ENT] key. CAM1 CAM2 PROGRAM No.00 MODE ARE/CON SHUTTER SCRN REG WIND•1
DATA 000000 TOL H=000000 L= 000000
ERASE SETTINGS N / Y
142
OPTION SAVE T= RAW SCR
Page 153
Chapter 4
Setting Procedure
4.14 Input/Output Operation in PROGRAM Mode Even in PROGRAM mode, the CV-701(P)/751(P) accepts a trigger input or provides a BUSY output so that the detection result and numerical value are displayed on the screen. A comparator output is not provided. Use the result and value as a test operation for adjustment. The following table lists the input/output operations in PROGRAM mode. I/O terminal/ connector Input terminal
Input connector
Signal name
Description
Status
TRG
Trigger input for timing signal
Enabled
PST
Data output selection input
Disabled
Screen registration input (Registers a REC1/REC2 screen at a TRG signal when this pin is short-circuited.)
Disabled
CI0 to CI3
Disabled
Program No. input 0 (LSB)
WI0 to WI2 Output window selection input CONT
Starts continuous operation when the program is switched without an external trigger signal.
W01 to W08 Window comparator output Output terminal
Output connector
Disabled Disabled Disabled
WOR
OR output of WO1 to WO8
Disabled
STO
Strobe signal output for output
Disabled
BUSY
BUSY signal output
Enabled
D.POLE
Position data signal output
Disabled
D0 to D12
Data output
Disabled
Note: A trigger input is not accepted in PROGRAM mode during setting procedures such as drawing a window or setting values. A trigger input is accepted only when the [TRIGGER] key on the panel keys or the remote control console can be used.
143
4
Page 154
Chapter 4
Setting Procedure
4.15 Environmental Settings The environmental settings include the display settings and external input settings. This section describes each environmental setting and the procedure for changing the settings.
4.15.1 Changing the environmental settings You can set or check the following items in the environmental settings. ➮
See page 145 for details.
1. Put the CV-701(P)/751(P) in “PROGRAM” mode. 2. Press the [ESCAPE] key for at least two seconds. The environmental setting menu appears. MEMORY CARD WHITE BALANCE SETUP MENU
4
CHANGE OUT MODE RS232C BPS RS232C OUT
CONSOLE N.O. 38400 0000000
LANGUAGE OUTPUT SYMBOL AUTO OFF TRIGGER SAVE SCR
JAPANESE COLOR OFF EXTERNAL OFF
COPY NO. AUTO SEQUENCE
No.00 OFF
CLOCK
00/03/30 06:46:46
TO No.00 NUM 4
3. Place the cursor on the desired item. 4. Press the [ENT] key. The cursor goes to the item in the right column. 5. Change the setting. •
With the panel keys Press the [▲]/[▼] cursor key.
•
With the remote control console Move the [ENT] key up or down.
6. Press the [ENT] key. The setting is confirmed. 7. Press the [ESCAPE] key to return to the PROGRAM menu.
144
Page 155
Chapter 4
Setting Procedure
4.15.2 Environmental setting list “*” indicates the initial setting value.
Parameter
Setting
Description
Function To save/readout the To sub menu. Save/read the settings and MEMORY settings and saved screen ➮ See page 171 for saved screen to/from the CARD to/from the CompactFlash details. CompactFlash memory. memory. To sub menu. To adjust the white WHITE ➮ See page 148 for Adjust the white balance. balance. BALANCE details. Save/readout the settings To sub menu. SETUP ➮ See page 140 for of focus, exposure, and To compare the settings. MENU details. reference position. Use the remote control To change the program CONSOLE* console to change the No. with the remote control program No. console. To change the program CHANGE Use the I/O connector to No. or the output window TERMINAL change the program No. or by inputting an external the output window. signal to the I/O connector during RUN mode. To output when the N.O.* Normally-open detection result is outside of the tolerance range. OUTMODE To output when the N.C. Normally-closed detection result is within of the tolerance range. To change the RS-232C 9,600/19,200/ Set the communication communication speed. BPS 38,400* speed. (No. of bits/sec.) Select the RS-232C output To select the data type RS-232C 0000000 OUT data. output by RS-232C. Use the Japanese To change the menu JAPANESE* language. display to Japanese. LANGUAGE To change the menu ENGLISH Use the English language. display to English. Displays the detection When a color monitor is COLOR* result with green, red, and used. white indicators. OUTPUT SYMBOL Displays the detection When a black-and-white MONO result with ❍, x, ? and – monitor is used. symbols. Disable automatic backlight To turn on the backlight all OFF* shut-off. the time. AUTO OFF To turn off the backlight Enable automatic backlight ON automatically. (Backlight shut-off. (CV-751(P) only) operating life: 40,000 hrs.) Execute detection at each To control detection with EXTERNAL* trigger input. external trigger input. Execute detection TRIGGER continuously without To repeat detection without INTERNAL external trigger inputs by using external trigger internally producing trigger signals in the trigger mode. signals from power-on. OFF* No screens are saved. Saves all screens ALL regardless of the detection SAVE SCR To save a screen. result. Saves the captured screen NG with an unacceptable detection result.
145
4
Page 156
Chapter 4
Setting Procedure Parameter
Setting Description Source program No. (00 to 15), Target Set the source and target program No. COPY NO. program Nos. and select (00 to 15) OK to copy. ➮ See page 146 for the setting. OFF Set the program Nos. for sequential operation. (MODE1) ➮ See page 147 for AUTO SEQUENCE the setting. Set the program Nos. for sequential operation. (MODE2)
CLOCK
Calendar input
Function To copy the settings of one program No. to another program No. Normal operation To execute several program Nos. sequentially with one trigger signal. To execute several program Nos. sequentially with one trigger signal. The position adjustment function and the starting No. use common data.
Input the present time and To adjust the calendar. date.
4 4.15.3 Useful functions Automatic backlight shut-off [AUTO OFF] (CV-751(P) only) Turns off the backlight of the monitor automatically. To activate this function, place the cursor on [AUTO OFF] in the environmental setting menu and select “ON”. (The backlight has an operating life of 40,000 hours.) •
The backlight is turned off under the following conditions: 10 or more minutes have passed since the last key operation, detection of results outside of the tolerance range, or message appearances on the screen.
•
The backlight is turned on again when one of the following occurs: Any key is pressed. A control signal is input from the external devices through RS-232C. The detection result goes outside of the tolerance range. A message appears on the screen.
Copying the program number [COPY NO.] The settings of one program number can be copied to another program number. 1. Place the cursor on [COPY NO.] and press the [ENT] key. The cursor goes to the source number field. 2. Press the [▲]/[▼] cursor keys or move the [ENT] key up or down to select the source program number and press the [ENT] key. The cursor goes to the target number field. 3. Press the [▲]/[▼] cursor keys or move the [ENT] key up or down to select the target program number and press the [ENT] key. The cursor goes to [OK?]. 4. Press the [ENT] key to copy the settings. When the [ESCAPE] key is pressed at any time during the procedure, the cursor returns to [COPY NO.].
146
Page 157
Chapter 4
Setting Procedure
Sequential operation [AUTO SEQUENCE] Executes the operations of several programs sequentially with one trigger signal by automatically switching the program numbers. The limitations below are placed on the first program number. Up to four programs starting from the first program number can be sequentially processed. (➮ See page 164 for the timing diagrams. ) Note 1: The first program number can be set with the I/O terminal/connector when [CHANGE] in the environmental setting menu is set to [TERMINAL]. Note 2: The CV-701(P)/751(P) bypasses the program number under [ARE/CON] mode and unused program numbers. e.g.) When the number for [AUTO SEQUENCE] processing is set to 4 with the following settings, only program No. 0 will be processed. No.0: [ABS. POS] No.1/2/3: [ARE/CON] Setting parameters OFF AUTO SEQUENCE
MODE1 MODE2
2 Num
4
3 4
The [Num] in the setting parameters indicates the number of programs to be processed sequentially. <e.g.> When the first program number is set to No.4 and [Num] is set to 2, program Nos. 4 and 5 are processed sequentially. <Requirements for the first program number> [Num]=2: The first program numbers can be selected from 2n (0, 2, 4, 6, 8, 12, 14) only. [Num]=3/4: The first program numbers can be selected from 4n (0, 4, 8, 12) only. Note: When the selected first program number does not satisfy the requirements, the [AUTO SEQUENCE] function is not activated and only the selected program number will be processed. Tips
When a trigger signal is input and the CV starts processing, the display is fixed to the screen of the first program number. 1. Set the program numbers in advance for sequential operation. 2. Place the cursor on [AUTO SEQUENCE] and press the [ENT] key. The cursor goes to [OFF]. 3. Press the [▲]/[▼] cursor key to set the parameters for [AUTO SEQUENCE]. MODE2
Executes the operations of several programs sequentially at one trigger signal. Up to four programs can be processed. The position adjustment function uses the data of the first program number to process the other programs.
MODE1
Executes the operations of several programs sequentially at one trigger signal. (Up to four programs can be processed.)
OFF
Executes normal operation.
Note: When the AUTO SEQUENCE is set to MODE2, the CV processes programs of [INS+POS] mode.
147
Page 158
Chapter 4
Setting Procedure 4. Press the [ENT] key. The cursor goes to “2”. 5. Press the [▲]/[▼] cursor key to select the value for [Num]. 6. Press the [ENT] key and return to the environmental setting menu.
Adjusting the white balance Adjust the image using the actual illumination for detection so that white objects are projected in white. Adjustments of the white balance are required every time the targets and illumination are changed. 1. Place the cursor on [WHITE BALANCE] and press the [ENT] key. The adjustment menu appears on the screen. • A frame and message “REGISTER WHITE T” appears on the screen. Place a sheet of white paper in front of the camera. • The screen updates with every trigger signal input.
4
WHITE BALANCE
SET CAM1 R= 027 G= 017 B= 024
REGISTER WHITE T
2. Place the cursor on [SET] and press the [ENT] key. The white balance for camera 1 is adjusted.
SET CAM1 3. Press the [ESCAPE] key to return to the environmental setting menu when only one camera is connected. When two cameras are connected, go to step 4. 4. Place the cursor on [CAM1] and press the [ENT] key. [CAM2] is selected and the adjustment menu for camera 2 appears. • A frame and message “REGISTER WHITE T” appears on the screen. Place a sheet of white paper in front of the camera. • The screen updates with every trigger signal input.
SET CAM1 5. Place the cursor on [SET] and press the [ENT] key. The white balance for camera 2 is adjusted.
SET CAM2 6. Press the [ESCAPE] key to return to the environmental setting menu.
148
Page 159
Chapter 4
Setting Procedure
Adjusting the clock Adjust the time and date of the clock built into the CV-701(P)/751(P). 1. Place the cursor on [CLOCK] and press the [ENT] key. The digit of the year is shown as highlighted. You can adjust the setting. The time and date are displayed as follows: Year/Month/Date Hour/Minute/Second COPY NO. AUTO SEQUENCE
CLOCK 2. Move the cursor to the right and left to select the digit to be changed. CLOCK
00/04/07 12:49:57
3. Press the [▲]/[▼] cursor key or move the [ENT] key up/down repeatedly. CLOCK
00/07/07 12:49:57
4
•
With the panel keys Press the [▲] cursor key repeatedly.
•
With the remote control console Press the [ENT] key up repeatedly. The value increments, and after “9” the second digit is incremented. Every time the [▼] cursor key is pressed or the [ENT] key is held down, the value decrements to “0”.
4. Press the [ENT] key. The setting is confirmed. 5. Press the [ESCAPE] key to return to the environmental setting menu. Note: “Second” cannot be adjusted.
Setting the RS-232C output data Select the format of data to be output with RS-232C communication. ➮
See page 182 for data formats.
RS-232C OUT 0 0 0 0 0 0 0 0 The numbers indicate (from the left): Data 0: Output setting of judgment result Data 1: Output setting of number of pixels Data 2: Output setting of the measured value [INS] mode Data 3: Output setting of X coordinate Data 4: Output setting of Y coordinate Data 5: Output setting of correlation ratio Data 6: Output setting of rotation angle
(0: OFF, 1: ON) (0: OFF, 1: ON) (0: OFF, 1: ON) (0: OFF, 1: ON) (0: OFF, 1: ON) (0: OFF, 1: ON) (0: OFF, 1: ON)
All settings are factory-configured to 0. Tips
1. Place the cursor on [RS-232C OUT] and press the [ENT] key. The first digit is shown as highlighted. You can change the settings. RS232C BPS RS232C OUT
38400 0000000
2. Move the cursor to the right and left to select the digit to be set. RS232C BPS RS232C OUT
38400 1000000
149
Page 160
Chapter 4
Setting Procedure 3. Press the [▲]/[▼] cursor key or move the [ENT] key up or down to change the value. 4. Press the [ENT] key after setting all digits. The CV returns to the environmental setting menu.
4
150