BL-V35E Instruction Manual: Bar Code Display Interface: Appendix

Pages 143 to 156 of 156, from BL-V35E Instruction Manual: Bar Code Display Interface

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Keyence BL-V35E

Page 143

Appendix The appendix describes the outer dimensions, factory default settings and BLV35E error screens.

Appendix 1. Specifications ....................................................... 134 Appendix 2. Dimensions ........................................................... 135 Appendix 3. PLC Link Program Examples ............................... 136 Appendix 4. Error Display List .................................................. 139 Appendix 5. ASCII Code Table .................................................. 140 Appendix 6. Setting Parameter List .......................................... 141 Appendix 7. List of Settings at Shipment ................................ 144 Appendix 8. Index ...................................................................... 145

Page 144

Appendix

Appendix 1.

Specifications This section provides the specifications of the BL-V35E main unit. Model Number of saved data presets Memory backup Parallel interface

Serial interface

Input 1. (7 points) Output (12 points) • OK output (verification OK) • NG output (verification NG) • OUT1 to OUT10 output (output No.) • Serial port 1 (for connection of external unit 2. or bar code reader) • Serial port 2 (dedicated to connection of bar code reader)

External power supply for bar code reader Ambient operating Environtemperature mental resistance Ambient operating humidity Operating atmosphere Vibration resistance Rating

Supply voltage Power consumption

Appendix

Weight Basic functions

BL-V35E 399 maximum Lithium battery (service life: approx. 10 years at 25°C) No-voltage input (with/without contact) Output format NPN open connector output Rated load

30 VDC, 100 mA

Leak current at OFF

0.1 mA or less

Residual voltage at ON Less than 1 V Applicable standard Synchronization method Transmission code Baud rate

Data bit length Parity check Stop bit length 5 V ± 5%, 750 mA max.

In conformance to EIA RS-232C Start-stop method (full duplex) ASCII code 600, 1200, 2400, 4800, 9600, 19200, 31250 or 38400 bits 7 or 8 bits None, odd or even 1 or 2 bit

0 to 50°C 35 to 85%RH Free from dust and corrosive gas 10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of X, Y and Z directions 100 to 120 VAC, 50/60 Hz 20 VA Approx. 600 g The bar code data verifier BL-V35E stores (presets) up to 399 types of bar code data, and compares them to the bar code data read by a bar code reader connected to the BL-V35E. When the readout data matches the preset data, the BL-V35E outputs the output No. assigned to the matching preset data using a bit, binary value or BCD number from the parallel port.

1. There are timing inputs (2 points) to bar code readers connected to serial ports 1 and 2 and inputs (5 points) to effect the operations assigned to the main keys ([PRESET], ▼ , ▲ , [CANCEL] and [ENTER]). 2. A personal computer, programmable controller (PLC) or printer (DPU-414 manufactured by SEIKO DENSHI KOGYO) can be connected.

134

Page 145

Appendix

Dimensions The outline drawing below shows the outer dimensions of the BL-V35E main unit. 10.5

10.5 192

67.5

150 1

10

51 1.6 to 6 mm*

90

4-ø5 (mounting hole)

(40)

110 98 96

100 to 120 VAC (with plug) Code length: 2 m *

The resin panel thickness must be 3 mm or more.

186

Pane cut size 92 +0.8 0

188 +10

The panel thickness must be 6 mm or less.

Appendix

Appendix 2.

135

Page 146

Appendix

Appendix 3.

PLC Link Program Examples In the programs below, the readout data is written after D105 (DM105). Perform processing according to your application. ● Settings in the BL-V35E • ”PLC Tim Area” is set to “ON”. •

”DM Address” is set to “0000”.

● Handling of the data write flag: Sequence processing In this program example, processing using the “+02 timing input response area” to confirm whether the BL-V35E has recognized the “+01 read timing area” normally is not performed. ■ In the case of the MELSEC-A series M9038 MOV

K100

D0

Specifies the head address of the data write destination.

MOV

K2

D100

Writes “2” to the data write flag. (The sequence processing is used to handle the flag.)

MOV

K1

D1

MOV

K0

D1

XO XO

LD=

D100

K3

Performs program processing of data written in D105 and later.

MOV

K2

Appendix

END

136

D100

Sets “X0” to the read timing input.

Performs the specified program processing when D100 becomes “3”. Writes “2” to D100 when processing is completed.

Page 147

Appendix ■ In the case of the SYSMAC-C series 25315 (A50015)

0000

MOV #0064 DM0000

Specifies the head address of the data write destination (DM100). Enters a binary value into a DM because the BL-V35E processes the data as binary data.

MOV #0002 DM0100

Writes “2” to the data write flag. (The sequence processing is used to handle the flag.)

MOV #0001 DM0001 Sets “0000” to the read timing input.

0000

MOV #0000 DM0001

25313 (A50013)

CMP DM0100 #0003 Performs the specified program processing when DM0100 becomes “3”. Writes “2” to DM0100 when processing is completed.

25506 (A50006) Performs program processing of data written in D105 and later.

MOV #0002 DM0100 *

( ) indicates the case in which the CV series is used.

Appendix

END

137

Page 148

Appendix ■ In the case of the KV series

2008

Specifies the head address of the data write destination.

#0002 <DW> DM0100

Writes “2” to the data write flag. (The sequence processing is used to handle the flag.)

#0001 <DW> DM0001

0000

#0000 <DW> DM0001

0000

2002

#0100 <DW> DM0000

DM0100 <LDA>

#0003 <CMP>

2010 Performs program processing of data written in D105 and later.

#0002 <DW> DM0100 END

Appendix

ENDH

138

Sets “0000” to the read timing input.

Performs the specified program processing when DM0100 becomes “3”. Writes “2” to DM0100 when processing is completed.

Page 149

Appendix

Error Display List This section describes BL-V35E error messages. •

This error occurs when the memory of the main RAM is lost or when incorrect data is saved. B a c k U p CHECK e r r C l ea r t o I n i t

•

This error occurs when the memory of the main RAM is lost or when incorrect data is saved. P r e s e t CHECK e r r C l ea r =A l l C l ea r

•

When the [CLEAR] key is pressed, the error status is reset and all settings are initialized to the factory default values.

This error occurs when the send buffer capacity (99 pieces of data) is insufficient for the data to be stored (➮ See p. 102). Send Bu f f e r Ov e r C l ea r t o Re s e t

•

When the [CLEAR] key is pressed, the error status is reset.

E r r o r Re s e t

This error occurs when data with more than 32 digits is received as bar code data. The error status is reset when correct data Ba r Code Da t a with 32 digits or less is received. 32By t e

•

When the [CLEAR] key is pressed, the error status is reset and all data stored in the send buffer is cleared.

This error occurs when the PLC link is not performed correctly. PLC L i n k C l ea r t o

•

When the [CLEAR] key is pressed, the error status is reset and all settings are initialized to the factory default values.

This error occurs when the memory of the main RAM is lost or when incorrect data is saved. Re f Da t a E r r C l ea r =A l l C l ea r

•

When the [CLEAR] key is pressed, the error status is reset and all settings are initialized to the factory default values.

Ov e r

This error occurs when the serial No. target digits are not set correctly. Ve r i f y Se r i a l Se t t i ng E r r o r

No

After the error message is displayed for a while, the BL-V35E automatically enters set mode.

Note: While “18 NG Output” in the option set mode is set to “1) At Error”, the NG output in the parallel interface turns ON when an error occurs (except when the message “Bar Code Data 32 Byte Over” or “Serial No Digit Setting Error” is displayed).

139

Appendix

Appendix 4.

Page 150

Appendix

Appendix 5.

ASCII Code Table The table below shows ASCII codes.

High-order 4 bits Hexadecimal

0

1

2

3

4

5

6

7

Appendix

Low-order 4 bits

Binary 0000 0001 0010 0011 0100 0101 0110 0111

140

0

0000

DLE (SP)

0

@

P

' p

1

0001 SOH DC1

!

1

A

Q a q

2

0010 STX DC2

”

2

B

R b r

3

0011 ETX DC3

#

3

C

S c s

4

0100 EOT NAK

$

4

D

T d t

5

0101 ENQ DC4

%

5

E

U e u

6

0110 ACK SYN

&

6

F

V f v

7

0111 BEL ETB

’

7

G

W g w

8

1000 BS CAN

(

8

H

X h x

9

1001 HT

EM

)

9

I

Y i y

A

1010 LF

SUB

✽

:

J

Z j z

B

1011 HM ESC

+

;

K

[ k

{

C

1100 CL

,

<

L

\

I

D

1101 CR

–

=

M

]

M

}

E

1110 SO

.

>

N n

~

F

1111 SI

/

?

O o del

_

Page 151

Appendix

Setting Parameter List The table below shows the setting parameters available in the BL-V35E, ■ Communication settings for serial port 1 Port 1 Baud ( )bit/s Port 1 Form Data length: 7 or 8 Connect ❏ PC Unit

Parity check: n, e or o Send Form

Send Data

Protocol

RTS/CTS Rcv 1 Timer Enter Key= ❏ BL Reader

Send Form

Rcv 1 Timer ❏ PLC Link

Connected PLC

Station No./PLC Unit No. Support Unit Block No. DM Address PLC Tim Area Enter Key= ❏ Printer

Auto Print

Auto Print=

❏ Port 2 Direct

Rcv 1 Timer Direct Read Enter Key=

Stop bit length: 1 or 2 ❏ No Sending ❏ stx+[data]+etx ❏ [data]+CR ❏ [data]+CRLF ❏ esc+[data]+CR ❏ esc+[data]+CRLF ❏ Bar Code Data ❏ Preset No. ❏ Out No. ❏ Ref Data ❏ No Handshaking ❏ PASS/RTRY ❏ ACK/NAK ❏ OFF ❏ ON ❏ Infinite ( )S ❏ Out Port 1 ❏ Out OFF ❏ stx+[data]+etx ❏ [data]+CR ❏ esc+[data]+CR ❏ Infinite ( )S ❏ MELSEC-A ❏ SYSMAC-C ❏ KEYENCE KV ( ) ❏ Data Register ❏ File Register ( ) ( )OO ❏ OFF ❏ ON ❏ Out Port 1 ❏ Out OFF ❏ OFF ❏ OK only ❏ NG only ❏ ON ❏ No. + Data ❏ No. only ❏ Data Only ❏ Infinite ( )S Port 2 Port 1, 2 ❏ Out Port 1 ❏ Out OFF ❏ Out Port 2

141

Appendix

Appendix 6.

Page 152

Appendix ■ Communication settings for serial port 2 Port 2 Baud Data Form Receive Form Rcv 2 Timer

( )bit/s Data length: 7 or 8 ❏ stx+[data]+etx ❏ [data]+CR ❏ esc+[data]+CR ( )S

Parity check: n, e or o

Stop bit length: 1 or 2

❏ Normal

❏ Out

❏ Bit ❏ Binary ❏ BCD

❏ Active ❏ Verify Step ❏ Serial No.

No. Direction

❏ Forward ❏ Reverse ( ) ( ) ( ) ❏ Reset ❏ Continue ❏ Repeat

■ Main settings Mode Setup

Start Digit Max Digits No. Change No. Protect

Max Preset No. AutoIncrement Counter

❏ ON ❏ OFF ❏ ON

Counter Mode 1 Counter Mode 2 Counter Mode 3

❏ Reset @ OFF ❏ Hold @ OFF ❏ Reset @ Preset ❏ Hold @ Preset ❏ Reset @ Print ❏ Hold @ Print

❏ OFF

Appendix

* The parameters “Max Preset No.”, “AutoIncrement” and “Counter” are available while “Mode Setup” is not set to “Serial No.”

142

Page 153

Appendix ■ Optional settings ❏ ON ❏ OFF ❏ Forward

❏ Key Only

❏ Reverse Key (Preset) Key (Cancel) Key (Enter) Input (Preset) Input (Cancel) Input (Enter) Input Type Input Time Input User Out ON Timer Out Delay OUT1-10 User NG Output Preset Output

❏ 0 sec ❏ 1 sec ❏ 0 sec ❏ 1 sec ❏ 0 sec ❏ 1 sec ❏ 0 sec ❏ 1 sec ❏ 0 sec ❏ 1 sec ❏ 0 sec ❏ 1 sec ❏ N.O. ❏ N.C. ( )ms ❏ IN 5 ❏ IN 4 ( )ms ( )ms ❏ OUT10 ❏ OUT9 ❏ OUT5 ❏ OUT4 ❏ At Verify NG ❏ At Error ❏ OFF ❏ ON at Update ❏ ON in Preset

❏ OFF

Max. Digits Start Digit Max. Digits Start Digit ❏ 3 sec ❏ 3 sec ❏ 3 sec ❏ 3 sec ❏ 3 sec ❏ 3 sec

( ( ( ( ❏ 5 sec ❏ 5 sec ❏ 5 sec ❏ 5 sec ❏ 5 sec ❏ 5 sec

) ) ) ) ❏ OFF ❏ OFF ❏ OFF ❏ OFF ❏ OFF ❏ OFF

❏ IN 3

❏ IN 2

❏ IN 1

❏ OUT8 ❏ OUT3

❏ OUT7 ❏ OUT2

❏ OUT6 ❏ OUT1

Appendix

Beep Digit Specify

143

Page 154

Appendix

Appendix 7.

List of Settings at Shipment The tables below shows the BL-V35E settings at the time of shipment. ■ Communication settings for serial port 1 Port 1 Baud Port 1 Form Connect Unit

9600 bits/s 7e1 (data length: 7 bits, parity check: even, stop bit length: 1 bit) PC Send Form [data]+CR Send Data Bar Code Data Protocol No Handshaking RTS/CTS OFF Rcv 1 Timer 5.0 s Enter Key= ut Port 1

■ Communication settings for serial port 2 Port 2 Baud Port 2 Form Receive Form Rcv 2 Timer

9600 bits/s 7e1 (data length: 7 bits, parity check: even, stop bit length: 1 bit) [data]+CR 5.0S

■ Main settings Mode Setup Out Max Preset No. AutoIncrement Counter

Normal Bit 10 ON OFF

■ Optional settings

Appendix

Beep Digit Specify Key (Preset) Key (Cancel) Key (Enter) Input (Preset) Input (Cancel) Input (Enter) Input Type Input Time Input User Out ON Timer Out Delay OUT 5-1 User OUT 10-6 User NG Output Preset Output

144

ON OFF 0 sec 0 sec 0 sec 0 sec 0 sec 0 sec N.O. 10 ms 00000 (No input is released.) 500 ms 5 ms 00000 00000 (No output is released.) At Verify NG OFF

Page 155

Appendix

Appendix 8.

Index

A

Digit designation function .................................................. 68 Digit designation start digit ................................................ 68

ACK/NAK protocol ........................................................... 101 All data printout ............................................................... 131 Alternative input .................................................................. 6 Alternative read ................................................................... 6 ASCII code ...................................................................... 130 Application of digit designation function to preset function 70

Dimensions ..................................................................... 135 Direct communication .................................................. 10, 89 Direct control of parallel I/O ............................................... 73 DM assignment in PLC link when the serial No. check function is used ............................................................. 120

Attachment ........................................................................ 20

DM assignment in PLC link when the step verification function is used ............................................................. 120

Automatic increment function ...................................... 33, 92

DM head address ............................................................ 116

Automatic printout format ................................................ 128 Automatic printout function .............................................. 128 Automatic printout timing ................................................. 128 Automatic printout when the serial No. check function is used ........................................................................... 130 Automatic printout when the step verification function is used ........................................................................... 129

B Baud rate ........................................................................... 85 BCD number output .......................................................... 45 Binary value output ........................................................... 45 Bit output ........................................................................... 45 Block No. ................................................................... 88, 113

C Command communication .............................................. 100 Command list .................................................................. 104 Communication protocol ........................................... 86, 101 Communication time in PLC link ..................................... 122

I Initialization mode ............................................................. 97

K Key input method .............................................................. 61 Key protect ........................................................................ 95

M Main set mode ................................................................... 91 Manual printout function .................................................. 129 Monitor mode .................................................................... 17 Multi-preset function ...................................................... 4, 32

N NG output selection ........................................................... 96 No handshaking .............................................................. 101 Number of data presets ............................................... 33, 92

Communication set mode for serial port 1 ........................ 84

O

Connectable unit ................................................................. 8

OK/NG output delay time ............................................ 45, 96

Connection of bar code reader ......................................... 25

One data printout ............................................................ 131

Connection of external unit ............................................... 27

Option set mode ................................................................ 94

Connection of two BL-V35E units ..................................... 28

Output data type ............................................................. 102

Copying settings between two BL-V35E units .................. 74

Output data when the serial No. check function is used . 103

Counter function ................................................................ 42

Output data when the step verification function is used .. 103

Counter value input ........................................................... 43

Overview of functions of BL-V35E ...................................... 4

Counter value reset ..................................................... 43, 44

P D

Parallel input ..................................................................... 64

Data communication ....................................................... 100

Parallel input polarity ......................................................... 95

Data format ....................................................................... 85

Parallel input time constant ............................................... 96

Data reference function ..................................................... 66

Parallel output format ........................................................ 45

Data write destination area ............................................. 116

Parallel output ON time ............................................... 45, 96

Data write head area ....................................................... 116

PASS/RTRY protocol ...................................................... 101

Device assignment .......................................................... 116

PLC available in link ........................................................ 112

Digit designation direction ................................................. 68

PLC link ........................................................................... 112

Digit designation effective digits ........................................ 68

PLC link error .................................................................. 133

145

Appendix

Communication set mode for serial port 2 ........................ 90

Page 156

Appendix

PLC link program example .............................................. 136 PLC timing area ........................................................ 88, 117 Printout function .............................................................. 126 Procedure for selecting preset data to be verified by the preset active function ...................................................... 48 Preset-active function ........................................................ 46 Preset wild card function ................................................... 39 Procedure for confirming preset data ................................ 41 Procedure for deleting preset data .................................... 38 Procedure for entering preset data from any preset No. ... 37 Procedure for entering preset data using key operation ... 35 Procedure for saving preset data ...................................... 33

R Real-time processing ...................................................... 118 Receive format ............................................................ 87, 90 Release of parallel I/O to outside ...................................... 73 RTS/CTS protocol ..................................................... 86, 102 RUN mode ........................................................................ 39

S Selection of preset output ................................................. 96 Send buffer ........................................................................ 84 Send data .......................................................................... 86 Send format ............................................................... 86, 102 Serial No. check function .................................................. 54 Serial No. direction ............................................................ 55 Serial No. effective digits ................................................... 55 Serial No. increment .......................................................... 56 Serial No. protect .............................................................. 57 Serial No. start digit ........................................................... 55 Serial port 1 receive timer ................................................. 86 Serial port 2 receive timer ................................................. 90

Appendix

Serial communication ...................................................... 100 Serial communication command ..................................... 104 Step verification function ................................................... 50 Set mode ........................................................................... 80 Set mode start procedure .................................................. 80 Set mode exit procedure ................................................... 82 Setting initialization procedure .......................................... 97 Setting of serial communication ...................................... 100 Setting with setting software ............................................. 14 Setting with the BL-P1E .................................................... 15 Sequence processing ..................................................... 118 Shift key function description label ...................................... 3 Specifications .................................................................. 124 Supported device ...................................................... 88,113

146

W Wiring of parallel interface ................................................. 23 Wiring of serial interface .................................................... 25 When using two bar code readers ...................................... 8