For the Keyence BL-V35E

Page 133

Chapter 9 Printout Function This chapter describes how to connect a printer to the BL-V35E, print the readout bar code data and set the printing parameters.

9.1

Overview of the Printout Function .................................. 124

9.1.1 Overview of the printout function ......................................... 124 9.1.2 Connection and setting during printout ................................ 124 9.2

Automatic Printout Function ........................................... 126

9.2.1 Setting the operation of the automatic printout function ...... 126 9.2.2 Automatic printout when the step verification function is used .............................................................................. 127 9.2.3 Automatic printout when the serial No. check function is used .............................................................................. 128 9.3

Manual Printout Function ................................................ 129

9.3.1 Operation of the manual printout function ............................ 129 9.3.2 Performing manual printout ................................................. 130

Page 134

Chapter 9

9.1

Printout Function

Overview of the Printout Function This section provides an overview of the printout function in the BL-V35E.

9.1.1 Overview of the printout function When the serial printer DPU-414 manufactured by SEIKO Instruments Inc. is connected to the BL-V35E, preset data, output Nos. and readout data can be printed out. Automatic printout and manual printout are available as printout methods. ■ Automatic printout function While the serial printer DPU-414 is connected to serial port 1, bar code data can be automatically printed out as soon as the bar code data is read (or the [ENTER] key is pressed). Note: When the counter function is used, the counter value is also printed out. When the data reference function is used, the reference data is also printed out. ■ Manual printout function Data can be printed out according to the specified key operation. The following two types are available. •

One data printout One readout data currently displayed on the LCD display is printed out.

•

All data printout All currently saved preset data is printed out.

9.1.2 Connection and setting during printout Before printing, connect and set up the BL-V35E and a printer as described below. ■ Connection Connect serial port 1 of the BL-V35E to the serial connector of the printer DPU414. For the connection cable, see p. 27. ■ Setting • BL-V35E In communication set mode for serial port 1 (➮ See p.85 and 89), change the settings as follows. • Align the baud rate and data format (data length, parity and stop bit length) with the printer’s settings.

9

•

Set “Connect Unit” to “Printer”.

•

When using the automatic printout function, set the automatic printout timing and the automatic printout format.

Note: If “Connect Unit” is not set to “Printer”, “Auto Print (automatic printout timing)” and “Auto Print= (automatic printout format)” are not displayed.

124

Page 135

Chapter 9 Printout Function •

Printer (DPU-414) Set the software DIP switch of the printer DPU-414 as follows. For the setting procedure, refer to the DPU-414 Instruction Manual. Align the baud rate and data format (data length and parity) with the BL-V35E’s settings. (9600, 7, E, 1 shown below.) [DIP SW setting mode] Dip SW-1 1 (OFF) : Input = Serial 2 (ON) : Printing Speed = High 3 (ON) : Auto Loadings = ON 4 (OFF) : Auto LF = OFF 5 (ON) : Setting Command = Enable 6 (OFF) : Printing 7 (ON) : Density 8 (ON) : = 100% Dip SW-2 1 (ON) : Printing Columns = 40 2 (ON) : User Font Back-up = ON 3 (ON) : Character Select = Normal 4 (ON) : Zero = Normal 5 (ON) : International 6 (ON) : Character 7 (ON) : Set 8 (OFF) : = U.S.A. Dip SW-3 1 (OFF) : Data Length = 7 bits 2 (OFF) : Parity Setting = Yes 3 (OFF) : Parity Condition = Even 4 (ON) : Busy Control = H/W Busy 5 (OFF) : Baud 6 (ON) : Rate 7 (ON) : Select 8 (ON) : = 9600 bps

Note: The stop bit length of the printer DPU-414 is fixed to “1”.

9

125

Page 136

Chapter 9

9.2

Printout Function

Automatic Printout Function By using the automatic printout function, data can be printed out one at a time when a bar code is read in RUN mode or the [ENTER] key is pressed.

9.2.1 Setting the operation of the automatic printout function When the automatic printout function is used, the printer performs the following operation. Perform each setting in communication set mode for serial port 1 (➮ See p. 89). ■ Automatic printout timing Automatic printout can be performed at the following four timing intervals. OFF : Disables the automatic printout function. OK Only : Prints out the data every time OK is output. NG Only : Prints out the data every time NG is output. ON : Prints out the data every time OK or NG is output. ■ Automatic printout format The following three formats are available for automatic printout. No. + Data : Prints out the preset No., the output No. and the readout data. No. Only : Prints out the preset No. and the output No. Data Only : Prints out the readout data.

Output examples • In the case of “No. + Data” format Preset No.

No.002(001)

Output No.

KEYENCE002

Readout data

• In the case of “No. + Data” format *

When the reference data is set and the counter function is set to ON

No.003 (003)

Count=

21

Counter value

KEYENCE003 Reference data

• In the case of “No. Only” format

9

No.004 (004)

• In the case of “Data Only” format KEYENCE007

126

Page 137

Chapter 9 Printout Function

9.2.2 Automatic printout when the step verification function is used When the step verification function is used, the printer performs the following operation. ■ Automatic printout timing • Available timing intervals are equivalent to those available in the normal RUN mode. •

Data is printed out when reading of the second data is completed.

■ Automatic printout format Output examples • In the case of “No. + Data” format Preset No. + Output No. + Readout data (reference data)

49401387

Preset No. and output No. matched by reading the first data First readout data

(Chocolate)

First reference data (only when it is set)

49401387

Second readout data

No.001(001)

OK

Count =

306

Counter value

Result of verification between the first readout data and the second readout data

Note: When the preset data has been entered in advance, only the first readout data is compared to the preset data. (A parallel output is not given.) Accordingly, the preset No. (output No.), the reference data and the counter value are printed out. •

In the case of “No. Only” format Preset No. + Output No. No.001(001) OK

Count =

306

Preset No. and output No. matched by reading the first data Counter value

Result of verification between the first readout data and the second readout data

•

In the case of “Data Only” format Readout data (reference data)

49401387

First readout data

(Chocolate)

First reference data (only when it is set)

49401387

Second readout data

OK

Count =

306

9

Counter value Result of verification between the first readout data and the second readout data

127

Page 138

Chapter 9

Printout Function

9.2.3 Automatic printout when the serial No. check function is used When the serial No. check function is used, the printer performs the following operation. ■ Automatic printout timing • Available timing intervals are equivalent to those available in the normal RUN mode. ■ Automatic printout format Output examples • In the case of “No. + Data” format Result of serial No. check + Readout data Result of serial No. check

OK Count = 000000 OK Count = 000001 OK Count = 000002 OK Count = 000003 NG 000009 NG 000005 OK Count = 000004

•

1

Counter value Readout data

2 3 4

5

In the case of “No. Only” format Result of serial No. check Result of serial No. check

OK OK OK OK NG NG NG OK

9 •

Count = Count = Count = Count =

1 2 3 4

Count =

5

Counter value

In the case of “Data Only” format Readout data Readout data

000000 000001 000002 000003 000005 000009 000004

128

Page 139

Chapter 9 Printout Function

9.3

Manual Printout Function By using the manual printout function, data can be printed out according to the specified key operation.

9.3.1 Operation of the manual printout function ■ Manual printout type The following two manual printout types are available. •

One data printout One readout data currently displayed on the LCD display is printed out.

•

All data printout All currently saved preset data is printed out.

■ Manual printout format The following six formats are available for manual printout. • Print One Data

: No. + Data: Prints out the preset No., the output No. and the readout data currently displayed.

• Print One Data

: No. Only: Prints out the preset No. and the output No. currently displayed.

• Print One Data

: Data Only: Prints out only the readout data currently displayed.

• Print All Data

: No. + Data: Prints out all preset Nos., all output Nos. and all preset data.

• Print All Data : No. Only : Prints out all preset Nos. and all output Nos. • Print All Data: Data Only : Prints out all preset data. Note 1: Even while the step verification function is being used, manual printout is enabled if the preset data has been entered in advance. Note 2: When the serial No. check function is used, manual printout is disabled.

Output example In the case of “Print All Data: No. + Data” No.000 (NG) (preset NG) No.001 (001) KEYENCE001 No.002 (001) KEYENCE002 No.003 (003) KEYENCE003

Count=

4

Count=

1

Count=

1

Count=

21

Count=

2

9

The preset No. 0 indicates that the verification result is NG.

(KYENCE BL-V35E)

No.004 (004) KEYENCE004

129

Page 140

Chapter 9

Printout Function

9.3.2 Performing manual printout Procedure 1. Press the [OPTION] key in RUN mode. The format last selected is displayed, and the LED above the [OPTION] key illuminates.

PRESET

1 TIM 1 TIM 2 4 3 2 1 OUT

P r i n t 1 Da t a 0 ) No . +Da t a

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

0

BL-V35E

PROGRAM

Printout format currently selected

2. Select the format. When the ▼ or ▲ key is pressed, the printout format is switched. Press and hold the ▼ or ▲ key until a desired format is displayed. The printout format is switched.

PRESET

1 TIM 1 TIM 2 4 3 2 1 OUT

P r i n t 1 Da t a 1 ) No . o n l y

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

8 7 6 5 OK 10 9 NG

PRESET

CANCEL

ENTER

KEYENCE

PROGRAM MONITOR

BL-V35E

Select a desired format using these keys.

3. Press the [ENTER] key. Printout is started.

PRESET

1 TIM 1 TIM 2 4 3 2 1 OUT

S t a r t C l ea r

P r i n t t o Ca n c e l

PRESET No.

DATA

COUNT

SHIFT SYMBOL

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

8 7 6 5 OK 10 9 NG

9

PRESET

KEYENCE

Printout is started by pressing this key.

130

CANCEL

ENTER

PROGRAM MONITOR

BL-V35E

Page 141

4. To abort printout, press the [CLEAR] key.

PRESET

TIM 1 TIM 2 4 3 2 1 OUT

S t a r t P r i n t Ca n c e l e d

PRESET No.

DATA

COUNT

SHIFT ABC..

OPTION

BACK SPACE

7

8

9

4

5

6

1

2

3

0

CLEAR

PROGRAM

MONITOR

8 7 6 5 OK 10 9 NG

PRESET

KEYENCE

CANCEL

ENTER

BL-V35E

Note: The setting contents selected using the [OPTION] key are backed up in the memory. When performing the same printout, press the [OPTION] and [ENTER] keys alternately.

Page 142

Chapter 9

9

132

Printout Function